Our API 610 hot water circulation pumps are available in BB2, OH, and VS designs, specifically engineered for circulating high‑temperature boiler water (furnace water) in industrial boiler systems, power generation plants, heat recovery units, and process heating applications. BB2 pumps with radially split between‑bearings construction are the preferred choice for reliable high‑temperature circulation duty, delivering stable high‑flow performance with excellent rotor rigidity and thermal expansion management. OH pumps serve smaller loops and auxiliary services, while VS pumps handle low‑NPSH suction. Built with chrome‑moly, stainless, and high‑temperature alloys. Fully API 610/ISO 13709 compliant for long‑life, high‑temperature boiler water circulation service.

Conatct For Details
DetailReview(0)Additional

Our API 610 hot water circulation pumps are heavy‑duty centrifugal pumps engineered specifically for circulating high‑temperature boiler water (furnace water) in industrial boiler systems, power generation plants, heat recovery steam generators (HRSGs), and process heating applications. Boiler water – also referred to as furnace water or circulating water – is the high‑temperature, high‑pressure water that circulates through boiler tubes and heat exchangers, absorbing heat from combustion gases and converting it to steam. This fluid is typically operated at temperatures ranging from 150°C to 320°C (302°F to 608°F) and pressures up to 200 barg, requiring pumps with exceptional thermal stability, reliable sealing, and robust construction for continuous operation. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for reliable, long‑life performance under severe thermal cycling conditions. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – though the BB2 type (radially split, single‑stage or two‑stage) is the preferred choice for main high‑temperature boiler water circulation duties due to its superior thermal expansion management and rotor stability.

API 610 Classifications for Hot Water Circulation Duties

  • BB2 – Between Bearings Pumps (Preferred for Main High‑Temperature Circulation)
    For main boiler water circulation in high‑temperature heating systems, the BB2 subtype (radially split, single‑stage or two‑stage, between‑bearings) is the preferred configuration. The radially split casing is ideal for high‑temperature water service, allowing the casing to expand evenly with temperature without distorting internal clearances – critical when handling significant temperature differentials. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. Single‑stage BB2 pumps handle high flows (up to 3,000 m³/h) at moderate heads, while two‑stage variants cover higher head requirements. Centreline or foot mounting options are available to accommodate thermal expansion.

  • OH – Overhung Pumps
    In boiler water circulation systems, OH pumps are typically employed for smaller heating loops, booster duties, or auxiliary circulation where temperatures and flows are moderate. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for secondary loops and auxiliary services. Centreline mounting ensures thermal expansion does not misalign the pump and driver.

  • VS – Vertically Suspended Pumps
    VS pumps are used in applications where boiler water is drawn from low‑NPSH storage tanks, sumps, or collection vessels. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the impeller below the liquid level, providing excellent NPSH performance and eliminating priming issues. Their vertical footprint saves valuable plot space.

Key Performance & Design Features (BB2 Focus)

  • Temperature Capability – Engineered for boiler water temperatures up to 320°C (608°F), with appropriate material selection and thermal expansion allowances.

  • Flow & Head – Capacities from 20 m³/h to over 3,000 m³/h; heads typically from 30 to 250 metres.

  • Pressure Rating – Designed for discharge pressures up to 200 barg, matching boiler system requirements.

  • Casing Design – Radially split casing with appropriate support (centreline or foot) to accommodate thermal expansion without distortion. Heavy‑wall construction for pressure integrity at elevated temperatures.

  • Materials – Wetted parts in chrome‑moly steels (ASTM A217 WC6/WC9), stainless steels (304L, 316L), duplex, or high‑temperature alloys to resist hot water corrosion, thermal fatigue, and scaling. Internal coatings optional for enhanced corrosion protection.

  • Sealing – API 682 mechanical seals (single, dual, or tandem) with appropriate flush and cooling plans – typically Plan 23 (cooled seal chamber), Plan 32 (clean flush), or Plan 53 (pressurised dual seal) – to maintain seal integrity at elevated temperatures.

  • Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate significant temperature gradients during startup and operation.

  • Bearing & Lubrication – Heavy‑duty sleeve or rolling element bearings with forced oil, oil mist, or grease lubrication; bearing temperature and vibration monitoring for predictive maintenance.

  • Impeller Options – Closed impellers for efficient handling; special hydraulics to minimise cavitation and maintain efficiency at elevated temperatures.

  • Corrosion Protection – Internal coatings (epoxy or ceramic) for added corrosion resistance and to maintain water quality.

Typical Applications

  • Boiler water circulation in industrial water‑tube and fire‑tube boilers

  • Circulating water in heat recovery steam generators (HRSGs)

  • Forced circulation boiler systems in power generation plants

  • High‑temperature water loops in chemical and petrochemical processing

  • Waste heat recovery and cogeneration (CHP) systems

  • Process heating and district heating systems

Industries Served

  • Power generation (thermal and combined cycle plants)

  • Oil refineries and petrochemicals (process heating)

  • Chemical processing (jacketed vessel and reactor heating)

  • Pulp and paper (recovery boiler circulation)

  • Food and beverage processing

  • District heating and cogeneration facilities

Why Choose Our Hot Water Circulation Pumps?

With deep expertise in high‑temperature water handling and full API 610 compliance, we design and manufacture hot water circulation pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, and sealing arrangements tailored to your specific boiler water properties, temperature, and operating conditions. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding boiler water circulation services.

Contact Us

For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:

info@hyrig.com

Trust our API 610 hot water circulation pumps to keep your boiler systems running reliably and efficiently.