HYRIG can supply DIN 3352 gate valves. Because the standard defines multiple face-to-face series, stem configurations, and wedge types, an incomplete RFQ often leads to a valve that fits the flanges but not the piping gap, or a wedge that binds in steam service.
To receive a correctly machined valve, provide the following data in your RFQ:
| Data Field | Why It Is Needed |
|---|---|
| Standard | Confirms DIN 3352 / EN 1984 as the design basis. |
| DN | Nominal size, determines bore and flange OD. |
| PN | Pressure rating, determines body thickness and face-to-face series. |
| Face-to-Face Series | Specify DIN 3202 F4/F5/F7/F8; this is not implied by DN and PN. |
| Stem Configuration | Specify OS&Y (rising) or NRS (non-rising). |
| Wedge Type | Specify solid or flexible wedge based on temperature and cycling. |
| Material | Specify body, trim, and stem materials per the service. |
| Documentation | State if EN 10204 3.1 certificates and DIN 3230 test reports are required. |
| Dimension | Standard |
|---|---|
| Face-to-face (PN10/PN16/PN25) | DIN 3202 F4 / F5 |
| Face-to-face (PN40/PN63/PN100) | DIN 3202 F7 |
| Face-to-face (PN160) | DIN 3202 F8 |
| Flange drilling | DIN 2543–2545 / EN 1092-1 |
The most common RFQ error is specifying the DN and PN but omitting the face-to-face series. Two valves with the same DN100 PN16 rating can have different lengths if one is built to F4 and the other to F5. A valve that fits the flanges may not fit the piping gap.
The second common error is omitting the stem configuration. An OS&Y valve requires headroom equal to the stem travel; an NRS valve does not. If the RFQ does not state the stem configuration, the supplier may quote the wrong valve for the installation.
The third error is omitting the wedge type for high-temperature service. A solid wedge may bind in steam or cyclic service. For main steam, superheated steam, or rapid thermal cycling, specify a flexible wedge.
When ordering replacement DIN gate valves:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Gate valves are for isolation only; do not use for throttling.
Q: Why do I need to specify the F-series face-to-face?
Because DIN 3202 defines multiple lengths for the same DN and PN. A valve with the correct flanges may still not fit the piping gap if the wrong series is supplied.
Q: Why do I need to specify OS&Y or NRS?
OS&Y requires headroom for the rising stem; NRS does not. The two configurations are not interchangeable in the same installation.
Q: What is the most important field for steam service?
The wedge type. A solid wedge may bind after thermal cycling; a flexible wedge is generally preferred for main steam and superheated service.
Q: What is the typical lead time?
Standard lead time is 4–6 weeks depending on size, PN rating, material, and documentation.
To ensure the DIN gate valve matches your piping and service, provide the DN, PN, existing gap, stem configuration, wedge type, and material requirement. Our engineering team will verify the specification against DIN 3352.
For DIN 3352 gate valve RFQ support, contact HYRIG: info@hyrig.com