A submersible slurry pump is a rugged, abrasion‑resistant centrifugal pump designed to operate fully submerged in highly abrasive, high‑density slurries – mixtures of water with sand, gravel, tailings, ore fines, ash, or other solid particles. Unlike standard dewatering or sewage pumps, slurry pumps are built with hardened materials (high‑chrome alloy or natural rubber) to withstand erosive wear. They feature open impellers with wide passages to avoid clogging, and often include an agitator (expeller) to stir settled solids into suspension.
These pumps are indispensable in mining (dewatering, tailings transfer), dredging (river, harbour, pond cleaning), industrial minerals processing, power plant ash handling, and civil foundation works where sand and gravel are present.
| Feature | Submersible Slurry Pump | Dewatering Pump |
|---|---|---|
| Primary service | High density, abrasive solids | Sand, silt, dirty water (low to medium abrasion) |
| Max solids size | Up to 50‑100 mm | Up to 25‑50 mm |
| Max density | Up to 2.0 t/m³ (60‑70% solids by weight) | Up to 1.2 t/m³ (10‑20% solids) |
| Wear parts material | High‑chrome alloy (≥550 BHN) or rubber | Cast iron or hardened iron |
| Impeller type | Open (vane) with agitator | Semi‑open or open |
| Hydraulic design | Low speed (980‑1,450 rpm) for wear life | Higher speed (1,450‑2,900 rpm) |
| Parameter | Small / Portable | Medium | Large / Heavy‑Duty |
|---|---|---|---|
| Flow range | 10 – 100 m³/h | 100 – 500 m³/h | 500 – 1,200 m³/h |
| Head range | 5 – 30 m | 10 – 60 m | 20 – 80 m |
| Motor power | 3 – 22 kW | 30 – 90 kW | 110 – 315 kW |
| Max solids size | Up to 25 mm | Up to 50 mm | Up to 100 mm |
| Max slurry density | 1.3 t/m³ | 1.6 t/m³ | 2.0 t/m³ |
| Discharge size | 2″ – 4″ | 6″ – 8″ | 10″ – 12″ |
| Speed | 1,450 / 2,900 rpm | 980 / 1,450 rpm | 740 / 980 rpm |
| Voltage / frequency | 400V / 50Hz three‑phase | 400‑690V / 50Hz | 3.3kV / 6.6kV / 50Hz (high voltage) |
| Component | Standard (High‑Chrome) | Rubber Lined | Extreme Duty |
|---|---|---|---|
| Casing / volute | High‑chrome iron (Cr27‑Cr30) | Natural rubber bonded to steel | Ceramic tile or hard metal cladding |
| Impeller | High‑chrome iron (Cr27) | Rubber covered or natural rubber | Tungsten carbide tipped |
| Wear plate / suction plate | High‑chrome iron | Rubber lined | High‑chrome + ceramic inserts |
| Shaft sleeve | Hard chrome plated | Hard chrome plated | Tungsten carbide |
| Mechanical seal | Silicon carbide / silicon carbide (oil‑cooled) | Silicon carbide / silicon carbide | Tungsten carbide / silicon carbide |
High‑chrome alloy (Cr27‑Cr30) is the industry standard for highly abrasive slurries – hardness 55‑65 HRC, excellent erosion resistance. Rubber lining is used when the slurry is mildly abrasive but also corrosive (e.g., acidic tailings) – rubber absorbs impact and resists chemical attack. For extreme duty (sharp particles, high velocity), specify tungsten carbide inserts.
Open (vane) impeller – No front shroud, wide passages. The impeller vanes run close to a replaceable wear plate. As the plate erodes, clearance increases, but performance can be restored by adjusting the impeller downward (or replacing the wear plate). Open impellers are self‑cleaning and allow large solids to pass.
Agitator (expeller / stirring device) – A small secondary impeller or protrusion mounted on the pump bottom, below the main impeller. The agitator rotates with the shaft and stirs settled solids at the bottom of the sump into suspension, allowing the main impeller to pump them. Without an agitator, the pump would only pump clear water from above the settled layer.
Types of agitators:
Bottom agitator – A single or double blade extends below the suction plate; spins and creates turbulence to lift settled solids.
Jet agitator – A nozzle directs a portion of the pump discharge downward to stir solids.
For dredging and tailings pond cleaning, an agitator is essential.
| Seal Position | Material | Function |
|---|---|---|
| Lower seal (product side) | Silicon carbide vs. silicon carbide (or tungsten carbide) | Seals against the abrasive slurry |
| Upper seal (motor side) | Carbon vs. ceramic or silicon carbide | Seals against clean oil in chamber |
| Oil chamber | Dielectric oil | Lubricates seals, transfers heat, contains moisture sensor |
For extreme abrasive service, specify tungsten carbide vs. tungsten carbide seal faces – they are harder (80‑85 HRC) and last much longer in sand and grit.
Submersible motor – IP68, fully sealed.
Cooling – Jacket cooling (heat transferred to pumped slurry). Some models require an external cooling shroud for dry pit installation.
Protection – Thermal sensors (PTC) in stator, moisture sensor in oil chamber, bearing temperature monitor (optional).
Voltage – Low voltage (400‑690V) for smaller pumps; medium voltage (3.3kV, 6.6kV) for large pumps (200 kW+).
Frequency – 50Hz or 60Hz.
High voltage submersible slurry pumps are common in mines – they avoid long low‑voltage cables (voltage drop) and allow direct connection to mine power.
Without an agitator, a submersible slurry pump placed in a sump will quickly pump out the clear water above the settled solids, then lose suction. The agitator stirs the solids into a fluid mixture, making them pumpable.
Selecting agitator type:
Paddle agitator – Simple, low cost, good for light settled solids.
Vortex agitator – Creates downward eddy, lifts solids from bottom.
Jet agitator – Very effective, but requires additional piping and flow (some flow is recirculated from discharge).
Most medium and large submersible slurry pumps include a built‑in notched disc or blade agitator.
| Industry | Application | Typical Pump Size | Material |
|---|---|---|---|
| Mining – open pit | Dewatering, tailings transfer, sump cleaning | 30‑200 kW, 6″‑10″ | High‑chrome |
| Mining – underground | Slurry from stopes, mine water | 15‑90 kW, 4″‑8″ | High‑chrome |
| Dredging | River, harbour, pond cleaning | 50‑315 kW, 8″‑12″ | High‑chrome or rubber lined |
| Sand & gravel extraction | Pumping sand from pits, washing plant waste | 30‑110 kW, 6″‑8″ | High‑chrome |
| Mineral processing | Tailings lines, concentrate transfer, mill discharge | 15‑200 kW | Rubber lined (corrosive) |
| Power plant | Ash handling (fly ash, bottom ash) | 30‑110 kW | High‑chrome |
| Industrial | Ceramic slurry, paint waste, abrasive chemical slurries | 5‑30 kW | Stainless steel or rubber |
| Construction (piling, caissons) | Bentonite slurry, excavated mud | 10‑30 kW | High‑chrome |
Abrasion‑resistant hydraulics – High‑chrome Cr27‑Cr30 impeller and wear plate (550‑650 BHN).
Open impeller design – Handles large solids, easy to replace wear parts.
Built‑in agitator – Prevents solids settling, enables pumping of settled tailings.
Dual silicon carbide or tungsten carbide seals – Long life in abrasive service.
Oil chamber with moisture sensor – Early warning of seal failure.
IP68 motor – Fully submersible, thermal sensors, class F/H insulation.
Low speed (980‑1,450 rpm) – Reduces wear rate and extends pump life.
High voltage option – For long cable runs, reduces cable size and voltage drop.
Rubber lined option – For corrosive slurries (acidic or alkaline).
ATEX certified – For explosion‑proof underground mining.
Wear monitoring – Optional instrumentation to track wear ring clearance.
Hydrostatic test – Casing tested at 1.5x max submersion pressure.
Performance test – Slurry pump performance curve using water per ISO 9906.
Mechanical run test – Minimum 2 hours, vibration and temperature monitored.
Seal chamber test – Pressure test before assembly.
Material certification – EN 10204 3.1 for high‑chrome and rubber grades.
Submerged installation (wet sump):
Pump is suspended by chain or guide rail.
Must be fully submerged before start.
Ensure minimum submersion to avoid vortexing.
For sump cleaning, install pump at lowest point; agitator will stir settled solids.
Operation notes:
Start pump against a partially open discharge valve to reduce starting torque (for larger pumps).
Avoid dry running – even with thermal protection, seal life is shortened.
Monitor current: an increase over time indicates wear ring or impeller erosion; a decrease indicates clogging or cavitation.
After pumping abrasive solids, flush pump with clean water to remove abrasive particles.
| Task | Frequency |
|---|---|
| Inspect cable and connectors | Monthly |
| Check oil chamber for water (through screw plug) | 500 hours or each time pump is pulled |
| Replace mechanical seals | When moisture alarm occurs or at major overhaul (8,000‑10,000 hours) |
| Replace impeller and wear plate | When head drops >15% or current drops significantly |
| Check agitator for wear | Same as impeller |
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump does not start | No power, thermal trip, moisture alarm (locked out) | Check supply; reset thermal; investigate moisture |
| Low flow / head | Worn impeller or wear plate, partial blockage, low voltage | Replace wear parts; clean pump; check supply |
| Excessive vibration | Impeller imbalance, worn bearings, agitator damaged | Inspect and replace worn parts |
| Moisture alarm | Mechanical seal leaking | Replace seals and oil immediately |
| Pump trips on thermal overload | Run dry, high slurry density, voltage imbalance | Ensure submersion; dilute slurry; check supply |
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit (lower + upper) | 1 set |
| Impeller (open vane) | 1 |
| Wear plate / suction plate | 1 |
| Agitator blade / disc | 1 |
| Oil chamber gasket / O‑ring set | 1 set |
| Moisture sensor probe | 1 |
Engineered for maximum wear life – High‑chrome Cr27‑Cr30 as standard; tungsten carbide option.
Proven in mining – Thousands of units operating in abrasive tailings and sand.
Agitator standard – No need for separate jet ring or external flushing.
Low speed option – Reduces wear, extends time between overhauls.
High voltage capability – Direct connection to 3.3kV or 6.6kV mine power.
Global support – Spare parts and field service available worldwide.
Competitive lifecycle cost – Lower maintenance and longer wear life than standard pumps.
For detailed selection of the correct submersible slurry pump – including slurry density, particle size, pH, required flow and head, installation depth, and power supply – please contact our engineering team.
Email: info@hyrig.com
Our engineers support mining, dredging, and industrial slurry projects worldwide with reliable, abrasion‑resistant submersible slurry pumps – built for the toughest solids and longest service life.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.