| Model | Nominal Size | Max Pressure | Max Flow | Pilot Type | Mounting |
|---|---|---|---|---|---|
| WH25 | DN25 | 35 MPa | 650 L/min | Hydraulic | ISO 4401-08 |
| WEH25 Valve | DN25 | 35 MPa | 650 L/min | Solenoid | ISO 4401-08 |
| WH16 Valve | DN16 | 35 MPa | 300 L/min | Hydraulic | ISO 4401-07 |
| WH32 Valve | DN32 | 35 MPa | 1100 L/min | Hydraulic | ISO 4401-10 |
Data source: Technical data table.
Text-based mounting parameters for the WH25:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-08 (CETOP 8) |
| Bolt Pattern | 6 x M12 threaded holes |
| Port Connections | A, B, P, T (Requires O-ring 27 x 3 mm) |
| Overall Length | Approx. 297 mm (Main valve) |
| Main Body Width | 117 mm |
The WH25 is controlled solely by external hydraulic pilot pressure. The main spool is shifted by the pressure applied to the control pistons. It uses a robust casting design to handle high flows up to 650 L/min.
Available in spool types (A, B, C, D, E, G, H, J, L, M, P, Q, R, T, U, V, W, Y).
Options:
Replacing an old valve? Check:
Used in heavy machinery, mining, and hydraulic logic systems in explosive atmospheres.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help identifying the correct control oil port connections? Contact our engineers with your system specifications.
Q: Does the WH25 require an electrical connection?
A: No, the WH25 is controlled purely by hydraulic pressure.
Q: What is the minimum pilot pressure for the WH25?
A: The minimum pilot pressure for internal supply is 1.3 MPa.
Q: Can I replace a WEH25 with a WH25?
A: Yes, the mounting interface is the same, but you must provide external pilot pressure lines for the WH25.
For WH25 hydraulic valve selection and spare parts, contact HYRIG: info@hyrig.com