HYRIG can supply API 594 wafer check valves. This FAQ addresses common engineering and procurement questions regarding face-to-face categories, pressure rating, installation, and plate design.
Q: What is the difference between API 594 Type A and Type B?
Type A is short face-to-face (wafer or lug). Type B is long face-to-face, dimensionally equivalent to a flanged swing check. They are not interchangeable.
Q: Does a wafer check valve have its own pressure rating?
No. The pressure class belongs to the bolted flange assembly. The valve body seals compressed between the mating flanges, similar to a wafer butterfly valve.
Q: Can a wafer check valve be installed vertically?
Yes, with upward flow. Downward-flow vertical installation is not acceptable. Confirm the cracking pressure for vertical orientation.
Q: What happens if the gasket ID is too small?
The gasket protrudes into the flow path and can block the plate from opening or closing fully. Always verify the gasket ID against the valve bore.
Q: What is the difference between single-plate and dual-plate wafer check valves?
A single plate uses one disc with longer travel. A dual-plate design uses two spring-loaded half-plates with shorter travel, giving faster closure and lower water hammer risk.
Q: Can a wafer check valve be used for low-pressure gas?
Yes, with a soft spring selected for low cracking pressure. Standard springs may be too stiff for minimum flow conditions.
Q: What standards does the wafer check valve comply with?
Design to API 594 and API 6D, face-to-face to API 594, pressure-temperature ratings to ASME B16.34, and testing to API 598.
Q: What is the typical lead time?
Standard lead time is 4-6 weeks depending on size, class, material, and plate design.
For specific questions regarding your wafer check valve installation or selection, provide the line size, flange class, medium, and flow direction. Our engineering team will confirm the specification.
For more information on API 594 wafer check valves, contact HYRIG: info@hyrig.com