The Sulzer MSD is an API 610 (ISO 13709) Type BB3 horizontal, axially split, between‑bearings, multistage centrifugal pump. It is designed for the most demanding high pressure, high temperature applications where maximum reliability and efficiency are required. For boiler feed water (BFW) service, the MSD is the industry standard, delivering the high differential head characteristic of feed water pumps in thermal power plants, combined cycle plants, and industrial boiler systems.
Boiler Feed Water Service
Feed water pumps (FWP) pump the feed water from the deaerator through the HP heaters to the boiler or heat recovery steam generator (HRSG). The major characteristic of FWP is their high differential head. The MSD handles clean, deaerated water at elevated temperature (typically 120–160°C) and high pressure (up to 300 bar). In thermal power plants and nuclear safety-related services, the MSD provides continuous, reliable operation with high efficiency and long mean time between failures (MTBF). Over 10,000 MSD pumps are installed in product pipelines, boiler feed, water injection and even nuclear safety-related services around the globe.
Key Parameters
Capacities: Up to 3,200 m³/h / 14,000 US gpm
Total head: Up to 2,900 m / 9,500 ft
Design pressure: Up to 300 bar / 4,400 psi
Operating temperature: Up to 205°C / 400°F (typical BFW 120‑160°C)
Discharge sizes: 150 to 350 mm / 3 to 14 inches
Max speed: Up to 6,000 rpm
Flange ratings: 600#, 900#, and 1500# to suit project BFW pressure requirements
Design Features for Boiler Feed Water
| Feature | Benefit |
|---|---|
| Axially split casing | Full rotor access by lifting the upper casing half without disturbing suction/discharge piping – minimises maintenance downtime in power plant operations. |
| Opposed impeller arrangement | Back‑to‑back impellers provide inherent axial thrust balance over the entire operating range, saving lube system costs and eliminating complex balance drums. |
| Double suction first‑stage impeller (available on most sizes) | Significantly reduces Net Positive Suction Head Required (NPSHr) – critical for boiler feed pumps operating with limited suction head from deaerators. |
| Between‑bearings construction | Rigid shaft supported by bearings at both ends ensures stability, minimal deflection, and smooth operation under full load conditions. |
| Double volute design | Balances radial hydraulic forces, reducing shaft deflection and bearing loads. |
| Standard and high pressure casings | Multiple flange options (600#, 900#, 1500#) to meet boiler feed system pressure requirements. |
| API 682 seal chamber | Accommodates single, tandem (Plan 52), or double (Plan 53B) cartridge mechanical seals for zero leakage of high pressure, high temperature BFW. |
| Renewable wear parts | Casing rings, impeller rings, and interstage bushings are field‑replaceable, restoring efficiency without replacing major castings. |
| Heavy duty bearings | Oil‑lubricated sleeve or tilting pad bearings for high speed, high power applications; water‑cooled bearing housings optional for elevated temperatures. |
| Optional centerline support | Available for high‑temperature stability when pumping BFW above 150°C. |
Materials of Construction
| Component | Standard BFW Service | Upgrade Option (Corrosive / High Purity) |
|---|---|---|
| Casing | Carbon steel | 304SS / 316L / Duplex |
| Impellers | 12% Cr steel | 304SS / 316L / Duplex |
| Shaft | AISI 4140 (chrome steel) | 17-4PH / Duplex |
| Wear rings / Bushings | Hardened 12% Cr with Stellite | Silicon carbide / Tungsten carbide |
| Bolting | A193 B7 | A193 B8M (316SS) |
| Gaskets / O‑rings | Spiral wound (SS/Graphite) | PTFE / FFKM |
API 682 Seal & Flush Plans
| Boiler Feed Water Condition | Recommended Seal Configuration | Flush Plan |
|---|---|---|
| Deaerated BFW, <120°C | Single mechanical seal | Plan 11 (internal recirculation) |
| BFW >120°C, elevated temperature | Single seal with cooler | Plan 21 or Plan 23 (cooled recirculation) |
| Zero‑leak requirement (environmental compliance) | Tandem seal | Plan 52 (unpressurized buffer fluid) |
| High pressure BFW, critical service | Double mechanical seal (pressurized) | Plan 53B |
Auxiliary Systems
| System | Requirement for Boiler Feed Service |
|---|---|
| Minimum flow protection | Automatic recirculation valve (ARC) or control valve + orifice – essential for boiler feed pumps to prevent overheating below minimum flow. |
| Bearing cooling water | Water‑cooled bearing housings recommended for BFW >120°C. |
| Casing drains | Low point drains with isolation valves for safe maintenance and inspection. |
| Baseplate | Heavy duty fabricated steel baseplate, epoxy grouted, designed to 2× API 610 nozzle loads. |
| Lube oil system | Forced oil circulation (required for high power / high speed units); oil ring self‑lubricating for moderate duties. |
| Coupling | Flexible spacer coupling with removable guard – all necessary driver adapters available |
Monitoring Systems (API 670)
| Monitoring System | Specification |
|---|---|
| Bearing temperature | RTD probes (PT100) in drive‑end and non‑drive‑end housings, 4‑20 mA to DCS, alarm at 85°C, trip at 95°C. |
| Vibration monitoring | Proximity probes (eddy current) for shaft radial vibration; accelerometers for bearing housing velocity (optional). |
| Suction pressure | Pressure gauge with 4‑20 mA transmitter – low suction pressure interlock to protect against NPSH violation. |
| Discharge pressure | Pressure transmitter with high limit alarm to DCS. |
| Process temperature | Thermowell‑mounted temperature transmitter on suction and discharge nozzles. |
| Flow monitoring | Flow transmitter with low flow alarm – critical for boiler feed pump minimum flow protection. |
Applications
Boiler feed water for coal‑fired and oil‑fired power plants
Feed water for gas‑fired combined cycle plants (HRSG feed)
Biomass waste fired power plant boiler feed
Nuclear power plant safety‑related BFW and auxiliary services
Industrial boiler feed (steam generation for manufacturing)
High pressure water injection in oil and gas fields
High‑head mine dewatering
Refinery hydrocarbon processing boiler feed
API 610 Material Classes Available
S‑1 to S‑8 – austenitic stainless steels
C‑6 – duplex stainless steel
D‑1 / D‑2 – higher alloys
NACE MR0175 / MR0103 compliance for sour service when required
Design and Operating Benefits
Full API 610 (ISO 13709) Type BB3 compliance – highest industry standard for heavy duty multistage pumps
Broadest hydraulic coverage of any BB3 multistage pump in the market for precise FWP selection
Over 10,000 MSD pumps installed globally – proven reliability in boiler feed and nuclear services
Design life of 20 years per API 610 – suitable for long‑term power plant operation
High efficiency (low energy consumption) and improved seal technology
Variable frequency drive (VFD) ready – allows flexible performance and improved energy efficiency
600#, 900#, and 1500# flange ratings to suit all FWP differential head requirements
Sulzer provides FEED assistance, rerates to optimize performance and lower power costs
Comprehensive training and professional service enable customers to operate the pump more reliably
Retrofit service to re-establish BEP if operating conditions change
Why Sulzer MSD for Boiler Feed Water?
Unparalleled BB3 hydraulic coverage – the original and still industry standard for boiler feed pumps
Full API 610 compliance – engineered for the most demanding high-pressure, high‑temperature BFW services
Over 10,000 units installed globally – field proven in nuclear power, thermal power, and industrial boiler systems
Axially split casing – fastest maintenance access without disturbing piping
Opposed impeller axial thrust balance – reduces lube system complexity and cost
Double suction first stage – minimizes NPSH requirement for deaerator suction conditions
High pressure casings – 1500# flange rating available for supercritical and ultra‑supercritical boiler feed applications
Broad material selection – carbon steel, 304SS, 316L, duplex, and high alloys available
Sulzer local support in China – manufacturing and service facilities in Dalian, Suzhou, and Kunshan
Sourcing & Support in China
We supply Sulzer MSD pumps to power plants, industrial facilities, and nuclear projects throughout China. Our team provides pump selection assistance, complete documentation (performance curves, GA drawings, API datasheets, material certifications), and after‑sales support. Spare parts, including wear rings, bushings, seals, and bearings, are available through our local supply network. Sulzer also provides retrofit service to re‑establish the best efficiency point if operating conditions change.
For more information or a custom proposal for your boiler feed pump (Sulzer MSD) application, contact us at info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.