| Model | Nominal Size | Max Pressure | Max Flow | Solenoid Type | Mounting |
|---|---|---|---|---|---|
| WE10 20 Series | DN10 | 31.5 MPa | 100 L/min | Wet-armature | ISO 4401-05 |
| WE10 31 Series | DN10 | 31.5 MPa | 120 L/min | Replaceable Coil | ISO 4401-05 |
| WE6 61 Series | DN6 | 35 MPa | 80 L/min | Wet-armature | ISO 4401-03 |
Data source: Technical data table.
The WE10 20 valve uses a wet-armature solenoid to shift the spool. In standard versions, a spring returns the spool to the center. The O-type has no spring and no detent (requires continuous power), while the OF-type has a detent to hold the position without power. A plug-in damper can be installed in the P port to stabilize high flows.
Available in multiple spool types (A, B, C, D, E, G, H, J, L, M, P, Q, R, T, U, V, W, Y).
Options:
Used for directional control in plastic machinery, machine tools, metallurgy, and mining equipment.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure whether you need a standard, O-type, or OF-type valve? Explore related models: WE10 20 Valve or tell us your system requirements.
Q: What is the difference between the 20 series and 31 series?
A: The 31 series supports a slightly higher flow rate (120 L/min) and features a replaceable coil design (C type).
Q: What is the maximum flow for the WE10 20 valve?
A: The WE10 20 supports a maximum flow rate of 100 L/min.
Q: Do I need a plug-in damper?
A: A damper is recommended if your system flow approaches the maximum limit to prevent spool vibration.
For WE10 20 series solenoid directional valve selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.