| Model | Nominal Size | Max Pressure | Max Flow | Pilot Type | Mounting |
|---|---|---|---|---|---|
| WH32 | DN32 | 35 MPa | 1100 L/min | Hydraulic | ISO 4401-10 |
| WEH32 Valve | DN32 | 35 MPa | 1100 L/min | Solenoid | ISO 4401-10 |
| WH25 Valve | DN25 | 35 MPa | 650 L/min | Hydraulic | ISO 4401-08 |
Data source: Technical data table.
Text-based mounting parameters for the WH32:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-10 (CETOP 10) |
| Bolt Pattern | 6 x M20 threaded holes |
| Port Connections | A, B, P, T (Requires O-ring 42 x 3 mm) |
| Overall Length | Approx. 362 mm (Main valve) |
| Main Body Width | 164 mm |
The WH32 is controlled solely by external hydraulic pilot pressure. Designed for the most demanding high-flow applications, the main spool is shifted by hydraulic pressure and held in the center by springs or hydraulic pressure.
Available in spool types (A, B, C, D, E, G, H, J, L, M, P, Q, R, T, U, V, W, Y).
Options:
Replacing an old valve? Check:
Used in extreme high-flow environments such as large presses, heavy mining equipment, and large hydraulic power packs.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help identifying the correct control oil port connections? Contact our engineers with your system specifications.
Q: Does the WH32 require an electrical connection?
A: No, the WH32 is controlled purely by hydraulic pressure.
Q: What is the minimum pilot pressure for the WH32?
A: The minimum pilot pressure for internal supply is 1.8 MPa.
Q: Can I replace a WEH32 with a WH32?
A: Yes, the mounting interface is the same, but you must provide external pilot pressure lines for the WH32.
For WH32 hydraulic valve selection and spare parts, contact HYRIG: info@hyrig.com