HYRIG can supply the 2FRE6 proportional flow control valve range and their spare parts. The 2FRE6 is a 2-way flow control valve with pressure compensation and an inductive position sensor. It is designed to control flow rate independently of pressure and temperature changes.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Valve Type: 2-Way Proportional Flow Control Valve
  • Nominal Size: DN6
  • Max Working Pressure: 21 MPa
  • Max Flow Rate: 25 L/min
  • Feedback: Inductive position sensor
  • Pressure Compensation: Integral

2FRE6 Specifications & Model Comparison

ModelNominal SizeMax PressureMax Flow (L/min)Feedback Type
2FRE6DN621 MPa25Inductive Sensor
2FRE10/16 ValveDN10/1621 MPa160Inductive Sensor
PQ10 ValveDN1014 MPa125Pressure & Flow

Data source: Technical data table.

Dimensions

Mounting parameters for the 2FRE6 valve:

ParameterSpecification
Mounting InterfaceISO 4401-03 (CETOP 3)
Bolt Pattern4 x M5 threaded holes (40.5 x 40.5 mm)
Port ConnectionsA, B, P, T (Requires O-ring 9.25 x 1.78 mm)
WeightApprox. 4.0 kg

Structure / Working Principle

The 2FRE6 uses a proportional solenoid to adjust the opening of a control throttle. A pressure compensator is connected upstream to maintain a constant pressure drop across the throttle, ensuring the flow rate remains constant regardless of load pressure. The inductive position sensor provides closed-loop feedback to the amplifier, ensuring the throttle opening precisely matches the command signal.

How to Order (Model Code)

`2FRE6` + `Control Type (A/B)` + `20` + `Flow Range` + `Options`.

  • Control Type: `A` (External control), `B` (Internal control).
  • Flow Range: `2QE` (2 L/min), `3Q` (3 L/min), `6Q` (6 L/min), `10Q` (10 L/min), `16Q` (16 L/min), `25Q` (25 L/min).

Example: `2FRE6B-20/16Q` = Internal control, 16 L/min flow range.

Cross-Reference & Replacement

Replacing an old valve? Check:

  1. Control Type: Ensure A or B type matches your circuit.
  2. Amplifier: Requires a closed-loop amplifier compatible with the 2FRE6 sensor (e.g., VT-5010).

Applications

Used in injection molding machines, machine tools, and testing equipment for precise and stable speed control.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Need help choosing the correct flow range or control type? Contact our engineers with your system specifications.

Frequently Asked Questions

Q: What is the maximum flow rate for the 2FRE6?
A: The 2FRE6 supports a maximum flow rate of 25 L/min.

Q: What is the difference between A and B control types?
A: A type uses external control pressure (port P), while B type uses internal control pressure to keep the pressure compensator closed until the valve is energized, preventing startup jump.

Q: Which amplifier is required for the 2FRE6?
A: The VT-5010 series amplifier is designed specifically for the 2FRE6.

Contact

For 2FRE6 proportional flow control valve selection and spare parts, contact HYRIG: info@hyrig.com

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit