| Model | Nominal Size | Max Pressure | Max Flow | Solenoid Type |
|---|---|---|---|---|
| WE10 20 | DN10 | 31.5 MPa | 100 L/min | Wet-armature |
| WE10 31 Valve | DN10 | 31.5 MPa | 120 L/min | Replaceable Coil |
| WE6 61 Valve | DN6 | 35 MPa | 80 L/min | Threaded Sleeve |
Data source: Technical data table.
Text-based mounting parameters for the WE10 20 valve:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-05 (CETOP 5) |
| Bolt Pattern | 4 x M6 threaded holes (54 x 54 mm) |
| Port Connections | A, B, P, T (Requires O-ring 12 x 2 mm) |
| Overall Length | 298 mm (Double solenoid, DC) |
| Body Width | 70 mm |
| Height | 119 mm (DC), 81.5 mm (AC) |
The WE10 20 uses a wet-armature solenoid. The standard version is spring-centered. The O-type has no spring and no detent, requiring continuous power to hold position. The OF-type includes a detent to mechanically hold the spool position without power. A plug-in damper (B08/B10/B12) can be inserted into the P port for high-flow stabilization.
Standard spool types: A, B, C, D, E, G, H, J, L, M, P, Q, R, T, U, V, W, Y.
Add-ons:
Replacing an old valve? Check:
Used for automated directional control in plastic machinery, metallurgy, mining, and general hydraulic systems.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help determining the spool type or damper requirement? Contact our engineers with your system specifications.
Q: What is the max flow rate for the WE10 20 valve?
A: The WE10 20 supports a maximum flow rate of 100 L/min.
Q: Does the WE10 20 come with a manual override?
A: Yes, standard models feature a manual push button for emergency operation.
Q: Can I order an OF-type (detent) version?
A: Yes, specify the OF code in your model string to get the detent mechanism.
Q: What O-ring size is required for the mounting surface?
A: The mounting interface uses O-rings sized 12 x 2 mm.
For WE10 20 solenoid valve selection and spare parts, contact HYRIG: info@hyrig.com