When performing artificial lift (ESP) operations, standard pipe rams cannot seal around electrical submersible pump cables. HYRIG manufactures specialized REDA cable packers for the 7 1/16" 5M Hydraulic Townsend BOP.
| Ram Size | Cable Size | Profile | Packer P/N |
|---|---|---|---|
| 2 3/8" | #6 Cable | Round | 2260002 |
| 2 3/8" | #6 Cable | Flat | 226000-1 |
| 2 3/8" | #4 Cable | Round | 226000-2 |
| 2 3/8" | #4 Cable | Flat | 226000-3 |
| 2 3/8" | #2 Cable | Round | 226000-4 |
| 2 3/8" | #2 Cable | Flat | 226000-5 |
| 2 7/8" | #6 Cable | Round | 226000-6 |
| 2 7/8" | #6 Cable | Flat | 226000-7 |
| 2 7/8" | #4 Cable | Round | 226000-8 |
| 2 7/8" | #4 Cable | Flat | 226000-9 |
| 2 7/8" | #2 Cable | Round | 226000-10 |
| 2 7/8" | #2 Cable | Flat | 226000-11 |
| Situation | Recommendation |
|---|---|
| You are running a flat ESP cable | Select the corresponding 'Flat' packer P/N. |
| You are running a round ESP cable | Select the corresponding 'Round' packer P/N. |
| Operating in extreme pressure differentials | Consider the High Crown Top Seal (224023HC) for enhanced containment. |
Common field error: Attempting to force a standard round packer around a flat ESP cable, resulting in severe rubber extrusion and loss of well control.
Email info@hyrig.com with:
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.