Electric Fracturing Pump System | 3300V VFD Solution

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
HYRIG can supply the Electric Fracturing Pump System and its spare parts. The Electric Fracturing Pump System is a high-power electric drive solution designed for shale gas and coalbed methane fracking operations, available in 600V, 3300V, 6kV, and 10kV configurations to replace traditional diesel-driven pumps.
Conatct For Details
DetailReview(0)Additional

HYRIG can supply the Electric Fracturing Pump System and its spare parts. The Electric Fracturing Pump System is a high-power electric drive solution designed for shale gas and coalbed methane fracking operations, available in 600V, 3300V, 6kV, and 10kV configurations to replace traditional diesel-driven pumps.

Key Facts

  • Application: Shale gas and coalbed methane fracturing
  • Voltage Levels: 600V, 3300V, 6kV, 10kV
  • Power Range: 800HP to 8000HP (single unit)
  • Key Features: Stepless speed regulation, zero emissions, low noise
  • Energy Saving: Over 30% reduction in energy consumption vs diesel
  • System Components: VFD room, mobile substation, plunger pump motor

Key Specifications

System VoltageInverter ModelPump Power (HP)Transformer Capacity (kVA)Inverter Power (kW)Motor PhasesCooling Method
600VYX-L690-HP2800230021003 or 6 PhasesAir-cooled
3300VYX-M3K3-HP5500420041003 PhasesWater-cooled
6kVYX-H6K0-HP6000480045003 PhasesAir-cooled
10kVYX-H6K0-HP8000640060003 PhasesAir-cooled

Data source: Technical data table.

Dimensions

System dimensions depend on the selected power configuration and whether a mobile substation or VFD room is included. A standard 3300V system VFD room measures approximately 8700mm (W) x 2900mm (D) x 3000mm (H). For specific footprint and weight data, contact HYRIG with your pump specifications.

Structure / Working Principle

The system uses a multi-pulse rectifier and a three-level inverter topology to convert medium voltage power into adjustable frequency output for the plunger pump motor. It utilizes advanced vector control technology to provide large starting torque and fast torque response. The system features fiber-optic isolation between the control circuit and main circuit, ensuring strong anti-interference ability. The electric drive eliminates the gearbox and diesel engine, achieving direct drive and stepless speed regulation.

Cross-Reference & Replacement

When replacing a diesel-driven fracturing pump with an electric system, verify: 1. Power Requirement: Match the horsepower (HP) to the equivalent electric motor power (kW). 2. Available Grid Voltage: Choose 600V, 3300V, 6kV, or 10kV based on your site's power supply. 3. Cooling Method: Water-cooled for high-power 3300V systems, air-cooled for 6kV/10kV systems. 4. Footprint: Electric systems require significantly less space than diesel trucks.

Applications

The Electric Fracturing Pump System is suitable for large-scale artificial fracturing operations in shale gas fields. It provides higher flow control precision, lower noise, and zero emissions compared to diesel systems.

Disclaimer: This equipment is a heavy-duty industrial electrical device. Install and maintain it in strict accordance with local electrical safety regulations and the manufacturer's instructions; ensure proper grounding, insulation, and overload protection before energizing.

Spare Parts

HYRIG provides replacement parts for the Electric Fracturing Pump System, including VFD Motors, Medium Voltage VFDs, and Mobile Substations. Contact HYRIG for a complete parts list and technical support.

Frequently Asked Questions

Q: What is the maximum power of a single electric fracturing pump? A: Up to 8000HP depending on the voltage level and configuration. Q: Can this system work in remote areas without a power grid? A: It can be powered by gas turbines or diesel generators supplying the required voltage. Q: What is the lead time for a complete system? A: Contact HYRIG for current availability and customized project scheduling. Q: Is the system compatible with 6-phase motors? A: Yes, the 600V and 3300V systems support 3-phase or 6-phase motor options for redundancy.

Selection Support

Need help designing an electric fracturing solution for your field? Tell us your pump horsepower, required voltage, and site conditions, and HYRIG engineers will propose the best configuration. Explore related products: Medium Voltage VFD or view the Mobile Substation.

Contact

For Electric Fracturing Pump System selection and spare parts, contact HYRIG: info@hyrig.com