HYRIG can supply the HED1 and HED10 pressure switch range and their spare parts. These plunger-type pressure relays convert hydraulic pressure signals into electrical signals to control solenoid valves, clutches, or motors. Available with or without a drain port, handling pressures up to 50 MPa.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Valve Type: Plunger Pressure Switch (Relay)
  • Max Working Pressure: 50 MPa (depending on model)
  • Pressure Setting Range: 5 MPa to 50 MPa
  • Drain Port: HED1 (With drain port), HED10 (Without drain port)
  • Electrical Connection: Cable gland
  • Switching Frequency: Up to 300 cycles/min (HED1)

HED1/HED10 Specifications & Model Comparison

ModelMax Pressure SettingDrain PortSwitching FrequencyElectrical Options
HED150 MPaYesUp to 300 cycles/minLED (24V, 110V, 220V)
HED1035 MPaNoUp to 50 cycles/minLED (24V, 110V, 220V)

Data source: Technical data table.

Dimensions

Text-based mounting parameters for the HED1/HED10:

ParameterSpecification
Body Width44 mm
Body Height178 mm
Thread ConnectionM14x1.5
WeightApprox. 1.2 kg

Structure / Working Principle

When the system pressure reaches the set spring force, the plunger moves and actuates the microswitch, sending an electrical signal. The switching pressure can be adjusted by changing the internal spring compression.

  • HED1: Requires a drain line (port T) to prevent backpressure from affecting the setting.
  • HED10: No drain line required, used in simpler circuits where backpressure is not an issue.

How to Order (Model Code)

`HED1/HED10` + `A` + `40` + `Pressure Range (100/350/500)` + `LED Option (L24/L110/L220)`.

  • Pressure Range: `100` (10 MPa), `350` (35 MPa), `500` (50 MPa).

Applications

Used for safety interlocks, sequence control, and system pressure monitoring in hydraulic power units and machine tools.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Need help choosing the pressure range or LED voltage? Contact our engineers with your system specifications.

Frequently Asked Questions

Q: What is the difference between HED1 and HED10?
A: HED1 has a drain port to prevent backpressure from affecting the pressure setting, while HED10 does not.

Q: What is the electrical contact rating?
A: The contacts are rated for 460V AC at 15A, or 40V DC at 1.0A.

Q: Can I adjust the switching pressure?
A: Yes, the switching pressure can be adjusted by changing the internal spring compression.

Contact

For HED1 and HED10 pressure switch selection and spare parts, contact HYRIG: info@hyrig.com