HYRIG can supply compatible replacements for the NOV manual and air-operated elevators, including A series center latch, G series 18° center latch, and X series side door elevators.
NOV is a registered trademark of National Oilwell Varco. HYRIG is an independent supplier of compatible replacement products and is not affiliated with, authorized by, or endorsed by National Oilwell Varco.
| Parameter | A Series | G Series | X Series |
|---|---|---|---|
| Type | Center Latch | 18° Center Latch | Side Door |
| Load Ratings | 35–350 sTon | 100–500 sTon | 100–350 sTon |
| Pipe Range | 1.050–11.1/4 in. | 2⅜–6⅝ in. | 4–7⅝ in. |
| Compliance | API 8C | API 8C | API 8C |
Data source: Technical data and parts list.
| Series | Max Load (sTon) | Max Pipe Size (in.) |
|---|---|---|
| A Series (TA) | 150 | 11¼ |
| G Series (GG/HGG) | 500 | 6⅝ |
| G Series (MGG) | 250 | 5½ |
| Dimension | A Series | G Series |
|---|---|---|
| Min Pipe Size | 1.050 in. | 2⅜ in. |
| Max Pipe Size | 11¼ in. | 6⅝ in. |
These elevators are designed to lift casing, tubing, and drill pipe. A series uses a center latch for collar-type pipe. G series uses an 18° taper for flush or upset pipe. Air-operated versions allow remote opening.
Looking to replace a NOV manual or air elevator? Check these points before ordering:
Used with standard rotary drilling rigs and traveling blocks.
Used for lifting and handling casing, tubing, and drill pipe during drilling operations.
Disclaimer: HYRIG supplies lifting equipment for industrial applications. Please verify local safety regulations and request valid certification documents before use. Never exceed the rated load capacity.
Not sure which elevator series fits your pipe? Tell us your pipe OD and string weight. Our engineers will verify the correct replacement before you order.
Q: Are these original NOV elevators?
A: No. HYRIG supplies independent, compatible replacement products and is not affiliated with NOV.
Q: What is the difference between A series and G series?
A: A series is a center latch for collar-type pipe. G series is an 18° center latch for flush or upset pipe.
Q: Are these elevators API 8C compliant?
A: Yes, they are designed and manufactured in strict accordance with ISO-API standard 8C.
Q: What is the typical lead time?
A: Lead time depends on configuration. Contact HYRIG for a confirmed delivery estimate.
For NOV manual and air-operated elevator compatible replacements, contact HYRIG: info@hyrig.com
NOV is a registered trademark of National Oilwell Varco. HYRIG is an independent supplier of compatible replacement products and is not affiliated with, authorized by, or endorsed by National Oilwell Varco.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.