Gardner Denver PZ‑8 / PZ‑9 FLUID END – OEM Part No. 205PZL029D (Fluid Cylinder, Integral Suction/Discharge)

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
OEM Gardner Denver PZ-8/PZ-9 FLUID END: fluid cylinder 205PZL029D (single unit, integral suction/discharge). Fully interchangeable between PZ-8 and PZ-9. 7500psi, functions as hydraulic cylinder / hydraulic box. Related parts: valve cover 2011860, seal 2011699, locking device 2011857, liner 1191-40-P (4"), liner gasket 25AT37. Email info@hyrig.com
Conatct For Details
DetailReview(0)Additional

The 205PZL029D is an original equipment manufacturer (OEM) FLUID END – a single, integral fluid cylinder that combines both suction and discharge functions in one housing. It is produced for the Gardner Denver PZ‑8 and PZ‑9 triplex mud pumps (both models share the same fluid end, fully interchangeable). Rated at 7,500 psi (51.7 MPa) , this FLUID END is designed for high‑pressure drilling, deep wells (5,000–8,000 meters), and demanding land/offshore operations. It functions as both a hydraulic cylinder and a complete hydraulic box – three units are required per pump (one per cylinder, same part number).

Key Specifications

ParameterGardner Denver PZ‑8 / PZ‑9 FLUID END
OEM Part No. (single fluid cylinder – integral)205PZL029D (suction and discharge in one housing)
Pump ModelsGardner Denver PZ‑8, Gardner Denver PZ‑9 (fully interchangeable)
Pump ConfigurationTriplex pump – requires 3 x 205PZL029D per pump
Working Pressure7,500 psi (51.7 MPa)
Hydrostatic Test Pressure11,250 psi (77.6 MPa) – 1.5× rated
Max Liner ID4″ (101.6 mm) – liner example 1191-40-P
Valve TypeAccepts standard PZ‑8/PZ‑9 valve assemblies (not specified)
MaterialHigh‑strength alloy forged steel, quenched and tempered
SealingAPI 7,500 psi rated flanges, metal‑to‑metal seals
ConfigurationIntegral suction/discharge – no separate modules
InterchangeabilityFully interchangeable between PZ‑8 and PZ‑9 pumps
Operating Temperature-20°C to +130°C

Related Wear Parts & Consumables (OEM for PZ‑8/PZ‑9)

ComponentOEM Part No.Description
Valve Cover2011860High‑pressure valve cover for fluid end
Valve Cover Seal / O‑Ring2011699Seal ring for valve cover
Valve Cover Locking Device2011857Locking mechanism / retainer for valve cover
Liner (example 4″ / 101.6 mm)1191-40-PCylinder liner, 4″ ID (other sizes available)
Liner Gasket / Seal25AT37Gasket for liner installation

Structural & Design Advantages – An Integral 7500psi FLUID END

  • Integral suction / discharge design – The 205PZL029D combines both suction and discharge ports in a single, compact forged body, eliminating separate modules and reducing potential leak paths.

  • Straight flow channels – Short, smooth passages minimize erosion and pressure loss even at high circulation rates.

  • Thick‑wall forged construction – Designed to withstand 7,500 psi cyclic service with high safety margin.

  • Metal‑to‑metal rigid seals – Valve cover (2011860) with seal (2011699) and locking device (2011857) ensures zero leakage under pressure.

  • Modular pump assembly – Three identical fluid cylinders per pump, simplifying spare parts inventory.

Why Choose This Gardner Denver PZ‑8/PZ‑9 FLUID END?

  1. OEM fit for two pump models – Exactly matches PZ‑8 and PZ‑9, eliminating compatibility concerns. Single part number for both.

  2. Forged 7,500 psi durability – High‑strength alloy forging resists fatigue, erosion, and corrosion in demanding high‑pressure environments.

  3. Integral design – Fewer components than modular designs, reducing installation time and maintenance complexity.

  4. Complete OEM wear parts availability – Valve cover (2011860), seal (2011699), locking device (2011857), liners (1191-40-P), and gasket (25AT37) are readily available.

Applications – The High‑Pressure FLUID END for PZ‑8/PZ‑9 Pumps

  • Gardner Denver PZ‑8 and PZ‑9 mud pumps – deep wells (5,000–8,000 meters), high‑pressure drilling (≤7,500 psi), land and offshore rigs.

  • Suitable drilling environments – High‑pressure, high‑sand drilling fluids, high‑temperature conditions.

  • Compatible components – Pairs with valve assemblies (consult OEM), liners (e.g., 1191-40-P for 4″), valve cover kit (2011860/2011699/2011857), and liner gasket 25AT37.

Procurement & Replacement Notes

  • Order 205PZL029D for a single fluid cylinder – three units required per complete pump (one per cylinder).

  • Order 2011860 (valve cover), 2011699 (seal), and 2011857 (locking device) for valve cover replacement.

  • Order 1191-40-P for 4″ liner (specify other sizes if needed).

  • Order 25AT37 for liner sealing gasket.

  • Interchangeability – Fully interchangeable between PZ‑8 and PZ‑9. Not interchangeable with other GD pump models (e.g., PZ‑7, PZ‑10) without verification.

  • Maintenance tips – Inspect valve cover seals (2011699) regularly. Replace locking devices if damaged. Perform magnetic particle inspection every 500 operating hours. Re‑tighten all fasteners to specified torque quarterly.

Contact for Genuine Gardner Denver PZ‑8/PZ‑9 FLUID END & Wear Parts

For pricing, technical datasheets, or ready stock of the Gardner Denver PZ‑8/PZ‑9 FLUID END (205PZL029D) and related wear parts (valve cover, seal, locking device, liners, gasket), please email:

info@hyrig.com

OEM quality, global shipping. Complete FLUID END solutions for Gardner Denver PZ series, WIRTH TPK, IDECO T, OILWELL, National, BOMCO, LS, Honghua, EMSCO, and other pump models available.