HYRIG's Oil Seal (Part No. 2200-200400) is a precision-engineered replacement component exclusively designed for Sulzer BBS 200-400 double suction centrifugal pumps, fully complying with API 610 (12th Edition) and ISO 6194 standards. As a critical sealing element for the bearing housing, this oil seal prevents lubricant leakage and blocks external contaminants (dust, moisture, media particles) from entering the bearing assembly—directly replicating Sulzer's original design dimensions, lip structure, and sealing performance at a cost-effective price point.
Crafted for demanding industrial environments (chemical processing, petroleum refining, power generation, and water treatment), the oil seal features a robust skeleton structure, optimized lip design, and high-quality sealing material to withstand rotational friction, temperature fluctuations, and lubricant compatibility challenges. Each unit undergoes strict dimensional inspection and leakage testing to ensure seamless integration with Sulzer BBS 200-400 bearing housings, 1211-200400 bearing-side shaft sleeves, and 2000-200400 angular contact bearing sets, extending bearing service life and maintaining pump operational reliability.
| Item | Details |
|---|---|
| Part Number | 2200-200400 |
| Compatible Pump Model | Sulzer BBS 200-400 (API 610 Centrifugal Pump) |
| Compatible Components | 1211-200400 Shaft Sleeve (Bearing Side), 2000-200400 Angular Contact Bearing Set (HYRIG/Sulzer Original) |
| Design Standard | API 610 (12th Edition), ISO 6194, DIN 3760 |
| Seal Type | Single-lip / Double-lip with spring (per Sulzer original design) |
| Installation Position | Bearing housing output/input end (seals between shaft sleeve and housing) |
| Dimensional Tolerance | Complies with ISO 3320 and DIN 3760 standards |
| Inner Diameter (ID) | Matches 1211-200400 shaft sleeve outer diameter (precision fit) |
| Outer Diameter (OD) | Matches Sulzer BBS 200-400 bearing housing bore diameter |
| Width (W) | Optimized for bearing housing spacing (prevents interference with bearing) |
| Lip Design | Single lip (standard) / Double lip (enhanced contamination protection, optional) |
| Spring Type | Stainless steel garter spring (ensures constant lip contact pressure) |
Select the optimal combination of seal lip, skeleton, and auxiliary materials based on lubricant type, operating temperature, and environmental conditions—all options ensure reliable sealing and compatibility with pump components:
| Lip Material | Skeleton Material | Operating Temperature Range | Key Properties | Recommended Applications |
|---|---|---|---|---|
| NBR (Nitrile Rubber) | Carbon Steel | -30°C to 100°C (-22°F to 212°F) | Excellent oil resistance, good tensile strength, cost-effective | Mineral oil lubrication, general industrial applications, standard temperature conditions |
| FKM (Viton® Fluoroelastomer) | Stainless Steel | -15°C to 200°C (5°F to 392°F) | Superior chemical/lubricant resistance, high-temperature stability | Synthetic oil, high-temperature fluids, aggressive industrial environments |
| PU (Polyurethane) | Carbon Steel/Stainless Steel | -20°C to 120°C (-4°F to 248°F) | High wear resistance, good mechanical strength, low friction | High-speed operation, heavy-duty load, extended service intervals |
| EPDM (Ethylene-Propylene) | Carbon Steel | -40°C to 120°C (-40°F to 248°F) | Outstanding weather/ozone resistance, compatibility with polar lubricants | Water-glycol lubricants, HVAC fluids, outdoor installations |
| Silicone Rubber (VMQ) | Stainless Steel | -60°C to 180°C (-76°F to 356°F) | Extreme low-temperature flexibility, high-temperature stability | Cryogenic applications, high-temperature steam, thermal cycling conditions |
Material certification available upon request (including chemical compatibility reports and temperature resistance test data).
Visible lubricant leakage from the bearing housing (drips or oil film on exterior)
Seal lip damage (cracks, hardening, swelling, or deformation)
Contamination in bearing lubricant (moisture, dust, or metal particles)
Bearing overheating related to seal friction (abnormal temperature rise)
During bearing or shaft sleeve replacement (recommended to replace seal synchronously)
Proactive replacement: Every 1-2 years (or 5,000-8,000 operating hours) for critical applications
Verify part number, lip type, and dimensions match Sulzer BBS 200-400 requirements.
Check for transportation damage (lip scratches, skeleton deformation) and ensure the seal is intact.
Confirm compatibility with lubricant type (reference material compatibility table).
Clean the bearing housing bore and 1211-200400 shaft sleeve surface (remove rust, debris, or old seal residue).
Apply a thin layer of compatible lubricant to the seal lip and inner diameter (reduces initial friction and prevents lip damage).
Use a seal installation tool or sleeve (to avoid lip distortion) to press the seal into the bearing housing bore—ensure the lip faces the lubricant side (inner bearing chamber).
Press the seal until fully seated against the housing shoulder (no gaps or misalignment).
For double-lip seals: Fill the space between lips with lubricant or grease to enhance contamination protection.
Avoid using sharp tools or brute force during installation (prevents skeleton bending or lip tearing).
Perform a static rotation test to confirm no seal lip damage or binding.
Run the pump at idle speed for 10-15 minutes, then inspect for lubricant leakage.
Monitor bearing temperature and seal area for abnormal heating (temperature rise should not exceed 15°C above ambient).
Check seal integrity after first week of operation; replace immediately if leakage is detected.
Precision Sealing Fit: CNC-machined to match Sulzer BBS 200-400's bearing housing and 1211-200400 shaft sleeve dimensions—no modifications required.
Dual Protection Design: Prevents lubricant leakage (preserves bearing lubrication) and blocks external contaminants (reduces bearing failure risk).
Lubricant & Temperature Compatible: Multiple material options tailored to different lubricants and operating temperatures, ensuring long-term reliability.
Seamless Integration: Perfectly pairs with 2000-200400 angular contact bearing set and 1211-200400 shaft sleeve for complete bearing assembly protection.
Quality Assurance: 12-month warranty against material defects and manufacturing errors; technical support for material selection and installation guidance.
For pricing, material options, lead time, or custom lip design requests (e.g., double-lip for harsh environments), contact HYRIG's technical sales team:
Email: info@hyrig.com
Please provide your pump's serial number, operating conditions (temperature, lubricant type, environmental contaminants), and bearing assembly configuration for personalized recommendations and a detailed quote.
Note: HYRIG's 2200-200400 oil seal is a drop-in alternative to Sulzer original parts, designed to meet or exceed API 610 and ISO 6194 performance and reliability standards. All units are packaged in protective materials to prevent lip damage during transit.