SCSZ / DCSZ Boiler Feed Pump – API 610 BB4/BB5 Self-balancing Multistage Pump

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
SCSZ (BB4 single casing) and DCSZ (BB5 double casing barrel) self-balancing horizontal multistage centrifugal pumps to API 610 10th Ed. For boiler feed water in thermal power plants, industrial boilers, and HRSG units. Flow 5-1,200 m³/h, head to 3,400 m, pressure to 350 bar, temp to +450°C. Opposed impeller arrangement self-balances axial thrust, eliminating balance disc/drum. Double suction first stage for low NPSH. Single or double mechanical seals, carbon steel/12% Cr materials. Cartridge pull-out (DCSZ), centerline support.

Conatct For Details
DetailReview(0)Additional

The SCSZ (Type BB4 single casing) and DCSZ (Type BB5 double casing barrel) series are self‑balancing multistage centrifugal pumps manufactured to API 610 10th Edition (ISO 13709). They are designed for high pressure boiler feed water (BFW) service in thermal power plants, combined cycle HRSG units, and industrial boiler systems.

Key Parameters

ParameterSCSZ (BB4)DCSZ (BB5)
Flow rate5 – 730 m³/hUp to 1,200 m³/h
Total headUp to 2,800 mUp to 3,400 m
Design pressureUp to 30 MPa / 300 barUp to 35 MPa / 350 bar
Temperature-80°C to +210°C-80°C to +450°C
Flange ratingClass 600‑1500Class 1500‑2500

Design Features

  • Opposed impeller (back‑to‑back) arrangement – self‑balances axial thrust, eliminates balance disc/drum (common wear component)

  • Double suction first stage (optional) – reduces NPSH required for deaerator suction

  • Diffuser type casing – smooth hydraulics, high efficiency

  • Centerline support – uniform thermal expansion

  • Renewable wear rings and bushings – field replaceable

  • API 682 seal chamber – accepts single, tandem, or double seals

  • DCSZ: double casing with cartridge pull‑out – maintenance without disturbing outer barrel

Materials (Boiler Feed Water Service)

ComponentStandardUpgrade
Outer barrel (DCSZ)Forged carbon steelForged 316L SS
Inner casing / diffusersCarbon steel or 304SS316L SS
Impellers12% Cr steel or 304SS316L SS
ShaftAISI 414017-4PH
Wear ringsHardened 12% Cr with StelliteSilicon carbide

Seal & Flush Plans

  • BFW <120°C: Single mechanical seal, Plan 11

  • BFW >120°C: Single seal with cooler, Plan 21 or Plan 23

  • Zero‑leak requirement: Tandem seal, Plan 52

Auxiliary Systems

  • Minimum flow protection – automatic recirculation valve (ARC) mandatory

  • Bearing cooling – water‑cooled housings for BFW >120°C

  • Baseplate – heavy duty steel, epoxy grouted, 2× API 610 nozzle loads

Applications

  • Boiler feed water for coal‑fired power plants (subcritical / supercritical)

  • HRSG feed pumps in combined cycle plants

  • Industrial package boiler feed

  • Biomass / waste‑to‑energy plant boiler feed

  • High pressure water injection

Why SCSZ/DCSZ for Boiler Feed?

  • API 610 compliance – heavy duty, 25‑year design life

  • Self‑balancing opposed impellers – eliminates balance disc wear, reduces maintenance

  • High pressure capability – up to 350 bar, covers supercritical applications

  • Low NPSH – double suction first stage protects against cavitation

  • China manufacturer – competitive price, 20‑30 week lead time

For more information, contact us at info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit