The vertical in-line pump is a single‑stage, single‑suction centrifugal pump with suction and discharge flanges aligned on a vertical axis – allowing the pump to be installed directly into a pipeline without the need for a separate baseplate or foundation. The motor is mounted vertically on top of the pump, and the impeller is overhung directly on the motor shaft (close‑coupled) or on an extended pump shaft coupled to the motor (rigid‑coupled). This design occupies a very small footprint and is ideal for installations where floor space is limited – mechanical rooms, boiler houses, high‑rise building plant rooms, and retrofits.
Within API 610 (ISO 13709) classification, vertical in‑line pumps fall into two types:
OH3 – Vertical in‑line, single‑stage, overhung, with a rigid coupling (motor and pump have separate shafts, connected by a flexible or rigid coupling).
OH4 – Vertical in‑line, single‑stage, overhung, close‑coupled (impeller mounted directly on the motor shaft extension).
Both configurations offer back pull‑out maintenance: the rotating assembly can be withdrawn upward without disturbing the piping, leaving the casing in the pipeline.
| Feature | Standard Industrial | API 610 OH3 / OH4 |
|---|---|---|
| Casing | Radially split, single casing | Radially split, heavy‑duty casing |
| Mounting | In‑line (supported by pipe flanges) | In‑line with sturdy support feet (OH3) or close‑coupled (OH4) |
| Design life | 10‑15 years | 20 years minimum |
| Continuous operation | Intermittent or continuous | ≥3 years uninterrupted |
| Materials | Cast iron, 304/316L SS | API 610 Table H (S‑8, D‑1/D‑2, C‑6) |
| Bearing life | L10 ≥17,500 hours | L10 ≥25,000 hours |
| Seal chamber | Standard gland or cartridge | API 682 certified |
| Ideal for | HVAC, water boosting, general industry | Refinery, petrochemical, offshore, NACE service |
| Parameter | Standard Industrial | API 610 OH3/OH4 |
|---|---|---|
| Flow range | 5 – 1,500 m³/h (22 – 6,600 GPM) | 10 – 600 m³/h |
| Head range | 5 – 150 m (16 – 490 ft) | 10 – 150 m |
| Pressure rating | Up to 16 bar (230 psi) | Up to 40 bar (580 psi) |
| Temperature range | –20 to +120°C (–4 to +248°F) | –45 to +200°C (–49 to +392°F) |
| Speed | 1,450 / 2,900 rpm (50Hz) ; 1,750 / 3,500 rpm (60Hz) | 1,450 / 2,950 rpm |
| Motor power | 0.55 – 200 kW (0.75 – 270 HP) | 2.2 – 200 kW |
| Materials | Cast iron, 304 SS, 316L SS | 316L SS (S‑8), duplex (D‑1/D‑2), carbon steel (C‑6) |
| Connections | Flanged (DIN/ANSI) , threaded (small) | ANSI / ASME raised face flanges |
| Component | Standard (Cast Iron) | Premium (316L SS) | API 610 (S‑8 / Duplex) |
|---|---|---|---|
| Casing | Cast iron (GG25) with epoxy coating | 316L stainless steel (CF3M) | 316L SS or duplex |
| Impeller | Cast iron or bronze | 316L SS | 316L SS, 17‑4 PH, duplex |
| Shaft | 2Cr13 or AISI 420 stainless steel | 316 SS | 17‑4 PH, duplex |
| Mechanical seal | Carbon/ceramic/NBR | Silicon carbide/Viton | API 682 cartridge, SiC/SiC, Viton/Aflas |
| Fasteners | Zinc‑plated steel | 304 SS | 316 SS / duplex |
| Gaskets | Non‑asbestos or EPDM | PTFE or Viton | Spiral wound graphite / PTFE |
For potable water, cast iron with epoxy coating is acceptable. For seawater, chemical service, or high‑purity water, specify 316L stainless steel. For chloride‑rich or sour environments, duplex (D‑1/D‑2) with NACE MR0175 is required.
The vertical in‑line pump features:
Single‑stage, single‑suction radial impeller – closed (enclosed) for clean liquids, semi‑open for light solids.
Volute casing with optimized cross‑section for smooth flow and high efficiency (up to 85%).
Large impeller eye – reduces NPSHr; typical NPSHr of 2‑5 m at BEP.
Steep, stable head‑flow curve – continuously rising to shut‑off, suitable for parallel operation.
Balanced axial thrust – hydraulic thrust is absorbed by a thrust bearing in the motor (close‑coupled) or in the pump bearing housing (OH3). Some designs use balance holes or back vanes.
| Service | Seal Type | API 682 Plan | Materials |
|---|---|---|---|
| Clean cold water | Single cartridge | Plan 11 | Carbon / ceramic / NBR |
| Hot water (≤120°C) | Single with cooler | Plan 23 (recirculation cooler) | Silicon carbide / carbon / Viton |
| Chemical transfer | Single (SiC/SiC) | Plan 11 or 32 | Silicon carbide / silicon carbide / Viton |
| Hydrocarbon / hazardous | Dual pressurised | Plan 53B | Silicon carbide / silicon carbide / Viton or Aflas |
| Food / sanitary | Single (FDA) | Plan 11 | Carbon / ceramic / EPDM |
The API 610 OH3/OH4 pump features an API 682 seal chamber (dimensions per ASME B73.2 or ISO 21049) , accepting any cartridge seal arrangement without modification.
| Industry | Application | Why Vertical In‑line |
|---|---|---|
| HVAC | Chilled water circulation, hot water heating, condenser water | Space‑saving in mechanical rooms; in‑line installation |
| Water boosting | High‑rise building pressure boosting, municipal booster stations | Compact, low noise, easy to install in risers |
| Industrial water | Cooling tower circulation, process water, wash‑down | Reliable, low maintenance, stainless option |
| Chemical / petrochemical | Chemical transfer, API 610 OH3 for light hydrocarbons | Corrosion‑resistant materials, heavy‑duty bearings |
| Food & beverage | CIP supply, product transfer (sanitary version) | Stainless steel, easy‑clean, FDA elastomers |
| Pharmaceutical | Purified water (PW) , water for injection (WFI) | Electropolished 316L, sanitary connections |
| Irrigation | Center pivot, sprinkler systems | Energy efficient, corrosion‑resistant options |
| Marine / offshore | Seawater cooling, firewater (duplex) | Compact, NACE MR0175, duplex stainless |
Space‑saving design – Installs directly into the pipeline; no baseplate or foundation required. Floor space savings of 50‑70% compared to horizontal pumps.
In‑line piping – Suction and discharge flanges are aligned vertically; pipe supports alone can hold the pump (though additional support is recommended for large sizes).
Easy maintenance – Back pull‑out design: remove the motor and rotating assembly upward without disturbing the casing or piping.
Low noise – Vertical design with rigid mounting reduces vibration; standard noise <75 dB(A) , premium <70 dB(A).
High efficiency – Hydraulically optimised closed impeller and volute achieve IE3/IE4 motor efficiency.
Wide material selection – Cast iron, 304 SS, 316L SS, duplex, super duplex, with NACE MR0175.
Seal flexibility – Single, tandem, or dual pressurised seals; all API 682 plans supported.
VFD ready – Suitable for variable frequency drive operation (consult for minimum speed limits).
Certified for potable water – WRAS, NSF/ANSI 61 available.
ATEX option – For hazardous areas (Zone 1, Zone 2) on request.
| Test | Standard Industrial | API 610 OH3/OH4 |
|---|---|---|
| Hydrostatic test | 1.5x design pressure (casing) | 1.5x MAWP |
| Performance test | ISO 9906 Grade 3 | API 610 Grade 2 or 1 |
| Mechanical run | 1 hour | Minimum 4 hours |
| NPSH test | Optional | Full verification if specified |
| Material certification | EN 10204 2.2 (or 3.1 on request) | EN 10204 3.1 mandatory |
| NDE | Visual only | MPI, dye penetrant, or radiography as required |
| NACE MR0175 | Not required | Available on request |
Advantages over horizontal pumps:
The pump hangs in the pipeline, so no heavy baseplate or grouting.
Suction and discharge flanges are at the same elevation, simplifying layout.
The motor is above the pump, keeping it dry if the floor floods.
Installation notes:
Support the piping independently near the pump to avoid excessive loads on the flanges.
For large or heavy units, use a support bracket or floor stand.
Ensure the pump is vertical (use a spirit level on the motor flange).
Provide a strainer on the suction side if debris is possible.
For hot service, allow for thermal expansion of the pipework.
Operation:
Prime the pump by ensuring the suction pipe is flooded (centrifugal pumps are not self‑priming unless specified).
Close discharge valve, start motor, then slowly open discharge valve.
Never run dry – even a few seconds damages the mechanical seal.
| Task | Frequency |
|---|---|
| Check mechanical seal for leaks | Monthly |
| Listen for unusual noise or vibration | Weekly |
| Check motor current and temperature | Monthly |
| Replace mechanical seal | 8,000‑12,000 hours or when leaking |
| Lubricate motor bearings (if grease‑fitted) | Every 6 months |
| Inspect impeller and wear rings | 20,000 hours or 3 years |
Removing rotating assembly (back pull‑out):
Isolate pump, drain casing.
Disconnect motor electrical leads.
Remove bolts between casing and bearing housing / motor adapter.
Lift the motor and rotating assembly vertically out of the casing.
Service seal, impeller, or bearings on the bench.
Reassembly is the reverse.
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump doesn't deliver water | Not primed, suction valve closed, impeller blocked | Prime; open valve; clean impeller |
| Low flow / pressure | Worn wear rings, air in suction, discharge valve partially closed | Replace wear rings; vent air; open discharge valve |
| Excessive power consumption | Fluid density or viscosity too high, flow too high (right on curve) | Check fluid properties; throttle discharge |
| Vibration | Cavitation, misalignment, impeller imbalance | Increase NPSHa; check vertical alignment; balance impeller |
| Seal leaks | Worn faces, wrong elastomer, dry running | Replace seal; verify materials; ensure flooded suction |
| Motor overheats | Run dry, high ambient, voltage imbalance | Ensure priming; clean motor vents; check supply |
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (complete) | 1 set |
| Bearing set (if separate pump bearings) | 1 set (for OH3) |
| Wear ring set (if fitted) | 1 set |
| Gasket / O‑ring kit (full) | 1 set |
| Impeller (for critical duty) | 1 |
Space‑saving – Installs in‑line, no baseplate, minimal footprint – ideal for plant rooms and retrofits.
Easy maintenance – Back pull‑out design allows service without breaking pipe joints.
API 610 OH3/OH4 option – For heavy‑duty, 20‑year life, critical service applications.
Wide hydraulic range – Covers flows from 5 to 1,500 m³/h, heads to 150 m.
Material flexibility – Cast iron, 316L SS, duplex, NACE MR0175.
Seal flexibility – API 682 plans 11, 21, 23, 52, 53B.
High efficiency – Hydraulically optimised, meets IE3/IE4 motor efficiency.
Low NPSH – Large impeller eye reduces cavitation risk.
Potable water certified – WRAS, NSF available.
Global support – Spare parts and technical assistance worldwide.