HYRIG can supply the Shaffer Gate Valves and spare parts. Shaffer gate valves are available in three basic models: Type B (handwheel), Type DB (hydraulic remote), and Type HB (hydraulic subsea), covering bore sizes from 2 1/16 in to 4 1/16 in and working pressures from 5,000 to 15,000 psi.
Conatct For Details
DetailReview(0)Additional

HYRIG can supply the Shaffer Gate Valves and spare parts. Shaffer gate valves are available in three basic models: Type B (handwheel), Type DB (hydraulic remote), and Type HB (hydraulic subsea), covering bore sizes from 2 1/16 in to 4 1/16 in and working pressures from 5,000 to 15,000 psi.

Key Facts

  • Models: Type B (handwheel), Type DB (hydraulic remote), Type HB (hydraulic subsea)
  • Bore Sizes: 2 1/16 in, 3 1/16 in, 3 1/8 in, 4 1/16 in
  • Working Pressure: 5,000 / 10,000 / 15,000 psi
  • Service: Standard, Internal H2S, low temperature, high temperature (350°F)
  • Standards: API 6A, NACE MR-01-75
  • Design: One-piece slab gate, downstream seal, body cavity grease-filled

Key Specifications

ModelOperationBore SizesWorking PressureTypical Application
Type BHandwheel2 1/16 in - 4 1/16 in5,000 / 10,000 / 15,000 psiChoke and kill manifold, isolation
Type DBHydraulic remote2 1/16 in - 4 1/16 in5,000 / 10,000 / 15,000 psiRemote-operated manifolds
Type HBHydraulic subsea2 1/16 in - 4 1/16 in5,000 / 10,000 / 15,000 psiSubsea BOP stack choke/kill lines

Data source: Technical data table.

Dimensions

ModelBore SizeWorking PressureEnd Connection
Type B2 1/16 in5,000 / 10,000 / 15,000 psiFlanged, Studded, Hubbed
Type B3 1/8 in5,000 / 10,000 / 15,000 psiFlanged, Studded, Hubbed
Type B4 1/16 in5,000 / 10,000 / 15,000 psiFlanged, Studded, Hubbed
Type DBSame as Type BSame as Type BSame as Type B
Type HBSame as Type BSame as Type BSame as Type B

For detailed dimensions (A, B, C, D, E, F) by size and pressure, contact HYRIG with your valve specifications.

Structure / Working Principle

Type B valves use a one-piece slab gate that seals fluids from either direction, with the seal always against the downstream seat and upstream pressure in the body cavity. This lowers handwheel torque. Type DB valves mount a hydraulic operator on a Type B body, allowing remote operation without welding. Type HB valves are designed for subsea applications with spring-return fail-safe closure and pressure-balanced tail rod. All models feature elastomeric seals, hardened and precision-ground gates and seats, and grease-filled body cavities to resist foreign materials.

Cross-Reference & Replacement

When replacing or selecting Shaffer gate valves, verify:

  1. Model - Type B, DB, or HB.
  2. Bore size - 2 1/16 in to 4 1/16 in.
  3. Working pressure - 5,000, 10,000, or 15,000 psi.
  4. End connection - Flanged, Studded, or Hubbed.
  5. Trim - Standard or H2S.
  6. Operation - Manual, hydraulic remote, or subsea hydraulic.

Applications

Shaffer gate valves are suitable for choke and kill manifold service, isolation valves on BOP stacks, and subsea BOP stack choke and kill lines. They are available for H2S service, low-temperature service, and high-temperature service up to 350°F.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Spare Parts

HYRIG provides replacement parts for Shaffer Gate Valves, including gates, seats, stem packing, tail rod packing, bonnet bolts, and hydraulic operator seals. Key wear components include:

  • Gate and seat assemblies
  • Stem packing (V-type)
  • Tail rod packing
  • Secondary plastic seals
  • Hydraulic cylinder seals

Contact HYRIG with the valve model, bore size, and pressure rating for a specific parts quotation.

Frequently Asked Questions

Q: What is the difference between Type B, DB, and HB? A: Type B is handwheel-operated; Type DB is hydraulic remote-operated; Type HB is hydraulic subsea with spring-return fail-safe.
Q: What is the maximum working pressure? A: 15,000 psi.
Q: Are H2S trim valves available? A: Yes, all models are available with H2S trim meeting API 6A and NACE.
Q: Can the valve be repaired in the field? A: Yes, no special tools are required and parts are interchangeable.
Q: What is the lead time? A: Contact HYRIG for current availability.

Selection Support

Need help selecting the right gate valve for your manifold or subsea stack? Tell us your bore size, pressure, and operation requirements, and HYRIG engineers will confirm the correct model. Explore related products: Shaffer BOP Control Systems or Shaffer Choke and Kill Manifolds.

Contact

For Shaffer Gate Valves selection and spare parts, contact HYRIG: info@hyrig.com

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit