The LY series is a vertical, single‑stage, single‑suction, volute type, radially split, long shaft submerged centrifugal pump manufactured in full compliance with API 610 11th Edition (ISO 13709) Type VS4. It is specifically designed for transferring molten urea (urea melt) in fertilizer plants, for prilling tower feed, and for granulation process.
The submerged design places the impeller and volute casing below the minimum liquid level in the melt pit or sump. This eliminates priming requirements, avoids suction lift issues, and ensures reliable start‑up even under low NPSH conditions.
Key Parameters (LY Series)
| Parameter | LY / LYO (Standard) | LYG (High Temperature) |
|---|---|---|
| Flow rate | 2 – 2,600 m³/h (with advanced double‑volute for sizes ≥80mm) | 3 – 2,600 m³/h |
| Total head | 5 – 250 m | 16 – 250 m |
| Operating temperature | -20°C to +120°C | Up to +400°C |
| Design pressure | Up to 1.6 MPa (standard), higher available up to 5.0 MPa | Up to 1.6 MPa |
| Working pressure | Up to 5.0 MPa | Up to 1.6 MPa |
| Immersion depth | Up to 7 m (standard; longer custom lengths available) | Standard |
Design Features
Submerged impeller with volute casing – pump always primed, no venting required at start‑up
Double volute casing (discharge sizes ≥80mm) – balances radial hydraulic forces, reduces shaft deflection and sliding bearing wear, extends service life
Steam jacket – integral heating jacket on casing and column pipe; circulates steam (≤0.6 MPa, up to 170°C) to maintain urea melt temperature above crystallization point and prevent solidification when pump is idle
Open impeller option – handles trace solids or minor deposits; semi‑open or enclosed impellers also available
Long line shaft with multi‑point bearings – uses sliding bearings inside column pipe and rolling bearings in bearing housing; external lubrication or self‑lubricating options; centralizers prevent shaft vibration in deep sumps
Rotor axial adjustability – adjustable nut allows precise clearance setting for optimal hydraulic efficiency
API 682 seal chamber (optional at discharge head) – no submerged dynamic seal, as impeller is fully submerged; single or double mechanical seals available for emission control if top seal is required
Discharge column – flanged sections for easy assembly and disassembly; separate discharge pipe construction eliminates leakage of pressurized liquid, shaft seal is not required in basic configuration
Materials of Construction
Urea solution and urea melt are moderately corrosive at high temperatures. Decomposition products (biuret, ammonia, carbamate) may increase corrosion. All wetted components shall be copper‑free to avoid material degradation.
| Component | Standard (Urea Melt) | Upgrade |
|---|---|---|
| Volute casing | 304SS or 316L stainless steel | Duplex 2205 / super duplex 2507 |
| Impeller | 304SS or 316L (open for solids handling) | Duplex / 12% Cr steel |
| Line shaft | AISI 416 stainless steel | 17-4PH / duplex |
| Column pipe | Carbon steel or 304SS (threaded / flanged) | 316SS / duplex |
| Discharge head | Cast iron / carbon steel (insulated) | 304SS / 316SS |
| Sliding bearings | PTFE‑lined bronze / rubber (water‑lubricated) | Silicon carbide / carbon |
| Gaskets / O‑rings | PTFE or EPDM | FFKM (Kalrez) |
Seal & Flush Plans
Standard configuration: no submerged shaft seal – eliminates leakage path at the bottom
Top seal (if specified): single mechanical seal with Plan 11
Zero‑leak requirement: tandem seal Plan 52 (unpressurized buffer fluid)
Hazardous / toxic service (if ammonia or carbamate present): double seal Plan 53B (pressurized barrier fluid)
Auxiliary Systems
Minimum flow protection – automatic recirculation valve (ARC) recommended
Steam jacket – low pressure steam ≤0.6 MPa at ≤170°C; connections on casing and column pipe
Bearing cooling – water‑cooled bearing housing for hot urea melt (>120°C) recommended
Insulation – thermal insulation on discharge head and exposed piping
Casing drain – low point drain for safe pit maintenance
Casing vent – high point vent for startup air removal
Baseplate / mounting flange – heavy duty fabricated flange bolted to pit cover or concrete support
Applications
Urea prilling tower feed pump – from melt pit to prilling tower top
Urea granulation feed pump – from evaporator to fluid bed or drum granulator
Molten urea transfer – between storage tank and finishing units
Urea solution transfer – for dilution or blending service (with lower temperature limits)
High temperature chemical services – hot oil, molten sulfur, molten paraffin (LYG version)
Why Choose LY Series for Urea Melt?
Full API 610 11th Edition (ISO 13709) Type VS4 compliance – heavy duty, reliable performance
Submerged impeller design – no priming, no suction lift issues, excellent low NPSH performance
Steam jacket standard – prevents urea crystallization during idle periods
Submerged bearing with no shaft seal – eliminates leakage risk for high‑temperature molten urea
Copper‑free materials – suitable for urea and fertilizer melt service
Customizable shaft length – fits any pit depth up to 7 meters (longer on request)
China manufacturer – competitive pricing, 20‑28 weeks lead time for standard stainless steel
Factory testing – hydraulic performance, mechanical run, hydrostatic test
Spare parts – wear rings, bearings, shaft sleeves, steam jackets, gaskets available
For more information or a custom proposal for your urea melt pump (LY VS4) application, contact us at info@hyrig.com