Our API 610 depentanizer reboiler pumps are available in BB2, OH, and VS designs, specifically engineered for circulating high‑temperature C6‑C9 aromatic bottoms from depentanizer columns through reboiler heat exchangers and to downstream processing units in refineries and petrochemical plants. BB2 pumps with radially split between‑bearings construction are the preferred choice for reliable aromatic reboiler duty, delivering stable high‑flow circulation with excellent rotor rigidity and thermal expansion management. OH pumps serve startup and trim services, while VS pumps handle low‑NPSH suction. Built with chrome‑moly, stainless, and fouling‑resistant alloys. Fully API 610/ISO 13709 compliant for long‑life, high‑temperature service.

Conatct For Details
DetailReview(0)Additional

Our API 610 depentanizer reboiler pumps are heavy‑duty centrifugal pumps engineered specifically for circulating high‑temperature C6‑C9 aromatic bottoms from the bottom of depentanizer columns through reboiler heat exchangers and back to the column. In refinery catalytic reforming and aromatics production units, the depentanizer column separates pentane (C5) and lighter components from heavier C6‑C9 aromatic hydrocarbons – including benzene, toluene, ethylbenzene, and xylenes (BTEX) – which are valuable feedstocks for the petrochemical industry. The bottom stream consists of C6‑C9 aromatics that must be continuously circulated through a reboiler to supply heat for the distillation process. This fluid is characterized by elevated temperatures (typically 150‑240°C), moderate viscosity, fouling tendencies (gum formation, polymerisation), and potential corrosivity from sulfur compounds. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for reliable, continuous operation under severe conditions. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – though the BB2 type (radially split, single‑stage or two‑stage) is the industry standard for main C6‑C9 aromatic reboiler circulation duty.

API 610 Classifications for Depentanizer Reboiler Duties

  • BB2 – Between Bearings Pumps (Preferred for Main Reboiler Circulation)
    For the main C6‑C9 aromatic reboiler circulation pump, the BB2 subtype (radially split, single‑stage or two‑stage, between‑bearings) is the overwhelmingly preferred configuration. The radially split casing is ideal for high‑temperature aromatic service, allowing the casing to expand evenly with temperature without distorting internal clearances – critical when handling streams with significant temperature differentials. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. Single‑stage BB2 pumps handle high flows (up to 2,500 m³/h) at moderate heads, while two‑stage variants cover higher head requirements. The robust bearing span and heavy‑duty shaft ensure long life even with fouling‑prone aromatic streams.

  • OH – Overhung Pumps
    In aromatic reboiler systems, OH pumps are typically employed for startup circulation, booster duties, or trim cooler services where temperatures and flows are lower. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for auxiliary roles. Centreline mounting ensures thermal expansion does not misalign the pump and driver.

  • VS – Vertically Suspended Pumps
    VS pumps are used on the suction side of reboiler systems or for handling bottoms with very low NPSH. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the first‑stage impeller in the column bottom sump, providing excellent NPSH performance. They are also used in closed‑loop systems where floor space is limited.

Key Performance & Design Features (BB2 Focus)

  • Temperature Capability – Engineered for C6‑C9 aromatic temperatures up to 240°C (464°F), with appropriate material selection and thermal expansion allowances.

  • Flow & Head – Capacities from 50 m³/h to over 2,500 m³/h; heads typically from 50 to 200 metres, matching reboiler exchanger pressure drop.

  • Casing Design – Radially split casing with top‑centreline or bottom‑centreline support to accommodate thermal expansion without distortion. Heavy‑wall construction for pressure integrity at elevated temperatures.

  • Materials – Wetted parts in chrome‑moly steels (ASTM A217 WC6/WC9), 12% chrome stainless steels, duplex stainless, or high‑alloy materials for corrosion resistance to sulfur compounds and naphthenic acids. Full hard facing on wear rings and impeller shrouds to resist fouling and erosion.

  • Fouling Resistance – Impeller and casing designs that minimise stagnant areas and gum/polymer deposition; optional steam tracing or jacketing to maintain fluidity and prevent polymerisation.

  • Sealing – API 682 mechanical seals (single, dual, or tandem) with high‑temperature flush plans – typically Plan 32 (clean injected flush), Plan 62 (steam quench), or Plan 53 (pressurised dual seal) – to prevent coke/gum formation and ensure seal face stability. Steam quench is strongly recommended for aromatic services to flush away any leakage and prevent gum build‑up.

  • Bearing & Lubrication – Heavy‑duty sleeve or tilting‑pad journal bearings and Kingsbury‑type thrust bearings with forced oil lubrication; bearing temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers with large clearances to handle thermal expansion and minor fouling; open or semi‑open designs for severe fouling services; all dynamically balanced per API 610.

  • Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate significant temperature gradients.

Typical Applications

  • C6‑C9 aromatic bottoms circulation in depentanizer columns

  • Reboiler circulation in refinery aromatics production units

  • Aromatic bottoms transfer to storage or downstream extraction units

  • Reboiler service in catalytic reforming unit depentanizers

  • Any fractionator handling C6‑C9 aromatic fractions requiring forced‑circulation reboilers

Industries Served

  • Oil refineries (catalytic reforming, aromatics production)

  • Petrochemicals (BTEX production)

  • Gas processing (condensate fractionation)

Why Choose Our Depentanizer Reboiler Pumps?

With deep expertise in high‑temperature hydrocarbon pumping and full API 610 compliance, we design and manufacture BB2 aromatic reboiler pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, fouling‑resistant impeller designs, and sealing arrangements tailored to your specific C6‑C9 aromatic composition, temperature, and fouling characteristics. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding reboiler services.

Contact Us

For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:

info@hyrig.com

Trust our API 610 depentanizer reboiler pumps to keep your aromatics fractionation process running reliably and efficiently.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit