The EAP‑I series is a single‑stage, single‑suction, horizontal OH2 centerline‑mounted chemical process pump designed to API 610. Design pressure ≤2.5 MPa, temperature range -40℃ to +200℃. Flow 7.2‑3600 m³/h, head 5‑320 m. OH2 heavy‑duty structure with back pull‑out, API 682 seal compatibility, standard bearings. Complete model range from DN25 to DN250 (34 models listed). Materials: carbon steel, 304/316 stainless steel. Direct replacement for Sulzer PRE, Flowserve 3700, KSB RPH, Goulds 3700/3900. Ideal for conventional petrochemical processes, medium‑pressure boiler feed, cooling water, solvent circulation, and general industrial applications. Contact info@hyrig.com for catalog and quote.

Conatct For Details
DetailReview(0)Additional

Product Name: Single‑Stage Single‑Suction Horizontal Chemical Centrifugal Pump
Model: EAP‑I Series
Structure: OH2 (Centerline‑Mounted)
Design Standard: API 610 (10th/11th/12th editions), GB/T 5656
Positioning: Medium temperature & medium pressure – basic / general‑purpose model of EAP family

Performance Range

  • Design Pressure: ≤ 2.5 MPa (medium pressure)

  • Temperature Range: -40℃ ~ +200℃ (medium temperature)

  • Structure: Single‑stage, single‑suction, horizontal overhung, OH2 centerline‑mounted

  • Media: Clean liquids, oil products, water, solvents, neutral and weakly corrosive media

EAP‑I Series – Complete Model Selection Table (All Models)

ModelInlet DNFlow (m³/h)Head (m)Speed (rpm)PressureTemp (℃)StructureStandard
EAP‑I‑25‑160257.2~2885~1202900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑25‑200257.2~28810~1602900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑25‑250257.2~18015~2002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑40‑1604021.6~4325~1202900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑40‑2004021.6~43210~1602900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑40‑2504021.6~36015~2002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑40‑3154021.6~36020~2502900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑50‑1605036~6485~1202900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑50‑2005036~64810~1602900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑50‑2505036~57615~2002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑50‑3155036~57620~2502900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑50‑4005036~57625~3002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑80‑1608072~10085~1202900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑80‑2008072~100810~1602900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑80‑2508072~100815~2002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑80‑3158072~100820~2502900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑80‑4008072~100825~3002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑100‑160100108~14405~1202900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑100‑200100108~144010~1602900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑100‑250100108~144015~2002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑100‑315100108~144020~2502900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑100‑400100108~144025~3002900/1450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑150‑200150180~21608~1501450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑150‑250150180~216012~2001450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑150‑315150180~216018~2501450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑150‑400150180~216025~3001450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑150‑500150180~216030~3201450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑200‑250200288~28808~1501450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑200‑315200288~288012~2001450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑200‑400200288~288018~2501450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑200‑500200288~288025~3001450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑250‑315250360~360010~1601450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑250‑400250360~360015~2001450≤2.5MPa-40~200OH2API610 / GB/T5656
EAP‑I‑250‑500250360~360020~2501450≤2.5MPa-40~200OH2API610 / GB/T5656

Structural Features

  • Single‑stage, single‑suction, OH2 centerline‑mounted – minimal thermal deformation, ideal for medium temperature

  • Back pull‑out overhung design – maintenance without removing suction/discharge piping

  • API 682 seal compatibility – single mechanical seal for medium temperature & pressure

  • Standard bearing configuration – stable operation, low cost, high parts interchangeability

  • Material options – carbon steel, 304/316 stainless steel for neutral and weakly corrosive media

Typical Applications (Matching Medium Temperature & Medium Pressure)

  • Petrochemical – conventional process transfer, medium‑temperature crude oil / product oil transfer, solvent circulation

  • Coal Chemical – medium‑temperature coal‑water slurry, low‑pressure desulfurization systems, process water circulation

  • Energy & Power – medium‑pressure boiler feed water, industrial cooling water, heat exchange system circulation

  • Others – general industrial processes, water treatment, HVAC circulation, mildly corrosive media transfer

Direct Replacement for International Brands

EAP‑I series directly replaces equivalent API 610 OH2 medium pressure pumps from:

  • Sulzer PRE series (medium pressure variants)

  • Flowserve 3700 series (standard pressure)

  • KSB Etanorm API / RPH series

  • Goulds 3700 / 3900 series

Same mounting dimensions, same hydraulic performance – true drop‑in replacement.

Contact Us

For technical support, price inquiries, cross‑reference, or catalog request:

Email: info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit