The 110103-500 is a 5,000 psi manual ball valve used as an upper inner blowout preventer on Varco top drives. Key specs: 3-1/4" bore, 4130 alloy steel body, NBR seals, 4-1/2" IF top connection, 3-1/2" IF bottom. Test pressure 7,500 psi. API Spec 7-1, API 16D. Temperature -20°C to +121°C.

Conatct For Details
DetailReview(0)Additional

Engineered for High-Pressure Drilling

The 110103-500 is a manual ball valve type inner blowout preventer built to withstand severe drilling conditions. This section provides a complete technical breakdown for engineers, procurement specialists, and maintenance crews.

Detailed Specifications

Pressure Ratings

  • Working Pressure: 5,000 psi (34.5 MPa)

  • Test Pressure (shell & seat): 7,500 psi (51.7 MPa)

  • Low-pressure test: 500 psi (3.4 MPa) per API 16D

Dimensional Data

  • Bore (full opening): 3-1/4" (82.6 mm)

  • Overall length: Standard API 16D length for top drive IBOP (consult drawing)

  • Top connection: 4-1/2" IF (Internal Flush) female – 4 TPI

  • Bottom connection: 3-1/2" IF male – 4 TPI

Materials

  • Body & end pieces: 4130 alloy steel, heat treated, normalized and tempered

  • Ball: Chrome-plated alloy steel, polished sealing surface

  • Seats: Thermoplastic with NBR energizer

  • Primary seals: NBR (nitrile rubber) – standard service

  • Stem seals: NBR O-rings

Operating Parameters

  • Max operating temperature: 121°C (250°F)

  • Min operating temperature: -20°C (-4°F)

  • Maximum recommended cycle rate: 10 full cycles per hour (intermittent)

  • Breakaway torque (dry): approx. 200-250 N·m (varies with pressure)

API Compliance

  • API Spec 7-1: Thread connections and dimensional interchangeability

  • API 16D: IBOP design, testing, and performance requirements

  • API Q1: Quality management system

Performance Characteristics

The 110103-500 uses a floating ball design with pressure-energized seats. When closed, differential pressure from below forces the ball against the upstream seat, creating a positive seal. The T-handle provides mechanical advantage for manual operation under pressure.

Testing Requirements (per API 16D)

TestPressureDurationAcceptance
Low-pressure seat test500 psi5 minNo visible leakage
High-pressure seat test5,000 psi5 minNo pressure drop
Shell test7,500 psi5 minNo structural leakage
Operational test0 psi3 cyclesSmooth open/close

Torque vs. Differential Pressure (Approximate)

Differential Pressure (psi)Operating Torque (N·m)
030
1,00080
2,500140
5,000220

Contact for Technical Data Package

Complete 2D/3D drawings, test certificates, and material traceability are available upon request.