Vertical In-line Pump – API 610 OH3 / OH4 Direct‑Connected Centrifugal Pump for Space‑Saving Applications

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Vertical in-line pump (direct‑coupled, single‑stage centrifugal) with suction and discharge flanges aligned on a vertical axis. Available in standard industrial or API 610 OH3/OH4 configurations. Cast iron, 316L SS or duplex. Flows to 1,500 m³/h, heads to 150 m, temperatures to 150°C. Compact footprint, easy maintenance, back pull‑out design. Ideal for HVAC chilled/hot water, industrial circulation, water boosting, and process transfer.

Conatct For Details
DetailReview(0)Additional

Product Overview

The vertical in-line pump is a single‑stage, single‑suction centrifugal pump with suction and discharge flanges aligned on a vertical axis – allowing the pump to be installed directly into a pipeline without the need for a separate baseplate or foundation. The motor is mounted vertically on top of the pump, and the impeller is overhung directly on the motor shaft (close‑coupled) or on an extended pump shaft coupled to the motor (rigid‑coupled). This design occupies a very small footprint and is ideal for installations where floor space is limited – mechanical rooms, boiler houses, high‑rise building plant rooms, and retrofits.

Within API 610 (ISO 13709) classification, vertical in‑line pumps fall into two types:

  • OH3 – Vertical in‑line, single‑stage, overhung, with a rigid coupling (motor and pump have separate shafts, connected by a flexible or rigid coupling).

  • OH4 – Vertical in‑line, single‑stage, overhung, close‑coupled (impeller mounted directly on the motor shaft extension).

Both configurations offer back pull‑out maintenance: the rotating assembly can be withdrawn upward without disturbing the piping, leaving the casing in the pipeline.

Pump Configurations – Standard vs. API 610

FeatureStandard IndustrialAPI 610 OH3 / OH4
CasingRadially split, single casingRadially split, heavy‑duty casing
MountingIn‑line (supported by pipe flanges)In‑line with sturdy support feet (OH3) or close‑coupled (OH4)
Design life10‑15 years20 years minimum
Continuous operationIntermittent or continuous≥3 years uninterrupted
MaterialsCast iron, 304/316L SSAPI 610 Table H (S‑8, D‑1/D‑2, C‑6)
Bearing lifeL10 ≥17,500 hoursL10 ≥25,000 hours
Seal chamberStandard gland or cartridgeAPI 682 certified
Ideal forHVAC, water boosting, general industryRefinery, petrochemical, offshore, NACE service

Key Technical Specifications

ParameterStandard IndustrialAPI 610 OH3/OH4
Flow range5 – 1,500 m³/h (22 – 6,600 GPM)10 – 600 m³/h
Head range5 – 150 m (16 – 490 ft)10 – 150 m
Pressure ratingUp to 16 bar (230 psi)Up to 40 bar (580 psi)
Temperature range–20 to +120°C (–4 to +248°F)–45 to +200°C (–49 to +392°F)
Speed1,450 / 2,900 rpm (50Hz) ; 1,750 / 3,500 rpm (60Hz)1,450 / 2,950 rpm
Motor power0.55 – 200 kW (0.75 – 270 HP)2.2 – 200 kW
MaterialsCast iron, 304 SS, 316L SS316L SS (S‑8), duplex (D‑1/D‑2), carbon steel (C‑6)
ConnectionsFlanged (DIN/ANSI) , threaded (small)ANSI / ASME raised face flanges

Materials – Corrosion & Wear Resistance

ComponentStandard (Cast Iron)Premium (316L SS)API 610 (S‑8 / Duplex)
CasingCast iron (GG25) with epoxy coating316L stainless steel (CF3M)316L SS or duplex
ImpellerCast iron or bronze316L SS316L SS, 17‑4 PH, duplex
Shaft2Cr13 or AISI 420 stainless steel316 SS17‑4 PH, duplex
Mechanical sealCarbon/ceramic/NBRSilicon carbide/VitonAPI 682 cartridge, SiC/SiC, Viton/Aflas
FastenersZinc‑plated steel304 SS316 SS / duplex
GasketsNon‑asbestos or EPDMPTFE or VitonSpiral wound graphite / PTFE

For potable water, cast iron with epoxy coating is acceptable. For seawater, chemical service, or high‑purity water, specify 316L stainless steel. For chloride‑rich or sour environments, duplex (D‑1/D‑2) with NACE MR0175 is required.

Hydraulic Design – High Efficiency & Low NPSH

The vertical in‑line pump features:

  • Single‑stage, single‑suction radial impeller – closed (enclosed) for clean liquids, semi‑open for light solids.

  • Volute casing with optimized cross‑section for smooth flow and high efficiency (up to 85%).

  • Large impeller eye – reduces NPSHr; typical NPSHr of 2‑5 m at BEP.

  • Steep, stable head‑flow curve – continuously rising to shut‑off, suitable for parallel operation.

  • Balanced axial thrust – hydraulic thrust is absorbed by a thrust bearing in the motor (close‑coupled) or in the pump bearing housing (OH3). Some designs use balance holes or back vanes.

Mechanical Seal – API 682 Compliant Options

ServiceSeal TypeAPI 682 PlanMaterials
Clean cold waterSingle cartridgePlan 11Carbon / ceramic / NBR
Hot water (≤120°C)Single with coolerPlan 23 (recirculation cooler)Silicon carbide / carbon / Viton
Chemical transferSingle (SiC/SiC)Plan 11 or 32Silicon carbide / silicon carbide / Viton
Hydrocarbon / hazardousDual pressurisedPlan 53BSilicon carbide / silicon carbide / Viton or Aflas
Food / sanitarySingle (FDA)Plan 11Carbon / ceramic / EPDM

The API 610 OH3/OH4 pump features an API 682 seal chamber (dimensions per ASME B73.2 or ISO 21049) , accepting any cartridge seal arrangement without modification.

Applications – Where the Vertical In‑line Pump Excels

IndustryApplicationWhy Vertical In‑line
HVACChilled water circulation, hot water heating, condenser waterSpace‑saving in mechanical rooms; in‑line installation
Water boostingHigh‑rise building pressure boosting, municipal booster stationsCompact, low noise, easy to install in risers
Industrial waterCooling tower circulation, process water, wash‑downReliable, low maintenance, stainless option
Chemical / petrochemicalChemical transfer, API 610 OH3 for light hydrocarbonsCorrosion‑resistant materials, heavy‑duty bearings
Food & beverageCIP supply, product transfer (sanitary version)Stainless steel, easy‑clean, FDA elastomers
PharmaceuticalPurified water (PW) , water for injection (WFI)Electropolished 316L, sanitary connections
IrrigationCenter pivot, sprinkler systemsEnergy efficient, corrosion‑resistant options
Marine / offshoreSeawater cooling, firewater (duplex)Compact, NACE MR0175, duplex stainless

Key Features – Why Choose Our Vertical In‑line Pump

  • Space‑saving design – Installs directly into the pipeline; no baseplate or foundation required. Floor space savings of 50‑70% compared to horizontal pumps.

  • In‑line piping – Suction and discharge flanges are aligned vertically; pipe supports alone can hold the pump (though additional support is recommended for large sizes).

  • Easy maintenance – Back pull‑out design: remove the motor and rotating assembly upward without disturbing the casing or piping.

  • Low noise – Vertical design with rigid mounting reduces vibration; standard noise <75 dB(A) , premium <70 dB(A).

  • High efficiency – Hydraulically optimised closed impeller and volute achieve IE3/IE4 motor efficiency.

  • Wide material selection – Cast iron, 304 SS, 316L SS, duplex, super duplex, with NACE MR0175.

  • Seal flexibility – Single, tandem, or dual pressurised seals; all API 682 plans supported.

  • VFD ready – Suitable for variable frequency drive operation (consult for minimum speed limits).

  • Certified for potable water – WRAS, NSF/ANSI 61 available.

  • ATEX option – For hazardous areas (Zone 1, Zone 2) on request.

Quality Assurance and Testing

TestStandard IndustrialAPI 610 OH3/OH4
Hydrostatic test1.5x design pressure (casing)1.5x MAWP
Performance testISO 9906 Grade 3API 610 Grade 2 or 1
Mechanical run1 hourMinimum 4 hours
NPSH testOptionalFull verification if specified
Material certificationEN 10204 2.2 (or 3.1 on request)EN 10204 3.1 mandatory
NDEVisual onlyMPI, dye penetrant, or radiography as required
NACE MR0175Not requiredAvailable on request

Installation and Operation

Advantages over horizontal pumps:

  • The pump hangs in the pipeline, so no heavy baseplate or grouting.

  • Suction and discharge flanges are at the same elevation, simplifying layout.

  • The motor is above the pump, keeping it dry if the floor floods.

Installation notes:

  • Support the piping independently near the pump to avoid excessive loads on the flanges.

  • For large or heavy units, use a support bracket or floor stand.

  • Ensure the pump is vertical (use a spirit level on the motor flange).

  • Provide a strainer on the suction side if debris is possible.

  • For hot service, allow for thermal expansion of the pipework.

Operation:

  • Prime the pump by ensuring the suction pipe is flooded (centrifugal pumps are not self‑priming unless specified).

  • Close discharge valve, start motor, then slowly open discharge valve.

  • Never run dry – even a few seconds damages the mechanical seal.

Maintenance

TaskFrequency
Check mechanical seal for leaksMonthly
Listen for unusual noise or vibrationWeekly
Check motor current and temperatureMonthly
Replace mechanical seal8,000‑12,000 hours or when leaking
Lubricate motor bearings (if grease‑fitted)Every 6 months
Inspect impeller and wear rings20,000 hours or 3 years

Removing rotating assembly (back pull‑out):

  1. Isolate pump, drain casing.

  2. Disconnect motor electrical leads.

  3. Remove bolts between casing and bearing housing / motor adapter.

  4. Lift the motor and rotating assembly vertically out of the casing.

  5. Service seal, impeller, or bearings on the bench.

  6. Reassembly is the reverse.

Troubleshooting

ProblemLikely CauseSolution
Pump doesn't deliver waterNot primed, suction valve closed, impeller blockedPrime; open valve; clean impeller
Low flow / pressureWorn wear rings, air in suction, discharge valve partially closedReplace wear rings; vent air; open discharge valve
Excessive power consumptionFluid density or viscosity too high, flow too high (right on curve)Check fluid properties; throttle discharge
VibrationCavitation, misalignment, impeller imbalanceIncrease NPSHa; check vertical alignment; balance impeller
Seal leaksWorn faces, wrong elastomer, dry runningReplace seal; verify materials; ensure flooded suction
Motor overheatsRun dry, high ambient, voltage imbalanceEnsure priming; clean motor vents; check supply

Recommended Spare Parts (Per Pump)

ComponentRecommended Quantity
Mechanical seal cartridge (complete)1 set
Bearing set (if separate pump bearings)1 set (for OH3)
Wear ring set (if fitted)1 set
Gasket / O‑ring kit (full)1 set
Impeller (for critical duty)1

Why Choose Our Vertical In‑line Pump?

  • Space‑saving – Installs in‑line, no baseplate, minimal footprint – ideal for plant rooms and retrofits.

  • Easy maintenance – Back pull‑out design allows service without breaking pipe joints.

  • API 610 OH3/OH4 option – For heavy‑duty, 20‑year life, critical service applications.

  • Wide hydraulic range – Covers flows from 5 to 1,500 m³/h, heads to 150 m.

  • Material flexibility – Cast iron, 316L SS, duplex, NACE MR0175.

  • Seal flexibility – API 682 plans 11, 21, 23, 52, 53B.

  • High efficiency – Hydraulically optimised, meets IE3/IE4 motor efficiency.

  • Low NPSH – Large impeller eye reduces cavitation risk.

  • Potable water certified – WRAS, NSF available.

  • Global support – Spare parts and technical assistance worldwide.

Get a Quote or Engineering Support

For detailed selection of the correct vertical in‑line pump – including flow/head requirements, fluid properties, material grade (cast iron, 316L SS, duplex), API 610 OH3/OH4 requirement, seal plan, and electrical specifications – please contact our engineering team.

Email: info@hyrig.com

Our engineers support HVAC, water boosting, industrial circulation, and chemical transfer projects worldwide with reliable, space‑saving vertical in‑line pumps – easy to install, easy to maintain, built for long service life.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code