Tail Gas Absorber Bottom Pump – 22.3m Head & 21 m³/h Flow | API 610 OH2 Pump Product Description The Tail Gas Absorber Bottom Pump (also referred to as Off‑Gas Absorber Bottom Pump or Vent Gas Absorber Bottom Pump) is an API 610 OH2 single‑stage overhung centrifugal pump designed for absorber bott

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
The Tail Gas Absorber Bottom Pump (API 610 OH2) delivers 21 m³/h at 22.3m head for styrene vent gas absorber absorbent. Handles 982 kg/m³ density at 16.2°C with 0.17 MPaG suction / 0.38 MPaG discharge. NPSHa 12.0m ensures trouble‑free operation. Ideal for tail gas, off‑gas, or vent gas absorber bottom duty. Hyrig provides drop‑in replacements for major brands – same performance, better cost, shorter delivery. Contact: info@hyrig.com
Conatct For Details
DetailReview(0)Additional

Tail Gas Absorber Bottom Pump – 22.3m Head & 21 m³/h Flow | API 610 OH2 Pump

Product Description

The Tail Gas Absorber Bottom Pump (also referred to as Off‑Gas Absorber Bottom Pump or Vent Gas Absorber Bottom Pump) is an API 610 OH2 single‑stage overhung centrifugal pump designed for absorber bottom service in styrene monomer production units. It delivers a head of 22.3 meters at a flow rate of 21 m³/h, handling absorbent with a density of 982 kg/m³ at 16.2°C.

Key operating parameters:

  • Flow rate: 21 m³/h

  • Head: 22.3 m

  • Medium: Absorbent

  • Density: 982 kg/m³

  • Temperature: 16.2 °C (inlet/outlet)

  • Suction pressure: 0.17 MPa G / Discharge pressure: 0.38 MPa G

  • NPSHa (effective suction height): 12.0 m – ample margin for reliable operation

  • Pump type: API 610 OH2

Engineered for tail gas absorber bottom drainage and circulation in styrene plants, this OH2 pump handles clean absorbent service with generous NPSHa. The back pull‑out design allows easy maintenance without disturbing piping, making it ideal for continuous bottom pump duty on vent gas absorbers.

Model variants available:

  • TGA‑BP (Tail Gas Absorber – Bottom Pump, concise and clear, recommended)

  • OGA‑BP (if the project uses Off‑Gas abbreviation)

  • TGA‑BTM‑P (BTM = Bottom, more explicit but slightly longer)

  • AB‑BP (AB = Absorber, but lacks "tail gas" specificity – not recommended alone)

Hyrig specializes in supplying API 610 standard process centrifugal pumps (OH2, BB2, BB5, VS6). Our core strength lies in providing complete drop‑in replacements for world‑leading brands such as Sulzer, Flowserve, and ITT Goulds – including Sulzer (OHH, OHHL, BBS, CD, CP, GSG, SJD‑API), Flowserve (HPX, HDX, HED‑DS, CSB, HDB, HSB, VCP, VCT), and Goulds (3700, 3700 LFI, 3640, 3620, 7200CB, VICR, VIC) pumps. All replacements deliver identical performance, quality, and standard compliance, with better cost‑effectiveness and shorter delivery times, offering efficient and economical fluid handling solutions for industrial applications.

For inquiries, please contact us at: info@hyrig.com