| Model | Nominal Size | Max Flow (L/min) | Max Pressure | Mounting Types |
|---|---|---|---|---|
| DR10 | DN10 | 80 | 31.5 MPa | Plate / Thread / Cartridge |
| DR20 | DN20 | 200 | 31.5 MPa | Plate / Thread / Cartridge |
| DR30 | DN30 | 300 | 31.5 MPa | Plate / Thread / Cartridge |
Data source: Technical data table.
Text-based mounting parameters for the DR30 series:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-05 to 08 (varies by size) |
| Port Connections | A, B, Y (O-ring sizes vary) |
| Weight | 2.6 kg to 9.8 kg |
The DR30 is a pilot-operated reducing valve. The main spool is normally open. The outlet pressure (A) acts on the pilot poppet via a control line. When the outlet pressure exceeds the spring setting, the pilot poppet opens, creating a pressure drop that throttles the main spool to maintain constant outlet pressure. DR20 and DR30 include a safety relief function to protect the reduced pressure side from overpressure.
`DR` + `Size` + `Mounting` + `30` + `Y` + `Pressure Range` + `M`.
Used in machine tools, metallurgy, and heavy machinery for pressure reduction in large flow circuits.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help choosing the mounting type or pressure range? Contact our engineers with your system specifications.
Q: What is the difference between DR10, DR20, and DR30?
A: They are different nominal sizes handling different maximum flows (80, 200, and 300 L/min respectively).
Q: Does the DR30 have a built-in relief valve?
A: Yes, DR20 and DR30 include an overload protection function on the secondary side.
Q: Can I use a DR30 valve for reverse flow?
A: Only if you order the version with an integral check valve (subplate type).
For DR30 series pilot-operated pressure reducing valve selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.