The Sulzer MSD is an API 610 (ISO 13709) Type BB3 horizontal, axially split, between‑bearings, multistage centrifugal pump. It is engineered for demanding high pressure, high temperature services requiring maximum reliability and maintainability. For rich solution circulation in hot potassium carbonate CO2 absorption systems, the MSD provides optimal hydraulic performance and corrosion resistance.
Rich Solution Service Overview
In the hot potassium carbonate process (Benfield, Vetrocoke, or other activated carbonate systems), rich solution – potassium carbonate (K₂CO₃) that has absorbed CO₂ in the absorber tower, forming potassium bicarbonate (KHCO₃) – is pumped from the absorber bottom to the regenerator (stripper/desorber) to release CO₂ and regenerate the lean solution. The rich solution pump operates at typically 70–120°C (regenerator feed) and pressures up to 70–100 bar. The fluid is mildly corrosive, has higher CO₂ loading compared to lean solution, and may contain trace solid precipitates (bicarbonate crystals if temperature fluctuates).
Why MSD for Rich Solution?
Proven BB3 axially split design – over 10,000 MSD pumps installed globally in demanding services, including nuclear, ensuring exceptional reliability.
Full API 610 compliance – manufactured and tested to the most stringent international standard for heavy duty process pumps.
Opposed impeller arrangement – provides inherent axial thrust self‑balancing, eliminating complex balance drums/disks and reducing lube oil system cost.
Axially split casing – allows full rotor access without disconnecting piping, critical for rich solution pumps where maintenance must be fast and safe.
Double suction first stage – improves low NPSH performance when the absorber bottom NPSHa is limited.
Material flexibility – 316L, duplex, super duplex, and higher alloys available to match rich solution corrosivity (which may be slightly higher than lean solution due to CO₂‑carbonic acid formation).
Key Parameters
Capacities: Up to 3,200 m³/h (covers typical rich solution circulation)
Total head: Up to 2,900 m / 9,500 ft (far exceeding rich loop requirements)
Operating pressure: Up to 300 bar / 4,400 psi (covers typical 70‑100 bar)
Operating temperature: Up to +205°C (covers rich solution 70‑120°C)
Discharge sizes: 150 to 350 mm / 6 to 14 inches
Max speed: Up to 6,000 rpm
Flange ratings: 600#, 900#, 1500# to suit project requirements
Design Features for Rich Solution
| Feature | Benefit |
|---|---|
| Axially split casing | Horizontally split along centerline; top half lifts off for full rotor access without disconnecting suction/discharge piping – minimises maintenance downtime. |
| Opposed impeller arrangement | Back‑to‑back impellers provide inherent axial thrust self‑balancing, eliminating balance drum/disk and reducing lube system complexity. |
| Double suction first‑stage impeller (available on most sizes) | Reduces Net Positive Suction Head Required (NPSHr) – critical for rich solution pumps drawing from absorber bottoms with limited submergence. |
| Between‑bearings construction | Rigid shaft supported by bearings at both ends ensures exceptional stability, minimal deflection, and smooth operation under varying loads. |
| Renewable wear parts | Casing rings, impeller rings, and interstage bushings are field‑replaceable, restoring pump efficiency without replacing major castings. |
| API 682 seal chamber | Fully compliant with API 682 4th Edition, accommodating single, tandem (Plan 52/53A), and double (Plan 53B) cartridge mechanical seals. |
| Heavy duty bearings | Angular contact thrust bearings and cylindrical roller radial bearings; oil ring self‑lubricating (standard) or forced oil circulation (high power). Water‑cooled housings available – recommended for rich solution above 100°C. |
| Bearing housing cooling | Water‑cooled housings maintain bearing temperature ≤70°C when pumping hot carbonate at 120°C, extending bearing life. |
Materials for Rich Solution (CO₂-Loaded Potassium Carbonate)
While rich solution is typically slightly more corrosive than lean solution due to dissolved CO₂ (forming weak carbonic acid), and may have lower pH, material selection must account for this. The following matrix provides recommendations:
| Service Condition | Recommended Material (Wetted Parts) |
|---|---|
| Clean rich potassium carbonate solution, CO₂‑loaded, up to 120°C, neutral pH | 316L stainless steel (minimum) |
| Rich solution with trace chlorides or lower pH (carbonic acid effect) | Duplex 2205 or super duplex 2507 |
| Rich solution containing activators (amines, promoters) or potential for bicarbonate crystallization | Duplex 2205 |
| Aggressive service with H₂S or high chloride carryover | Super duplex 25% Cr minimum (e.g., SAF 2507, UNS S32760) |
Material recommendations by component (rich solution service, typical):
| Component | Standard (Clean Rich Carbonate) | Upgrade (Corrosive / High Temp / Impurities) |
|---|---|---|
| Casing (inner) | 316L stainless steel | Duplex 2205 / Super duplex 25% Cr |
| Impellers | 316L stainless steel | Duplex 2205 / Super duplex |
| Shaft | 17-4PH stainless steel | Duplex / Super duplex |
| Wear rings (casing/impeller) | 316L with Stellite hard facing | Duplex with Stellite / Silicon carbide |
| Interstage bushings | Silicon carbide or bronze | Tungsten carbide |
| Casing bolting | A193 B8M Class 2 (316 SS) | Duplex / Super duplex |
| Gaskets / O‑rings | PTFE or EPDM | FFKM (Kalrez) for aggressive conditions |
Note: Carbon steel is NOT acceptable for hot carbonate service (rich or lean) above 80°C. 316L is the minimum; duplex or super duplex provides additional corrosion resistance and strength, particularly important if the rich solution pH drops below 9.
Flush Plan & Seal Selection
For rich solution (moderately corrosive, not acutely toxic but environmentally sensitive), the following seal arrangements are typically used:
| Service | Recommended Seal Configuration | Flush Plan |
|---|---|---|
| Rich carbonate solution, clean, <100°C | Single mechanical seal | Plan 11 (internal recirculation with orifice) |
| Rich carbonate solution, >100°C | Single seal with cooler | Plan 21 or Plan 23 (cooled recirculation) |
| Zero‑leak or fugitive emission control | Tandem mechanical seal | Plan 52 (unpressurized buffer fluid reservoir) |
| Highly corrosive or hazardous (e.g., with H₂S) | Double mechanical seal (pressurized) | Plan 53B |
Seal faces: Silicon carbide vs. carbon (standard). For dirty or scaling service (risk of bicarbonate crystals), tungsten carbide vs. carbon.
Secondary seals: EPDM or PTFE (compatible with hot carbonate). If aggressive chemicals present, upgrade to FFKM.
Auxiliary Systems
| System | Requirement for Rich Solution Service |
|---|---|
| Minimum flow protection | Automatic recirculation valve (ARC) or control valve + orifice – ensures pump stays above minimum continuous stable flow, preventing overheating and cavitation. |
| Bearing cooling water | Water‑cooled bearing housings recommended for rich solution >100°C. |
| Casing drains | Low point drains with isolation valves for safe cleaning and maintenance – important for removing any bicarbonate deposits before disassembly. |
| Flushing connections | Connections on casing and seal chamber for washing before maintenance (warm water to dissolve any carbonate crystals). |
| Baseplate | Heavy duty fabricated steel baseplate, epoxy grouted, designed to 2× API 610 nozzle load requirements. |
Monitoring Systems (API 670 Recommendations)
| Monitoring System | Specification |
|---|---|
| Bearing temperature | RTD probes (PT100) in drive‑end and non‑drive‑end housings, 4‑20 mA to DCS, alarm at 85°C, trip at 95°C. |
| Vibration monitoring | Proximity probes (eddy current) for shaft radial vibration (recommended for critical pumps); accelerometers for bearing housing velocity (optional). |
| Suction pressure | Pressure gauge with 4‑20 mA transmitter – low suction pressure alarm to protect against NPSH violation. |
| Discharge pressure | Pressure transmitter with high limit alarm to DCS. |
| Process temperature | Thermowell‑mounted temperature transmitter on suction and discharge nozzles – critical for ensuring rich solution remains above crystallization point (typically >70°C) to prevent bicarbonate solids from forming. |
Applications
The Sulzer MSD rich solution pump is suitable for:
Benfield CO₂ removal units: Rich carbonate solution circulation from absorber to regenerator.
Vetrocoke process: Similar hot carbonate rich solution service.
Other activated hot carbonate systems: Including those using amines or other promoters.
Green ammonia rich solution service: Circulation in CO2 capture loops for renewable hydrogen-based ammonia synthesis.
Amine rich solution circulation (MEA, DEA, MDEA): For gas sweetening (with appropriate materials, typically 316L or duplex).
Why Sulzer MSD for Rich Solution?
Proven BB3 axially split design with over 10,000 units installed globally in demanding services.
Full API 610 compliance – designed and manufactured to the most stringent international standard for heavy duty process pumps.
Opposed impeller thrust balancing – eliminates complex balance drums/disks, reducing lube system cost and improving reliability.
Axially split casing – full rotor access without removing piping, critical for rich solution pumps where maintenance must occur during tight plant turnarounds.
Double suction first stage – improves low NPSH performance when the absorber bottom provides limited submergence.
Material flexibility – 316L, duplex, super duplex, high alloys, NACE compliance available to match rich solution corrosivity.
API 682 seal compatibility – Plan 21/23 for hot carbonate; Plan 52/53B for zero emissions.
Local support in China – Sulzer manufacturing and service facilities in Dalian, Suzhou, and Kunshan provide local supply, spare parts, and after‑sales support for MSD pumps.
For more information or a custom proposal for your rich solution pump (Sulzer MSD) application, contact us at info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.