HYRIG can supply API 594 wafer check valves. Because the valve body sits compressed between two flanges without its own ends, installation centering and gasket selection determine whether the plate can open and close freely. This guide covers the installation checks that prevent the most common field failures.
| Installation Parameter | Requirement |
|---|---|
| Centering tolerance | Body OD centered within bolt circle |
| Gasket ID | Must be equal to or larger than valve bore |
| Flange face finish | 125–250 AARH |
| Bolt tightening | Star pattern, multiple passes |
| Orientation | Horizontal or vertical upward flow |
| Dimension | Standard |
|---|---|
| Face-to-face (Type A) | API 594 |
| Mating flange | ASME B16.5 / B16.47 |
| Gasket type | Spiral wound or ring joint |
The wafer check valve relies on the mating flanges to compress the body and create the seal. Unlike a flanged valve, there are no bolt holes on the valve body itself; the flange bolts pass around the body, not through it.
This means two installation variables directly affect valve function:
When installing a replacement wafer check valve:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. The gasket inside diameter must not obstruct plate movement; verify flange centering and clearance before bolting.
Q: What happens if the gasket ID is too small?
The gasket protrudes into the flow path and can block the plate from opening or closing fully. This can cause leakage, noise, or mechanical damage to the plate.
Q: How do I center a wafer check valve?
The body outer diameter should sit concentrically within the flange bolt circle. Hand-tighten the bolts, verify the body is centered, then torque in a star pattern.
Q: Can I reuse the old gasket?
No. Always use a new gasket. Old gaskets may be compressed, cracked, or contaminated, and cannot provide a reliable seal.
Q: Does the valve have a flow arrow?
Yes. The body is marked with a flow arrow. Confirm the arrow points in the direction of forward flow before bolting.
To confirm the correct gasket and installation procedure for your wafer check valve, provide the flange class, line size, and gasket type. Our engineers will verify the bore clearance and centering requirements.
For wafer check valve installation support, contact HYRIG: info@hyrig.com