| Condition | Action |
|---|---|
| BOP model is Shaffer LWS, 11" bore, 3M pressure | Direct fit for 1.315" pipe size |
| Well fluid contains H2S / CO2 | Available in HNBR / NBR sour-service trim (NACE MR0175) |
| BOP is SL, LXT, Cameron U, or Hydril | Not interchangeable. Requires different ram geometry |
Common field error: Ordering 1.315" based on nominal pipe OD without verifying the C.S.O. chart on the BOP door.
Email info@hyrig.com with: