HYRIG can supply the YXL series priority valves. These valves are used with load sensing steering units to form a load sensing power steering control system, ensuring priority flow to the steering circuit even when system load or steering wheel speed varies.
The YXL priority valve is widely used in mobile hydraulic systems such as forklifts, wheel loaders, wheel cranes, tractors, and combine harvesters. It dynamically adjusts the flow to the steering unit based on the LS signal, guaranteeing reliable steering under all conditions.
Data source: Technical data table
| Parameter | YXL-F160L | YXL-F250F |
|---|---|---|
| Max Inlet Flow | 160 L/min | 250 L/min |
| Max Inlet Pressure | 20 MPa | 20 MPa |
| Relief Valve Setting | Customizable | Customizable |
| Port Type | Threaded | Flanged |
The YXL valve features a robust cast iron body with standard mounting dimensions.
| Dimension Item | Standard Value (mm) |
|---|---|
| Mounting | 2-Φ6 or 4-Φ11 holes (depends on model) |
| Port Sizes | M22x1.5, G3/4, 1-1/16-12UN (P, EF) |
| LS Port | M12x1.5 or 7/16-20UNF |
Not sure which YXL model matches your pump flow and steering unit? Tell us your system's pump capacity and LS signal type, and our engineers will confirm the correct valve.
Q: What is the function of a priority valve?
It ensures that the steering circuit always receives the required flow before hydraulic oil is directed to other auxiliary circuits, guaranteeing reliable steering.
Q: Can I use this with an open center steering unit?
No, the YXL series is designed for load sensing (LS) steering systems. For open center systems, an FLD flow divider valve should be used.
For YXL priority valve selection, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.