| Model | Nominal Size | Max Pressure | Max Flow (L/min) | Feedback Type |
|---|---|---|---|---|
| 2FRE10 | DN10 | 21 MPa | 80 | Inductive Sensor |
| 2FRE16 | DN16 | 21 MPa | 160 | Inductive Sensor |
| 2FRE6 Valve | DN6 | 21 MPa | 25 | Inductive Sensor |
Data source: Technical data table.
Mounting parameters for the 2FRE10/16 valves:
| Parameter | Specification |
|---|---|
| Mounting Interface (DN10) | ISO 4401-05 (CETOP 5) |
| Mounting Interface (DN16) | ISO 4401-07 (CETOP 7) |
| Weight (DN10) | Approx. 6.0 kg |
| Weight (DN16) | Approx. 8.3 kg |
Similar to the 2FRE6, these valves use a proportional solenoid, a pressure compensator, and an inductive position sensor. The larger sizes are designed to handle higher flow rates while maintaining precise control. The pressure compensator ensures the flow remains constant regardless of load fluctuations.
`2FRE` + `Size (10/16)` + `40` + `Flow Range` + `Options`.
Example: `2FRE16-40/160L` = DN16, 160 L/min flow range.
Replacing an old valve? Check:
Used in large injection molding machines, heavy machine tools, and hydraulic presses for precise speed control.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help choosing the correct flow range or amplifier? Contact our engineers with your system specifications.
Q: What is the maximum flow rate for the 2FRE16?
A: The 2FRE16 supports a maximum flow rate of 160 L/min.
Q: What is the difference between the DN10 and DN16 sizes?
A: The DN16 size has a larger mounting interface and can handle twice the maximum flow rate (160 L/min) compared to the DN10 size (80 L/min).
Q: Which amplifier is required for these valves?
A: The VT-5004 series amplifier is designed for both the 2FRE10 and 2FRE16 valves.
For 2FRE10/16 proportional flow control valve selection and spare parts, contact HYRIG: info@hyrig.com