DIN 3352 Gate Valve RFQ Checklist | PN, F Series & Stem

2026-11-19 19:17

DIN 3352 Gate Valve RFQ Checklist

HYRIG can supply DIN 3352 gate valves. Because the standard defines multiple face-to-face series, stem configurations, and wedge types, an incomplete RFQ often leads to a valve that fits the flanges but not the piping gap, or a wedge that binds in steam service.

Key Facts

  • Standard: Specify DIN 3352 / BS EN 1984, not just "DIN gate valve".
  • Face-to-face: Specify DIN 3202 F4, F5, F7, or F8. DN and PN alone are not sufficient.
  • Stem: Specify OS&Y (rising stem) or NRS (non-rising stem).
  • Wedge: Specify solid wedge or flexible wedge.

Key Specifications

To receive a correctly machined valve, provide the following data in your RFQ:

Data FieldWhy It Is Needed
StandardConfirms DIN 3352 / EN 1984 as the design basis.
DNNominal size, determines bore and flange OD.
PNPressure rating, determines body thickness and face-to-face series.
Face-to-Face SeriesSpecify DIN 3202 F4/F5/F7/F8; this is not implied by DN and PN.
Stem ConfigurationSpecify OS&Y (rising) or NRS (non-rising).
Wedge TypeSpecify solid or flexible wedge based on temperature and cycling.
MaterialSpecify body, trim, and stem materials per the service.
DocumentationState if EN 10204 3.1 certificates and DIN 3230 test reports are required.

Dimensions

DimensionStandard
Face-to-face (PN10/PN16/PN25)DIN 3202 F4 / F5
Face-to-face (PN40/PN63/PN100)DIN 3202 F7
Face-to-face (PN160)DIN 3202 F8
Flange drillingDIN 2543–2545 / EN 1092-1

Structure and Working Principle

The most common RFQ error is specifying the DN and PN but omitting the face-to-face series. Two valves with the same DN100 PN16 rating can have different lengths if one is built to F4 and the other to F5. A valve that fits the flanges may not fit the piping gap.

The second common error is omitting the stem configuration. An OS&Y valve requires headroom equal to the stem travel; an NRS valve does not. If the RFQ does not state the stem configuration, the supplier may quote the wrong valve for the installation.

The third error is omitting the wedge type for high-temperature service. A solid wedge may bind in steam or cyclic service. For main steam, superheated steam, or rapid thermal cycling, specify a flexible wedge.

Cross-Reference and Replacement

When ordering replacement DIN gate valves:

  1. Measure the existing gap: Record the face-to-face length and match it to the DIN 3202 series.
  2. Check the stem: Confirm whether the existing valve is OS&Y or NRS, and measure the headroom.
  3. Check the wedge: For high-temperature service, confirm whether a solid or flexible wedge was originally installed.
  4. Verify documentation: For classified lines, specify EN 10204 3.1 certificates and DIN 3230 test reports.

Applications

  • New plant construction: Matching the line class and face-to-face series exactly.
  • Maintenance and replacement: Replacing a stuck or leaking valve without modifying the piping.
  • Steam isolation: Specifying flexible wedge and correct PN rating for high-temperature service.
  • Buried lines: Specifying NRS stem for installations without headroom.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. Gate valves are for isolation only; do not use for throttling.

Frequently Asked Questions

Q: Why do I need to specify the F-series face-to-face?

Because DIN 3202 defines multiple lengths for the same DN and PN. A valve with the correct flanges may still not fit the piping gap if the wrong series is supplied.

Q: Why do I need to specify OS&Y or NRS?

OS&Y requires headroom for the rising stem; NRS does not. The two configurations are not interchangeable in the same installation.

Q: What is the most important field for steam service?

The wedge type. A solid wedge may bind after thermal cycling; a flexible wedge is generally preferred for main steam and superheated service.

Q: What is the typical lead time?

Standard lead time is 4–6 weeks depending on size, PN rating, material, and documentation.

Selection Support

To ensure the DIN gate valve matches your piping and service, provide the DN, PN, existing gap, stem configuration, wedge type, and material requirement. Our engineering team will verify the specification against DIN 3352.

Contact

For DIN 3352 gate valve RFQ support, contact HYRIG: info@hyrig.com