Sulzer MSD Boiler Feed Pump – API 610 BB3 Axially Split Multistage Pump

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Sulzer MSD axially split multistage centrifugal pump for boiler feed water and feed water booster service in thermal and nuclear power plants. Flow to 3,200 m³/h, head to 2,900 m, pressure to 300 bar, temperature to 205°C. API 610 BB3 design with opposed impellers, axially split casing, double suction first stage. Over 10,000 units installed globally. Available in carbon steel, 316L, and duplex stainless steel. API 682 seals.

Conatct For Details
DetailReview(0)Additional

The Sulzer MSD is an API 610 (ISO 13709) Type BB3 horizontal, axially split, between‑bearings, multistage centrifugal pump. It is designed for the most demanding high pressure, high temperature applications where maximum reliability and efficiency are required. For boiler feed water (BFW) service, the MSD is the industry standard, delivering the high differential head characteristic of feed water pumps in thermal power plants, combined cycle plants, and industrial boiler systems.

Boiler Feed Water Service

Feed water pumps (FWP) pump the feed water from the deaerator through the HP heaters to the boiler or heat recovery steam generator (HRSG). The major characteristic of FWP is their high differential head. The MSD handles clean, deaerated water at elevated temperature (typically 120–160°C) and high pressure (up to 300 bar). In thermal power plants and nuclear safety-related services, the MSD provides continuous, reliable operation with high efficiency and long mean time between failures (MTBF). Over 10,000 MSD pumps are installed in product pipelines, boiler feed, water injection and even nuclear safety-related services around the globe.

Key Parameters

  • Capacities: Up to 3,200 m³/h / 14,000 US gpm

  • Total head: Up to 2,900 m / 9,500 ft

  • Design pressure: Up to 300 bar / 4,400 psi

  • Operating temperature: Up to 205°C / 400°F (typical BFW 120‑160°C)

  • Discharge sizes: 150 to 350 mm / 3 to 14 inches

  • Max speed: Up to 6,000 rpm

  • Flange ratings: 600#, 900#, and 1500# to suit project BFW pressure requirements

Design Features for Boiler Feed Water

FeatureBenefit
Axially split casingFull rotor access by lifting the upper casing half without disturbing suction/discharge piping – minimises maintenance downtime in power plant operations.
Opposed impeller arrangementBack‑to‑back impellers provide inherent axial thrust balance over the entire operating range, saving lube system costs and eliminating complex balance drums.
Double suction first‑stage impeller (available on most sizes)Significantly reduces Net Positive Suction Head Required (NPSHr) – critical for boiler feed pumps operating with limited suction head from deaerators.
Between‑bearings constructionRigid shaft supported by bearings at both ends ensures stability, minimal deflection, and smooth operation under full load conditions.
Double volute designBalances radial hydraulic forces, reducing shaft deflection and bearing loads.
Standard and high pressure casingsMultiple flange options (600#, 900#, 1500#) to meet boiler feed system pressure requirements.
API 682 seal chamberAccommodates single, tandem (Plan 52), or double (Plan 53B) cartridge mechanical seals for zero leakage of high pressure, high temperature BFW.
Renewable wear partsCasing rings, impeller rings, and interstage bushings are field‑replaceable, restoring efficiency without replacing major castings.
Heavy duty bearingsOil‑lubricated sleeve or tilting pad bearings for high speed, high power applications; water‑cooled bearing housings optional for elevated temperatures.
Optional centerline supportAvailable for high‑temperature stability when pumping BFW above 150°C.

Materials of Construction

ComponentStandard BFW ServiceUpgrade Option (Corrosive / High Purity)
CasingCarbon steel304SS / 316L / Duplex
Impellers12% Cr steel304SS / 316L / Duplex
ShaftAISI 4140 (chrome steel)17-4PH / Duplex
Wear rings / BushingsHardened 12% Cr with StelliteSilicon carbide / Tungsten carbide
BoltingA193 B7A193 B8M (316SS)
Gaskets / O‑ringsSpiral wound (SS/Graphite)PTFE / FFKM

API 682 Seal & Flush Plans

Boiler Feed Water ConditionRecommended Seal ConfigurationFlush Plan
Deaerated BFW, <120°CSingle mechanical sealPlan 11 (internal recirculation)
BFW >120°C, elevated temperatureSingle seal with coolerPlan 21 or Plan 23 (cooled recirculation)
Zero‑leak requirement (environmental compliance)Tandem sealPlan 52 (unpressurized buffer fluid)
High pressure BFW, critical serviceDouble mechanical seal (pressurized)Plan 53B

Auxiliary Systems

SystemRequirement for Boiler Feed Service
Minimum flow protectionAutomatic recirculation valve (ARC) or control valve + orifice – essential for boiler feed pumps to prevent overheating below minimum flow.
Bearing cooling waterWater‑cooled bearing housings recommended for BFW >120°C.
Casing drainsLow point drains with isolation valves for safe maintenance and inspection.
BaseplateHeavy duty fabricated steel baseplate, epoxy grouted, designed to 2× API 610 nozzle loads.
Lube oil systemForced oil circulation (required for high power / high speed units); oil ring self‑lubricating for moderate duties.
CouplingFlexible spacer coupling with removable guard – all necessary driver adapters available

Monitoring Systems (API 670)

Monitoring SystemSpecification
Bearing temperatureRTD probes (PT100) in drive‑end and non‑drive‑end housings, 4‑20 mA to DCS, alarm at 85°C, trip at 95°C.
Vibration monitoringProximity probes (eddy current) for shaft radial vibration; accelerometers for bearing housing velocity (optional).
Suction pressurePressure gauge with 4‑20 mA transmitter – low suction pressure interlock to protect against NPSH violation.
Discharge pressurePressure transmitter with high limit alarm to DCS.
Process temperatureThermowell‑mounted temperature transmitter on suction and discharge nozzles.
Flow monitoringFlow transmitter with low flow alarm – critical for boiler feed pump minimum flow protection.

Applications

  • Boiler feed water for coal‑fired and oil‑fired power plants

  • Feed water for gas‑fired combined cycle plants (HRSG feed)

  • Biomass waste fired power plant boiler feed

  • Nuclear power plant safety‑related BFW and auxiliary services

  • Industrial boiler feed (steam generation for manufacturing)

  • High pressure water injection in oil and gas fields

  • High‑head mine dewatering

  • Refinery hydrocarbon processing boiler feed

API 610 Material Classes Available

  • S‑1 to S‑8 – austenitic stainless steels

  • C‑6 – duplex stainless steel

  • D‑1 / D‑2 – higher alloys

  • NACE MR0175 / MR0103 compliance for sour service when required

Design and Operating Benefits

  • Full API 610 (ISO 13709) Type BB3 compliance – highest industry standard for heavy duty multistage pumps

  • Broadest hydraulic coverage of any BB3 multistage pump in the market for precise FWP selection

  • Over 10,000 MSD pumps installed globally – proven reliability in boiler feed and nuclear services

  • Design life of 20 years per API 610 – suitable for long‑term power plant operation

  • High efficiency (low energy consumption) and improved seal technology

  • Variable frequency drive (VFD) ready – allows flexible performance and improved energy efficiency

  • 600#, 900#, and 1500# flange ratings to suit all FWP differential head requirements

  • Sulzer provides FEED assistance, rerates to optimize performance and lower power costs

  • Comprehensive training and professional service enable customers to operate the pump more reliably

  • Retrofit service to re-establish BEP if operating conditions change

Why Sulzer MSD for Boiler Feed Water?

  • Unparalleled BB3 hydraulic coverage – the original and still industry standard for boiler feed pumps

  • Full API 610 compliance – engineered for the most demanding high-pressure, high‑temperature BFW services

  • Over 10,000 units installed globally – field proven in nuclear power, thermal power, and industrial boiler systems

  • Axially split casing – fastest maintenance access without disturbing piping

  • Opposed impeller axial thrust balance – reduces lube system complexity and cost

  • Double suction first stage – minimizes NPSH requirement for deaerator suction conditions

  • High pressure casings – 1500# flange rating available for supercritical and ultra‑supercritical boiler feed applications

  • Broad material selection – carbon steel, 304SS, 316L, duplex, and high alloys available

  • Sulzer local support in China – manufacturing and service facilities in Dalian, Suzhou, and Kunshan

Sourcing & Support in China

We supply Sulzer MSD pumps to power plants, industrial facilities, and nuclear projects throughout China. Our team provides pump selection assistance, complete documentation (performance curves, GA drawings, API datasheets, material certifications), and after‑sales support. Spare parts, including wear rings, bushings, seals, and bearings, are available through our local supply network. Sulzer also provides retrofit service to re‑establish the best efficiency point if operating conditions change.

For more information or a custom proposal for your boiler feed pump (Sulzer MSD) application, contact us at info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code