The garden jet pump (also known as a shallow well jet pump) is a self-priming centrifugal pump equipped with an ejector assembly that enables it to draw water from depths up to 8 meters (25 feet) – making it ideal for shallow wells, rainwater tanks, cisterns, or surface water sources. Unlike standard centrifugal pumps that require a flooded suction, the jet pump can be located above the water source and will automatically prime itself, pulling water up from the supply.
This pump is the workhorse for domestic water supply, garden irrigation, lawn sprinkler systems, and pressure boosting applications where the water source is above ground level. Its compact design, quiet operation, and integrated pressure switch and small pressure tank allow automatic start/stop based on demand – providing convenience and water efficiency.
The jet pump uses a Venturi ejector to create suction:
The motor drives an impeller, creating high‑velocity water flow.
Part of this flow is diverted through a nozzle into the ejector, which creates a low‑pressure zone.
The low pressure draws water up from the well or tank through the suction line.
The two streams mix and enter the impeller eye, where the pump adds more pressure.
Water is discharged to the house tap or garden hose.
Because the ejector is built into the pump housing (or mounted at the well for convertible jet pumps), the garden jet pump can self‑prime – clearing air from the suction line without manual filling.
| Parameter | Typical Range |
|---|---|
| Flow range | 1.5 – 5.0 m³/h (25 – 85 L/min) |
| Maximum head (pressure) | 30 – 50 m (100 – 165 ft) |
| Suction lift | Up to 8 m (25 ft) – at sea level |
| Motor power | 0.5 – 1.5 HP (0.37 – 1.1 kW) |
| Voltage / frequency | 220‑240V / 50Hz or 110‑120V / 60Hz |
| Speed | 2,850 – 3,450 rpm |
| Inlet / outlet size | 1" × 1" or 1.25" × 1" (25mm or 32mm) |
| Maximum operating pressure | 4 – 5 bar (60 – 75 psi) |
| Liquid temperature | 0 – 40°C |
| Enclosure protection | IP44 (standard) , IP54 (optional) |
| Thermal protection | Built-in (auto-reset or manual) |
| Included accessories | Pressure switch, small pressure tank (2–5 L), pressure gauge, priming plug |
| Type | Description | Best Use |
|---|---|---|
| Standard jet pump (single-stage) | Impeller + built-in ejector; compact and affordable | Garden watering, small house supply (1 bathroom) |
| Two-stage jet pump | Two impellers in series; higher pressure for taller houses or larger properties | 2–3 bathrooms, sprinkler systems |
| Convertible jet pump | Ejector can be mounted at the pump (shallow well) or in the well (deep well up to 20 m) | Dual‑purpose for future deeper wells |
For most garden and small home applications, the standard single-stage jet pump is sufficient.
| Component | Standard Material | Upgrade Option |
|---|---|---|
| Pump casing (volute) | Cast iron with epoxy coating | Stainless steel 304 |
| Impeller | Brass | Stainless steel, engineering plastic (for mild water) |
| Ejector / diffuser | Brass or engineered plastic | Stainless steel |
| Motor fan cover | Aluminium or steel | Stainless steel |
| Shaft | Stainless steel (AISI 304) | AISI 316 (for aggressive water) |
| Mechanical seal | Carbon / Ceramic / NBR | Silicon carbide / Viton |
| Fasteners | Zinc-plated steel | Stainless steel |
Cast iron pumps are durable and have good heat dissipation. For portable or corrosive water applications (salt, high chlorine), choose the stainless steel version.
| Suction Lift (meters) | Priming Time (approx.) | Flow Reduction |
|---|---|---|
| 2 m | 20–30 seconds | Minimal |
| 5 m | 40–60 seconds | ~5% |
| 8 m (maximum) | 90–120 seconds | ~15% |
The pump must be placed as close as possible to the water source to minimise suction pipe length.
Suction pipe diameter must be at least the pump inlet size – larger pipe reduces friction and improves priming.
All suction joints must be absolutely airtight – a tiny air leak will prevent priming.
The garden jet pump comes factory-fitted with a pressure switch and a small diaphragm tank (2–5 litres). The switch is pre-set to cut in at 1.5 bar (22 psi) and cut out at 3 bar (43 psi) – adjustable.
How it works:
When a tap is opened, system pressure drops; the switch starts the pump.
Pump runs, supplying water until the tap closes and pressure reaches cut-out setting.
The pump stops and rests until pressure drops again.
The small tank prevents short cycling and absorbs water hammer.
Adjustable pressure range: 1.0 – 3.5 bar (higher on request). For systems with more than 3–4 fixtures, add an external pressure tank.
Location: Place the pump on a solid, level, dry surface, protected from rain and direct sun. Allow air circulation around the motor.
Piping: Use rigid PVC or metal pipe for suction line. Keep suction pipe short (prefer <10 m), with as few elbows and fittings as possible. Slope suction pipe slightly upward to the pump.
Foot valve (optional but recommended): Install a foot valve at the bottom of the suction pipe in the well or tank to keep the line filled when the pump stops.
Priming: Remove the priming plug, fill the pump casing and suction pipe with water until full, then replace the plug. The pump will prime automatically on start-up if suction pipe is filled.
Electrical: Connect to a dedicated circuit with a residual current device (RCD). Follow local electrical codes. Ensure motor rotation direction is correct (for three-phase models – check label).
Pressure tank: The supplied small tank is adequate for light use. For heavy use, add a larger external tank.
Self-priming – No foot valve required (though recommended). Priming is automatic after initial fill.
Quiet operation – Specially designed hydraulic and motor reduce noise for garden and home use.
Built-in thermal protection – Motor automatically shuts off if overheated (e.g., dry run). Auto-reset or manual reset depending on model.
Corrosion-resistant – Cast iron with epoxy coating or full stainless steel for long life.
Easy maintenance – Simple seal and impeller replacement; strainer on suction prevents debris entry.
Pressure gauge – Allows quick check of system performance.
Dry run protection (premium models) – Electronic sensor stops pump if water supply fails.
| Application | Description |
|---|---|
| Shallow well water supply | Draw water from wells up to 8 m deep for home use |
| Rainwater harvesting | Pump rainwater from storage tanks to garden hose or house |
| Garden irrigation | Water lawns, flower beds, vegetable gardens via sprinklers or drip lines |
| Pressure boosting | Increase low mains water pressure to serve more fixtures |
| Car washing | Provide pressurised water for hose and washer |
| Small farm / livestock | Water troughs, small-scale spray irrigation |
Easy to install and use – Clear instructions; priming only once; automatic pressure control
Reliable self-priming – Proven ejector design lifts water up to 8 m, clears air locks
Energy-efficient motor – Copper windings, low noise, high starting torque
Corrosion-resistant – Epoxy coating or stainless steel ensures years of service even with aggressive well water
Safety features – Thermal overload, IP44/IP54 motor, optional dry-run protection
Compact design – Small footprint suits garden, basement, or well house
Value package – Includes pressure switch, pressure tank, gauge – ready to install
Global voltage options – 110V/60Hz for North America; 230V/50Hz for Europe, Asia, Africa
2-year warranty – Backed by responsive customer service
| Task | Frequency | Instructions |
|---|---|---|
| Clean inlet strainer | Every 3 months | Remove debris from suction strainer (foot valve) |
| Check pressure tank air charge | Every 6 months | With pump off, depressurise system; check air pressure (pre-charge 1.0–1.5 bar) |
| Inspect mechanical seal | Annually or when leaking | Replace seal kit if water drips from shaft |
| Winterization (freezing climates) | Before freeze | Drain pump and piping completely; store indoors or heat-trace |
| Motor bearings | When noisy | Bearings are sealed – replace motor if noisy |
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump runs but no water | Loss of prime, air leak, empty well | Re-prime; check suction joints; install foot valve; wait for well recovery |
| Pump cycles on/off rapidly | Leak in system, pressure tank waterlogged | Repair leaks; re‑pressurise tank air; replace tank if diaphragm failed |
| Low pressure | Clogged impeller, low voltage, air in line | Clean impeller; check voltage; bleed air |
| Motor hums but won't start | Stuck impeller, bad capacitor (single-phase) | Turn off power; clear debris from impeller; replace capacitor |
| Noisy operation | Cavitation (suction restriction), loose parts | Increase suction pipe size; check for blockage; tighten bolts |
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit | 1 set |
| Impeller (complete) | 1 |
| Diffuser / ejector | 1 set |
| Pressure switch | 1 |
| Small pressure tank (2–5 L) | 1 |
| Foot valve (1″ or 1.25″) | 1 (if not already installed) |
For detailed selection of the correct garden jet pump for your well depth, water demand, and garden size – including suction lift calculation, pipe sizing, and pressure switch setting – please contact our engineering team.
Email: info@hyrig.com
Our engineers support home and garden water supply projects worldwide with reliable, self‑priming jet pumps – from shallow well supply to rain barrel irrigation.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.