HYRIG can supply the 3DREP6 proportional reducing valve range and their spare parts. The 3DREP6 is a direct-operated 3-way proportional pressure reducing valve. It converts an electrical signal into a proportional pressure signal to control the pressure and flow direction in a hydraulic circuit.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Valve Type: Direct-operated 3-way proportional pressure reducing valve
  • Nominal Size: DN6
  • Max Working Pressure: 10 MPa (P port)
  • Max Flow Rate: 15 L/min (at ΔP = 5 MPa)
  • Pressure Ranges: 1.6, 2.5, 4.5 MPa
  • Control Types: A-port, B-port, or A&B-port control

3DREP6 Specifications & Model Comparison

ModelNominal SizeMax PressureMax Flow (L/min)Control TypePressure Ranges
3DREP6DN610 MPa153-Way1.6 / 2.5 / 4.5 MPa
DRE/DREM ValveDN10 to DN3231.5 MPa300Pilot-operated 2-way5 / 10 / 20 / 31.5 MPa

Data source: Technical data table.

Dimensions

Mounting parameters for the 3DREP6 valve:

ParameterSpecification
Mounting InterfaceISO 4401-03 (CETOP 3)
Bolt Pattern4 x M5 threaded holes (40.5 x 40.5 mm)
Port ConnectionsA, P, T, B (Requires O-ring 9.25 x 1.78 mm)
Weight1.5 kg (A or B type) / 2.6 kg (C type)

Structure / Working Principle

The valve consists of a proportional solenoid and a pressure control spool. When the solenoid is energized, it pushes the control spool to connect port P to port A (or B), building up pressure. The pressure acts on the spool against the solenoid force until equilibrium is reached. If the pressure exceeds the setting, the spool moves to connect A (or B) to T, reducing the pressure. At rest, P is blocked and A/B are connected to T.

How to Order (Model Code)

`3DREP6` + `Control Type (A/B/C)` + `10` + `Pressure Range` + `Voltage`.

  • Control Type: `A` (A-port), `B` (B-port), `C` (A and B port).
  • Pressure Range: `16` (1.6 MPa), `25` (2.5 MPa), `45` (4.5 MPa).

Example: `3DREP6A-10/25Z4` = A-port control, 2.5 MPa range, DC 24V.

Cross-Reference & Replacement

Replacing an old valve? Check:

  1. Control Type: Ensure the valve controls the correct port (A, B, or both).
  2. Pilot Pressure: If the P port pressure exceeds 10 MPa, a reducing valve must be installed upstream.

Applications

Used as a pilot valve for 4WRZ proportional directional valves, or in low-pressure hydraulic circuits for precise pressure control.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Selection Support

Need help choosing the correct control type (A, B, C)? Contact our engineers with your system schematic.

Frequently Asked Questions

Q: What is the maximum P port pressure for the 3DREP6?
A: The maximum P port pressure is 10 MPa. If higher, an upstream reducing valve is required.

Q: What is the function of the 3-way design?
A: The 3-way design allows the valve to both increase pressure (P to A) and decrease pressure (A to T) to maintain precise control.

Q: Can it be used as a pilot valve?
A: Yes, it is commonly used as the pilot valve for the 4WRZ series main valves.

Contact

For 3DREP6 proportional reducing valve selection and spare parts, contact HYRIG: info@hyrig.com

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit