The following index lists the major structural and mechanical components for the Shaffer Annular BOP. HYRIG provides direct OEM replacements for these parts to ensure reliable operation and long service life.
| Item / P/N | Description |
|---|---|
| 1 | Lower Housing - Flanged |
| 2 | Upper Housing - Studded |
| 3 | Piston Main Body |
| 4 | Adapter Ring |
| 5 | Sealing Element (Packing Element) |
| 15 | Wear Band (Piston & Adapter) |
| 17 | Pipe Plug |
| 18 | Anchor Shackle |
| 19 | Stud for Top API Flange |
| 20 | Nut for Top API Flange |
| Condition | Action |
|---|---|
| The adapter ring is sticking or scoring the piston | Replace the Wear Bands (Item 15) on both the piston and adapter ring. |
| The BOP is difficult to lift or move | Inspect the Anchor Shackles (Item 18) for wear or cracks before lifting. |
Common field error: Failing to replace the Wear Bands (Item 15) during a major overhaul. Worn wear bands can cause metal-to-metal contact, leading to catastrophic scoring of the piston and housing.
Email info@hyrig.com with:
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.