Our API 610 reformer injection water pumps are heavy‑duty centrifugal pumps engineered specifically for high‑temperature condensate injection into catalytic reforming units – critical for process temperature control, reactor quench, wash water applications, and ammonium salt fouling prevention. In catalytic reforming, condensate (or demineralized water) is injected at various points in the process to control reactor inlet temperatures, quench exothermic reactions, and wash ammonium chloride salts from reactor effluent air coolers and downstream equipment. The injection water is typically at elevated temperatures (up to 200°C) and moderate to high pressures (up to 100 barg), requiring pumps with exceptional thermal stability, corrosion resistance, and reliable performance under continuous or intermittent operation. Manufactured in strict compliance with the latest edition of API 610 (ISO 13709), these pumps are designed for maximum safety, reliability, and longevity in demanding refinery applications. The API 610 standard provides three primary configurations – OH (Overhung), BB (Between Bearings), and VS (Vertically Suspended) – with the BB2 type (radially split, single‑stage or two‑stage) often preferred for main injection duties due to its superior thermal expansion management and rotor stability.
API 610 Classifications for Reformer Injection Duties
BB2 – Between Bearings Pumps (Preferred for Main Injection)
For main high‑temperature condensate injection into catalytic reforming units, the BB2 subtype (radially split, single‑stage or two‑stage, between‑bearings) is the preferred configuration. The radially split casing is ideal for high‑temperature water service, allowing the casing to expand evenly with temperature without distorting internal clearances. The between‑bearings arrangement provides exceptional rotor rigidity, minimising shaft deflection and vibration. Single‑stage BB2 pumps handle moderate flows (up to 1,000 m³/h) at heads up to 300 metres, while two‑stage variants cover higher pressure requirements. Centreline support accommodates thermal expansion.
OH – Overhung Pumps
In reformer injection systems, OH pumps are typically employed for smaller injection duties, booster services, or auxiliary wash water applications where temperatures and flows are moderate. The OH2 (horizontal, centreline‑mounted) and OH3 (vertical inline) subtypes provide compact, cost‑effective solutions for auxiliary injection points. Centreline mounting ensures thermal expansion does not misalign the pump and driver.
VS – Vertically Suspended Pumps
VS pumps are used for low‑NPSH suction from condensate storage tanks or collection sumps. VS1 (vertical turbine) and VS6 (vertical can/barrel) types submerge the impeller below the liquid level, eliminating cavitation and priming problems. Their vertical footprint saves valuable plot space.
Key Performance & Design Features (BB2 Focus)
Temperature Capability – Engineered for condensate temperatures up to 200°C (392°F), with appropriate material selection and thermal expansion allowances.
Flow & Head – Capacities from 20 m³/h to over 1,000 m³/h; heads typically from 50 to 300 metres, matching injection system requirements.
Pressure Rating – Designed for discharge pressures up to 100 barg, matching reformer operating conditions.
Casing Design – Radially split casing with centreline support to accommodate thermal expansion without distortion. Heavy‑wall construction for pressure integrity at elevated temperatures.
Materials – Wetted parts in stainless steels (304L, 316L, duplex) and corrosion‑resistant alloys to withstand hot condensate corrosion and maintain water quality. Internal coatings available for enhanced corrosion protection.
Sealing – API 682 mechanical seals (single, dual, or tandem) with appropriate flush and cooling plans – typically Plan 23 (cooled seal chamber) or Plan 32 (clean flush) – to maintain seal integrity at elevated temperatures.
Thermal Expansion – Adequate internal clearances, expansion joints, and flexible coupling designs to accommodate significant temperature gradients during startup and operation.
Bearing & Lubrication – Heavy‑duty sleeve or rolling element bearings with forced oil or oil mist lubrication; bearing temperature and vibration monitoring for predictive maintenance.
Impeller Options – Closed impellers for efficient handling; special hydraulics to minimise cavitation and maintain efficiency at elevated temperatures.
NPSH Performance – Optimised first‑stage impeller design for low NPSH requirements where suction conditions are challenging.
Typical Applications
Condensate injection for reactor temperature control in catalytic reforming
Quench water injection in reformer reactor trains
Wash water injection upstream of reformer effluent air coolers (ammonium salt fouling prevention)
Process water injection for catalyst regeneration and maintenance
High‑temperature water transfer in refinery utility systems
Deaerated water injection for corrosion control in high‑pressure systems
Industries Served
Oil refineries (catalytic reforming, aromatics production)
Petrochemicals (process water injection)
Power generation (boiler feed and utility water)
Why Choose Our Reformer Injection Water Pumps?
With deep expertise in high‑temperature water handling and full API 610 compliance, we design and manufacture reformer injection water pumps that deliver unmatched reliability, safety, and efficiency. Every pump undergoes rigorous hydrostatic testing, performance curve verification, mechanical running tests, and comprehensive NDT inspections (radiographic, ultrasonic, dye penetrant) with complete documentation to meet the most stringent owner‑operator specifications. We offer customised hydraulic designs, material upgrades, and sealing arrangements tailored to your specific condensate properties, temperature, and operating conditions. Our engineering support includes API 684 rotor dynamics, thermal expansion analysis, and NPSH margin studies to ensure seamless, long‑term operation in the most demanding reformer injection services.
Contact Us
For technical datasheets, application engineering advice, or a project‑specific quotation, please contact us at:
info@hyrig.com
Trust our API 610 reformer injection water pumps to maintain precise temperature control and protect your reforming unit equipment.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.