A submersible sewage pump is a rugged centrifugal pump designed to operate fully submerged in raw wastewater, sewage, sludge, and industrial effluent. Unlike clean water pumps, sewage pumps are engineered to pass soft solids (rags, wipes, fecal matter, organic debris) and withstand abrasive particles without clogging. The motor is hermetically sealed, oil‑filled or water‑filled, and cooled by the surrounding liquid. The pump is typically installed in a wet well (lift station) or submersible pump pit, connected to guide rails for easy removal and maintenance.
These pumps are the backbone of municipal wastewater collection systems, industrial effluent treatment plants, flood control stations, and construction dewatering where solids are present.
| Impeller Type | Solids Handling | Efficiency | Best Application |
|---|---|---|---|
| Vortex (recessed) | Excellent – passes large, stringy solids without clogging | Lower (40‑60%) | Raw sewage, unscreened wastewater, high solid content |
| Channel (single or multi‑vane) | Good – passes moderate solids (up to 80mm) | Higher (60‑75%) | Screened sewage, sludge, industrial effluent |
| Semi‑open / multi‑vane | Moderate – for light solids | Medium‑high | Drainage with some debris, stormwater |
| Grinder | Reduces solids to small particles before pumping | Low | Pressure sewer systems with small diameter pipes |
For most raw sewage applications, the vortex impeller is preferred because the recessed design creates a whirlpool that draws solids into the pump without the impeller touching them – virtually eliminating clogging. For higher efficiency with screened sewage or sludge, a channel impeller provides better energy performance.
| Parameter | Range |
|---|---|
| Flow range | 5 – 2,000 m³/h (22 – 8,800 GPM) |
| Head range | 5 – 80 m (16 – 260 ft) |
| Motor power | 1.5 – 315 kW (2 – 420 HP) |
| Solids handling (vortex impeller) | Up to 80 mm (3″) spherical solids |
| Solids handling (channel impeller) | Up to 50 mm (2″) |
| Voltage / frequency | 400V / 50Hz or 460V / 60Hz three‑phase (single‑phase small units optional) |
| Speed | 1,450 / 2,900 rpm (50Hz) ; 1,750 / 3,500 rpm (60Hz) |
| Maximum submersion depth | 20 m (standard) , up to 50 m on request |
| Liquid temperature | 0 – 40°C (standard) , up to 90°C with special sealing |
| pH range | 5 – 9 (standard) ; wider with stainless steel |
| Protection class | IP68 (continuous submersion) |
| Insulation class | F or H |
| Motor cooling | Jacket cooling (standard) or external cooling shroud (dry well) |
| Component | Standard Material | Upgrade Option |
|---|---|---|
| Pump casing / volute | Cast iron (GG25 / ASTM A48) | Ductile iron, stainless steel 316 |
| Impeller (vortex or channel) | Cast iron (hardened) | Ni‑hard, stainless steel, high‑chrome alloy |
| Shaft | Stainless steel (AISI 420 / EN 1.4021) | AISI 316, duplex |
| Wear rings (if fitted) | Cast iron | Stainless steel, hard coating |
| Mechanical seal | Carbon / silicon carbide (oil‑cooled) | Silicon carbide / silicon carbide (for abrasives) |
| Fasteners | Stainless steel | – |
| Cable entry | Resin sealed with strain relief | – |
For aggressive industrial effluent (low pH, high chlorides) or abrasive sand‑laden sewage, select stainless steel or high‑chrome materials.
Submersible sewage pumps use a double mechanical seal arrangement with an intermediate oil chamber. This design is critical for reliability:
Lower seal (product‑side) – Silicon carbide vs. silicon carbide (hard faces) , immersed in the pumped liquid. Resists abrasion.
Upper seal (motor‑side) – Carbon vs. ceramic or silicon carbide, runs in clean oil.
Oil chamber – Contains dielectric oil that lubricates the seals, transfers heat, and provides a moisture barrier. A moisture sensor (probe) detects water ingress and alarms before motor damage.
This dual seal system allows the pump to handle abrasive and corrosive sewage while protecting the motor. For highly abrasive service, specify tungsten carbide vs. silicon carbide seals.
Fully submersible motor – IP68, tested at maximum depth.
Thermal sensors (PTC or thermistors) embedded in stator windings – trip motor if overheating.
Moisture sensor in oil chamber – alerts to seal failure.
Bearing temperature monitor (optional for large pumps).
Cooling system – Jacket cooling (heat transferred to pumped liquid) is standard; external cooling shroud required for dry pit installation or when pump is not fully submerged.
Motor protection class – Class F insulation (155°C) , Class H optional.
Vortex impeller design:
Impeller is recessed away from the flow path.
Creates a vortex that pulls solids through the pump without impeller contact.
Very low NPSHr.
Ideal for raw unscreened sewage, stringy materials (rags, wipes).
Efficiency is lower (40‑60%) but clog‑free operation reduces downtime.
Channel (single‑vane or multi‑vane) impeller:
Smooth, open channels for solids passage.
Higher efficiency (60‑75%) – reduces energy consumption.
Suitable for screened sewage, sludge, industrial effluent with moderate solids.
Available with wear‑resistant hard coating.
Grinder pump:
Cutter bar and impeller with sharp edges reduce solids to 6‑8 mm.
Used in pressure sewer systems (small diameter pipes) and low‑flow lift stations.
Most submersible sewage pumps are installed on a guide rail system in a wet well:
A fixed discharge base (elbow) is mounted at the bottom of the wet well, connected to the discharge pipe.
Guide rails (two pipes) run from the top of the well down to the base.
The pump is lowered onto the guide rails using a chain.
When the pump reaches the bottom, it automatically couples to the discharge base via a duck‑foot coupling.
To remove, pull up the chain; the pump disengages.
This system allows one person to remove a pump weighing hundreds of kilograms without entering the wet well.
| Application | Typical Pump Size | Impeller Type |
|---|---|---|
| Municipal wastewater lift station | 5 – 500 kW | Vortex (raw sewage) |
| Wastewater treatment plant (inlet / return sludge) | 10 – 200 kW | Channel (screened) or vortex |
| Industrial effluent pumping | 5 – 150 kW | Stainless steel vortex or channel |
| Flood control / stormwater pumping | 50 – 315 kW | Channel (high flow) |
| Construction dewatering (dirty water) | 1.5 – 30 kW | Semi‑open (small solids) |
| Portable sewage bypass pumping | 5 – 150 kW | Vortex (trailer‑mounted) |
| Pressure sewer system (grinder) | 1 – 5 kW | Grinder (cutter) |
Clog‑free operation – Vortex impeller eliminates clogging in raw sewage; channel impeller offers higher efficiency for screened applications.
Dual mechanical seals – Silicon carbide faces for long life; oil chamber with moisture sensor.
IP68 submersible motor – Thermal sensors, moisture probe, IP68 cable entry.
Guide rail system – Easy installation and removal; no well entry required.
Wide solids handling – Passes spherical solids up to 80 mm.
Corrosion / abrasion resistant options – Cast iron, stainless steel, high‑chrome impellers.
Efficient hydraulics – Optimised impeller and volute for lowest energy consumption.
ATEX certified – Available for explosive atmospheres (Zone 1, Zone 2).
VFD ready – Suitable for variable frequency drive operation (consult for minimum speed).
Global standards – CE, EN 12050 (wastewater lifting plants), NSF/ANSI 61 (potable water contact – for clean water versions).
Hydrostatic test – Casing tested at 1.5x maximum working pressure.
Performance test – Water at rated speed per ISO 9906 Grade 3 (or Grade 2 on request).
Mechanical run test – 1 hour minimum, including vibration and temperature check.
Electrical test – Insulation resistance, polarity, and hi‑pot test.
Seal integrity test – Oil chamber pressure‑tested before assembly.
Material certification – EN 10204 3.1 for wetted parts on request.
Wet well installation (standard):
Pump sits on guide rail base, fully submerged.
Ensure minimum submergence to avoid vortexing (see curve).
Provide high‑level and low‑level floats or ultrasonic level sensor.
Dry pit installation (optional):
Pump installed in a dry pump room with flooded suction.
External cooling shroud required for motor cooling.
Important operating rules:
Never run pump dry – seals and bearings will fail within minutes.
Do not start pump against a closed discharge valve for more than a few seconds.
Maintain minimum flow to avoid overheating (see manufacturer's curve for MCSF).
| Task | Frequency |
|---|---|
| Check motor current and vibration | Monthly |
| Inspect cable for damage | Annually (or when pump is pulled) |
| Check oil chamber moisture sensor | Each time pump is pulled |
| Change dielectric oil | 10,000 hours or 3 years (if no leaks) |
| Replace mechanical seals | When moisture alarm occurs or at major overhaul (20,000 hours) |
| Clean impeller and volute | As needed (when flow drops) |
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump does not start | No power, thermal overload tripped, control float stuck | Check breaker, thermal reset, float operation |
| Pump runs but no flow | Impeller clogged, check valve stuck, discharge line blocked | Pull pump; clean impeller; inspect check valve |
| Low flow / head | Worn impeller or wear rings, partial blockage | Inspect and replace worn parts; clean pump |
| Motor overload (overcurrent) | Impeller partially blocked, fluid density too high, phase loss | Clean impeller; check fluid; verify supply |
| Moisture alarm | Mechanical seal leak | Pull pump; replace seals; change oil |
| Excessive vibration | Impeller clogged or damaged, bearing wear | Clean or replace impeller; check bearings |
| Component | Recommended Quantity |
|---|---|
| Mechanical seal set (lower + upper) | 1 set |
| Impeller (vortex or channel) | 1 |
| Wear ring set (if fitted) | 1 set |
| Oil chamber gasket / O‑ring kit | 1 set |
| Moisture sensor probe | 1 |
| Cable (complete with connector) | 1 (for spare) |
Reliable clog‑free operation – Vortex impeller handles rags and wipes without failure.
Dual silicon carbide seals – Proven in abrasive sewage service, long life.
IP68 fully submersible – No risk of flood damage.
Easy guide rail installation – One‑person removal and replacement.
Wide range – Flows to 2,000 m³/h, heads to 80 m, powers to 315 kW.
Corrosion‑resistant options – Stainless steel for aggressive industrial waste.
ATEX available – For explosive environments like methane‑rich sewage.
Global support – Spare parts and field service worldwide.
For detailed selection of the correct submersible sewage pump – including flow/head requirements, solids size and type, wet well dimensions, power supply, and materials – please contact our engineering team.
Email: info@hyrig.com
Our engineers support municipal wastewater, industrial effluent, and flood control projects worldwide with reliable, clog‑resistant submersible sewage pumps – built for the toughest solids and longest service life.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.