The SCSZ (Type BB4 single casing) and DCSZ (Type BB5 double casing barrel) series are self‑balancing multistage centrifugal pumps manufactured to API 610 10th Edition (ISO 13709). They are designed for high pressure boiler feed water (BFW) service in thermal power plants, combined cycle HRSG units, and industrial boiler systems.
Key Parameters
| Parameter | SCSZ (BB4) | DCSZ (BB5) |
|---|---|---|
| Flow rate | 5 – 730 m³/h | Up to 1,200 m³/h |
| Total head | Up to 2,800 m | Up to 3,400 m |
| Design pressure | Up to 30 MPa / 300 bar | Up to 35 MPa / 350 bar |
| Temperature | -80°C to +210°C | -80°C to +450°C |
| Flange rating | Class 600‑1500 | Class 1500‑2500 |
Design Features
Opposed impeller (back‑to‑back) arrangement – self‑balances axial thrust, eliminates balance disc/drum (common wear component)
Double suction first stage (optional) – reduces NPSH required for deaerator suction
Diffuser type casing – smooth hydraulics, high efficiency
Centerline support – uniform thermal expansion
Renewable wear rings and bushings – field replaceable
API 682 seal chamber – accepts single, tandem, or double seals
DCSZ: double casing with cartridge pull‑out – maintenance without disturbing outer barrel
Materials (Boiler Feed Water Service)
| Component | Standard | Upgrade |
|---|---|---|
| Outer barrel (DCSZ) | Forged carbon steel | Forged 316L SS |
| Inner casing / diffusers | Carbon steel or 304SS | 316L SS |
| Impellers | 12% Cr steel or 304SS | 316L SS |
| Shaft | AISI 4140 | 17-4PH |
| Wear rings | Hardened 12% Cr with Stellite | Silicon carbide |
Seal & Flush Plans
BFW <120°C: Single mechanical seal, Plan 11
BFW >120°C: Single seal with cooler, Plan 21 or Plan 23
Zero‑leak requirement: Tandem seal, Plan 52
Auxiliary Systems
Minimum flow protection – automatic recirculation valve (ARC) mandatory
Bearing cooling – water‑cooled housings for BFW >120°C
Baseplate – heavy duty steel, epoxy grouted, 2× API 610 nozzle loads
Applications
Boiler feed water for coal‑fired power plants (subcritical / supercritical)
HRSG feed pumps in combined cycle plants
Industrial package boiler feed
Biomass / waste‑to‑energy plant boiler feed
High pressure water injection
Why SCSZ/DCSZ for Boiler Feed?
API 610 compliance – heavy duty, 25‑year design life
Self‑balancing opposed impellers – eliminates balance disc wear, reduces maintenance
High pressure capability – up to 350 bar, covers supercritical applications
Low NPSH – double suction first stage protects against cavitation
China manufacturer – competitive price, 20‑30 week lead time
For more information, contact us at info@hyrig.com