HYRIG can supply the FD16 counterbalance valve range and its spare parts. The FD16 is a pilot-operated check valve designed to control the speed of hydraulic actuators regardless of load. It prevents load runaway in case of pipe failure. Available in DN16 with thread, subplate, and SAE flange mounting.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Valve Type: Counterbalance Valve
  • Nominal Size: DN16
  • Max Working Pressure (Port B): 42 MPa
  • Max Pilot Pressure (Port X): 31.5 MPa
  • Max Flow Rate: 200 L/min
  • Pilot Ratio: 1:20 (Piston area to seat area)
  • Mounting Types: Threaded (KA), Subplate (PA), SAE Flange (FA/FB)

FD16 Specifications & Model Comparison

ModelNominal SizeMax Pressure (Port B)Max FlowPilot RatioMounting Options
FD16DN1642 MPa200 L/min1:20KA / PA / FA / FB
FD12 ValveDN1242 MPa80 L/min1:20KA / PA / FA / FB
FD25 ValveDN2542 MPa320 L/min1:20KA / PA / FA / FB

Data source: Technical data table.

Dimensions (Text-Based)

The FD16 is available in three mounting styles with different dimensions.

1. Threaded Connection (KA Type)

ParameterSpecification
Thread SizeM42x2 (Ports A, B, X)
Body Width70 mm
Body Height60 mm
MountingIn-line (Threaded)

2. Subplate Mounting (PA Type)

ParameterSpecification
Mounting InterfaceISO 4401 / Custom 4-bolt
Port ConnectionsA, B, X on subplate
Body Length122 mm
Body Width66.5 mm
WeightApprox. 9 kg

3. SAE Flange Mounting (FA/FB Type)

ParameterSpecification
Flange Size1/2" SAE
Port ConnectionsFlange ports A, B
Body Width50.8 mm
WeightApprox. 7 kg (Without secondary relief)

Structure / Working Principle

The FD16 counterbalance valve operates in two modes:

  1. Free Flow (A to B): When fluid flows from A to B, it opens the integral check valve, allowing unrestricted flow to the actuator.
  2. Load Holding (B to A): The main spool is held closed by the spring and the load pressure at port B. The valve only opens when the pilot pressure at port X (from the opposite side of the circuit) overcomes the spring force and the load pressure (at a 1:20 ratio). This prevents the load from dropping if a hose bursts.

Secondary Relief Valve (Type B):
If your system requires protection against pressure spikes, the FB type includes an integrated secondary pressure relief valve (set up to 40 MPa) to protect the actuator.

How to Order (Model Code)

The FD16 model code is built as follows: `FD16` + `Mounting` + `A/B` + `Series` + `Orifice` + `Options`.

  • Mounting: `KA` (Threaded), `PA` (Subplate), `FA` (SAE Flange without relief), `FB` (SAE Flange with relief).
  • A/B: `A` (Without secondary relief), `B` (With secondary relief, for FA/FB only).
  • Orifice: `B00` (No orifice), `B30` (0.3 mm), `B40` (0.4 mm).

Example: `FD16FB12/B40` = DN16 SAE flange mounting, with secondary relief valve, 12 series, 0.4 mm orifice.

Cross-Reference & Replacement

Replacing an old counterbalance valve? Check:

  1. Pilot Ratio: Ensure the 1:20 ratio matches your cylinder area ratio.
  2. Mounting Type: Verify if you need threaded, subplate, or SAE flange connections.
  3. Secondary Relief: Determine if you need the integrated relief valve (FB type) based on your safety requirements.

Applications

Used in applications with suspended loads, such as:

  • Cranes and winches: To hold loads securely and prevent dropping.
  • Hydraulic presses: To control the descent speed of the ram.
  • Boom cylinders: To prevent cylinder retraction in case of pressure loss.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Not sure whether you need the KA, PA, or FA mounting type, or if you require the secondary relief valve? Explore related models: FD12 Valve or contact our engineers with your system requirements.

Frequently Asked Questions

Q: What is the maximum pilot pressure for the FD16?
A: The maximum pilot pressure at port X is 31.5 MPa.

Q: What does the pilot ratio 1:20 mean?
A: It means that the pilot pressure required to open the valve is 1/20th of the load pressure at port B.

Q: What is the difference between FA and FB types?
A: FA is the SAE flange type without a secondary relief valve. FB includes a built-in secondary pressure relief valve.

Q: Do you provide replacement seal kits for the FD16?
A: Yes, we supply drop-in replacement seal kits, including O-rings and backup rings.

Contact

For FD16 counterbalance valve selection and spare parts, contact HYRIG: info@hyrig.com