Z2S10 Hydraulic Pilot Check Valve | Z2S10-2-30B/V

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
HYRIG can supply the Z2S10 series hydraulic pilot-operated check valves. The Z2S10 is a size 10 modular sandwich valve designed for leak-free blocking of work ports. It handles up to 123 L/min and is rated for 31.5 MPa.
Conatct For Details
DetailReview(0)Additional

HYRIG can supply the Z2S10 series hydraulic pilot-operated check valves. The Z2S10 is a size 10 modular sandwich valve designed for leak-free blocking of work ports. It handles up to 123 L/min and is rated for 31.5 MPa.

Key Facts

  • Model: Z2S10
  • Nominal Size: 10 mm
  • Max Working Pressure: 31.5 MPa
  • Max Flow: 123 L/min
  • Pilot Ratio: 1 : 2.8

Key Specifications & Ordering Codes

Data source: Technical data table.

ParameterZ2S10
Max Flow (L/min)123
Max Pressure (MPa)31.5
Pilot Ratio1 : 2.8
Weight (kg)2.7

Common Z2S10 ordering code formats (verify against your original nameplate):

  • Z2S10-2-30B/V : Size 10, variant 2, series 30B, FKM seals.
  • Z2S10A-1-30B/ : Size 10, A-port blocking, series 30B.

Installation Dimensions

  • Mounting Type: Modular sandwich plate (vertical stacking)
  • Interface: Size 10 stacking pattern
  • Body Dimensions: 123 mm (L) × 70 mm (W) × 50 mm (H)
  • Stacking Bolt Holes: 4 × Ø6.5 mm through-holes

Structure / Working Principle

The Z2S10 uses a conical poppet and spring for leak-free sealing in the reverse direction. Free flow occurs from A→A1 or B→B1. Pilot pressure at port X mechanically opens the poppet for reverse flow, making it suitable for secure load holding in vertical stacks.

Cross-Reference & Replacement

Replacing a Z2S10? Confirm the stacking interface and the pilot ratio (1:2.8). Ensure the ordering code suffix matches your circuit function (e.g., A-port blocking vs. both ports blocked). The required pilot pressure must be at least 1/2.8 of the load pressure.

Applications

Used in machine tool clamping, hydraulic presses, and other vertical stacking systems requiring leak-free load holding.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Spare Parts

HYRIG can supply replacement O-rings and seal kits for the Z2S10 stacking interface (standard O-ring 12×2 mm).

Selection Support

Need a smaller or larger size? Explore the Z2S6 Hydraulic Pilot Check Valve or view all Hydraulic Check Valves.

Frequently Asked Questions

What does the V suffix mean?
The "V" suffix indicates FKM (Viton) seals, suitable for phosphate ester fluids or higher temperature applications.

What is the pilot ratio for Z2S10?
The pilot ratio is 1:2.8. Pilot pressure must exceed 1/2.8 of the load pressure to open the valve.

Can Z2S10 be used with Z2S6?
They have different nominal sizes (10 vs 6) and cannot be stacked directly without an adapter plate.

Contact

For Z2S10 hydraulic pilot check valve selection and ordering code verification, contact HYRIG: info@hyrig.com