REXROTH Z2S Pilot Check Valve Series
Overview:
HYRIG can supply the REXROTH Z2S series and related hydraulic components. These sandwich-mounted pilot-operated check valves allow free flow in one direction and blocked flow in the reverse direction, which can be released by pilot pressure.
| Model Code | Size | Blocking Channel | Cracking Pressure | Max Flow |
|---|---|---|---|---|
| Z2S6-1-6X/ | NG6 | A&B | 1.5 bar | 60 L/min |
| Z2S6A-*-6X/ | NG6 | A | 1.5–10 bar | 60 L/min |
| Z2S6B-*-6X/ | NG6 | B | 1.5–10 bar | 60 L/min |
| Z2S10-1-3X/ | NG10 | A&B | 1.5 bar | 120 L/min |
| Z2S16-1-5X/ | NG16 | A&B | 1.5 bar | 300 L/min |
Data source: REXROTH catalog and distributor listings.
For the NG6 standard A&B blocking with 1.5 bar cracking pressure, view REXROTH Z2S6-1-6X/.
Note: For Z2S16A--5X and Z2S16B--5X, the asterisk represents the cracking pressure code (1/2/3/4).
| Parameter | NG6 | NG10 | NG16 |
|---|---|---|---|
| Mounting Standard | ISO 4401-03 | ISO 4401-05 | ISO 4401-07 |
| Mounting Bolt Pattern | 4 × M5 | 4 × M6 | 4 × M10 |
| Approx. Weight | 1.2 kg | 2.8 kg | 5.5 kg |
The Z2S series requires matching both the blocking channel (A/B/A&B) and cracking pressure code (1/2/3/4). The component series (6X/3X/5X) indicates the design generation, with unchanged installation dimensions within each series.
Not sure which channel to block or which cracking pressure is correct for your pilot circuit? Contact HYRIG with your system parameters, and we will confirm the Z2S model code.
Used for load-holding, pilot-line isolation, and leakage-free blocking in hydraulic systems, particularly where a pilot signal is available to release the check valve. For the full range, view REXROTH Check Valves.
Disclaimer: REXROTH is a registered trademark of Bosch Rexroth AG. HYRIG is an independent supplier of hydraulic components and is not affiliated with Bosch Rexroth AG.
Specifications:
Contact Us:
For REXROTH Z2S series selection, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.