XBSY Shear Pump FAQ | Installation, Oil, Alignment & Parts

2026-10-23 10:40

XBSY WJQ5×6J Shear Pump FAQ

What is the no-load running limit?

No-load running time cannot exceed 5 seconds. The pump must run filled with liquid slurry; otherwise the mechanical seal may be damaged.

What are the pulley alignment limits?

The axes of two pulleys must be parallel and the end surface error cannot exceed 2 mm; belts should be aligned and tightened; the electric motor must be mounted stably.

How often should bearing oil be changed?

Use 30# weight motor oil to the middle level of the dipstick. Oil should be changed every 90 days or 1000 hours.

What is the shaft radial runout limit?

When radial runout exceeds 0.05 mm, the shaft shall be replaced.

Can the suction pipeline have a throttle valve?

No. The suction line should not be throttled; a positive shut-off valve may be installed for pump removal and maintenance.

Can this pump be used on an active mud system?

No. The manual warns that the pump cannot be used on an active mud system because it will shear drill solids and barite, and these solids will damage the pump very quickly.

What is the impeller-to-protecting-plate clearance?

0.6 mm.

Where can I find WJQ5×6J part numbers?

The WJQ5×6J main pump and set drawing part numbers are listed on the XBSY WJQ5×6J parts and exploded view page.

Contact

For XBSY WJQ5×6J shear pump questions, contact HYRIG: info@hyrig.com

Name:
Message:
Verification code:
Submit