DZ30 Series Sequence Valves | Pressure-Controlled Actuation

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
HYRIG can supply the DZ30 series sequence valve range and their spare parts. These valves are designed to control the sequential operation of two or more actuators. The second actuator starts when the system pressure reaches the set value. Available in DN10, DN20, and DN30.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Valve Type: Sequence Valve (Pilot-operated)
  • Nominal Sizes: DN10, DN20, DN30
  • Max Working Pressure: 31.5 MPa
  • Max Flow Rate: 150 to 450 L/min
  • Pressure Setting: 0.3 to 21 MPa
  • Control Oil Types: Internal/External supply, Internal/External drain

DZ30 Series Specifications & Model Comparison

ModelNominal SizeMax Flow (L/min)Max PressureControl Oil Options
DZ10DN1015031.5 MPaInternal / External
DZ20DN2030031.5 MPaInternal / External
DZ30DN3045031.5 MPaInternal / External

Data source: Technical data table.

Dimensions

Text-based mounting parameters for the DZ30 series:

ParameterSpecification
Mounting TypeSubplate
Port ConnectionsA, B, X, Y (O-ring sizes vary)
Weight3.6 to 8.2 kg

Structure / Working Principle

The DZ30 is a normally closed valve. When the inlet pressure at port A exceeds the spring setting, the main spool opens, allowing flow to port B. This is used to sequence the operation of a second actuator after the first one has reached its required pressure. Different control oil configurations (Internal/External) allow flexibility in system design.

How to Order (Model Code)

`DZ` + `Size` + `30/210` + `Control Oil (No mark/X/Y/XY)` + `M (No check valve)`.

  • Control Oil: No mark (Internal/Internal), `X` (External/Internal), `Y` (Internal/External), `XY` (External/External).

Applications

Used in clamping circuits, punching machines, and any system requiring a specific sequence of actuator movements.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Need help choosing the correct control oil configuration? Contact our engineers with your circuit diagram.

Frequently Asked Questions

Q: How does a sequence valve differ from a relief valve?
A: A relief valve diverts flow to the tank to limit pressure. A sequence valve diverts flow to a secondary circuit to operate a second actuator.

Q: Can I adjust the sequence pressure?
A: Yes, the sequence pressure can be adjusted via the handle or knob.

Q: What is the function of the X and Y ports?
A: The X port allows external pilot oil supply, and the Y port allows external drain for the spring chamber.

Contact

For DZ30 series sequence valve selection and spare parts, contact HYRIG: info@hyrig.com