HYRIG can supply the Z2S6 series hydraulic pilot-operated check valves. The Z2S6 is a size 6 modular sandwich valve designed for leak-free blocking of one or both work ports in vertical stacking assemblies. It is rated for 31.5 MPa working pressure and 63 L/min maximum flow.
Conatct For Details
DetailReview(0)Additional

HYRIG can supply the Z2S6 series hydraulic pilot-operated check valves. The Z2S6 is a size 6 modular sandwich valve designed for leak-free blocking of one or both work ports in vertical stacking assemblies. It is rated for 31.5 MPa working pressure and 63 L/min maximum flow.

Key Facts

  • Model: Z2S6
  • Nominal Size: 6 mm
  • Max Working Pressure: 31.5 MPa
  • Max Flow: 63 L/min
  • Pilot Ratio: 1 : 2.8
  • Sealing: Conical poppet, leak-free

Key Specifications & Ordering Codes

Data source: Technical data table.

ParameterZ2S6
Max Flow (L/min)63
Max Pressure (MPa)31.5
Pilot Ratio (A1-A2 : A3-A2)1 : 2.8
Weight (kg)0.8

Common Z2S6 ordering code formats (verify against your original nameplate):

Ordering Code FormatTypical Search TermNotes
Z2S6A1-64/Z2S6A1-64/ check valveSize 6, version A1, series 64
Z2S6-2-60B/VZ2S6-2-60B/V pilot valveSize 6, variant 2, series 60B, FKM seals
Z2S6A-1-6X/VZ2S6A-1-6X/VSize 6, A-port blocking, series 6X

Installation Dimensions

  • Mounting Type: Modular sandwich plate (vertical stacking)
  • Interface: Size 6 stacking pattern
  • Stacking Bolt Holes: 4 × Ø5.4 mm through-holes
  • Body Dimensions: 80 mm (L) × 44 mm (W) × 40 mm (H)
  • Sealing: O-rings between stacked plates (size 9.25 × 1.78 mm)

Structure / Working Principle

The Z2S6 uses a conical poppet with a compression spring to seal the work port in the reverse direction with zero leakage. In the free-flow direction (A→A1 or B→B1), fluid pushes the poppet open. To allow reverse flow, pilot pressure at port X acts on the control piston to mechanically lift the poppet off its seat. This makes the Z2S6 suitable for holding loads securely in vertical stacks without drift, even during prolonged standstill.

Cross-Reference & Replacement

Replacing a Z2S6 valve in an existing stack? Check these three points before ordering:

  1. Ordering code suffix — Z2S6A1-64/ and Z2S6-2-60B/V are not interchangeable without verifying the circuit function (A-port only, B-port only, or both ports blocked).
  2. Stacking interface — confirm the 4-hole bolt pattern and O-ring groove layout match your existing sandwich plate.
  3. Pilot pressure — the 1:2.8 pilot ratio means the pilot pressure must be at least 1/2.8 of the load-holding pressure to open the valve reliably.

Applications

Suitable for hydraulic systems that require leak-free holding of a load or prevention of load drop in vertical stacking assemblies. Commonly found in machine tool clamping circuits, hydraulic presses, and wind turbine braking systems.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Spare Parts

HYRIG can supply replacement O-rings and seal kits for the Z2S6 stacking interface. The standard O-ring size for the size 6 interface is 9.25 × 1.78 mm. Tell us your ordering code and required quantity, and we will confirm the seal compatibility.

Selection Support

Not sure whether the Z2S6 or a larger size (Z2S10/Z2S16) suits your flow and load-holding requirement? Share your circuit flow (L/min), load-holding pressure (MPa), and pilot pressure available — our engineers will help you match the correct size and ordering code.

Frequently Asked Questions

1. What does the “64” or “60B” suffix mean in Z2S6A1-64/ or Z2S6-2-60B/V?
These suffixes indicate the component series. The installation and connection dimensions remain unchanged within a series range (e.g., series 60 to 69). Always confirm the exact suffix against your original valve nameplate.

2. Can Z2S6 and Z2S10 be stacked together?
They use different nominal sizes (6 vs 10) and different stacking patterns. They are not directly interchangeable in the same stack without an adapter plate. Verify the interface before combining sizes.

3. Does the Z2S6 hold load with zero leakage?
Yes. The conical poppet design provides leak-free sealing in the blocked direction, making it suitable for long-term load holding without pressure drop.

4. What is the difference between Z2S6 and Z1S6?
Z1S6 is a standard stacked check valve (free flow in one direction, blocked in the other). Z2S6 is a pilot-operated check valve, meaning the reverse flow can be opened by applying pilot pressure.

5. How to troubleshoot if the Z2S6 pilot piston does not open the valve?
First, verify that the pilot pressure meets the 1:2.8 ratio requirement against the load pressure. Second, check if the control port (X) is clogged. Third, ensure the return line (if applicable) is vented to the tank.

Contact

For Z2S6 hydraulic pilot check valve selection and ordering code verification, contact HYRIG: info@hyrig.com