| Model | Nominal Size | Max Pressure | Max Flow (L/min) | Control Type | Pressure Ranges |
|---|---|---|---|---|---|
| 3DREP6 | DN6 | 10 MPa | 15 | 3-Way | 1.6 / 2.5 / 4.5 MPa |
| DRE/DREM Valve | DN10 to DN32 | 31.5 MPa | 300 | Pilot-operated 2-way | 5 / 10 / 20 / 31.5 MPa |
Data source: Technical data table.
Mounting parameters for the 3DREP6 valve:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-03 (CETOP 3) |
| Bolt Pattern | 4 x M5 threaded holes (40.5 x 40.5 mm) |
| Port Connections | A, P, T, B (Requires O-ring 9.25 x 1.78 mm) |
| Weight | 1.5 kg (A or B type) / 2.6 kg (C type) |
The valve consists of a proportional solenoid and a pressure control spool. When the solenoid is energized, it pushes the control spool to connect port P to port A (or B), building up pressure. The pressure acts on the spool against the solenoid force until equilibrium is reached. If the pressure exceeds the setting, the spool moves to connect A (or B) to T, reducing the pressure. At rest, P is blocked and A/B are connected to T.
`3DREP6` + `Control Type (A/B/C)` + `10` + `Pressure Range` + `Voltage`.
Example: `3DREP6A-10/25Z4` = A-port control, 2.5 MPa range, DC 24V.
Replacing an old valve? Check:
Used as a pilot valve for 4WRZ proportional directional valves, or in low-pressure hydraulic circuits for precise pressure control.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help choosing the correct control type (A, B, C)? Contact our engineers with your system schematic.
Q: What is the maximum P port pressure for the 3DREP6?
A: The maximum P port pressure is 10 MPa. If higher, an upstream reducing valve is required.
Q: What is the function of the 3-way design?
A: The 3-way design allows the valve to both increase pressure (P to A) and decrease pressure (A to T) to maintain precise control.
Q: Can it be used as a pilot valve?
A: Yes, it is commonly used as the pilot valve for the 4WRZ series main valves.
For 3DREP6 proportional reducing valve selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.