HYRIG can supply the Z1S series hydraulic check valves. The Z1S6 is a size 6 direct-acting sandwich plate valve designed for vertical stacking. It allows free flow in one direction and provides leak-free metal-to-metal sealing in the reverse, rated up to 31.5 MPa.
Data source: Technical data table.
| Parameter | Z1S6 |
|---|---|
| Max Flow | 40 L/min |
| Opening Pressures | 0.05, 0.3, 0.5 MPa |
| Weight | 0.8 kg |
| Mounting Standard | DIN 24340 (CETOP 3) |
Typical Ordering Code Examples:
Z1S6-30/ : Size 6, standard configuration.Z1S6A-30/ : Size 6, variant A.The Z1S6 features a conical poppet and a return spring inside the housing. Forward fluid pressure pushes the poppet off the seat, allowing flow. Reverse pressure seats the poppet tightly against the body. The valve uses a metal-to-metal seal between the poppet and body, ensuring leak-free performance in the blocked direction.
Replacing a Z1S6? Verify the stacking interface and port layout. Confirm the opening pressure required for your circuit. Note that the Z1S6 is a direct-acting check valve. If your system requires pilot-operated opening for reverse flow, consider the Z2S6 Hydraulic Pilot Check Valve.
Used in hydraulic systems for directional control, pump isolation, and pressure holding where a compact sandwich plate design is required. Commonly found in machine tools and hydraulic power units.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
HYRIG can supply replacement O-ring kits for the Z1S6 stacking interface.
Need a larger flow capacity? Explore the Z1S10 Hydraulic Check Valve. You can also view all Hydraulic Check Valves.
1. What is the difference between Z1S6 and Z2S6?
Z1S6 is a direct-acting check valve (only opens under forward pressure). Z2S6 is a pilot-operated check valve, meaning reverse flow can be opened by applying pilot pressure.
2. What is the maximum flow for Z1S6?
The recommended max flow is 40 L/min.
3. Does it use an elastomeric or metal seal?
The Z1S6 uses a metal-to-metal seal between the poppet and the valve body for leak-free sealing.
For Z1S6 hydraulic check valve selection and spare parts, contact HYRIG: info@hyrig.com