HYRIG can supply the API 594 wafer check valve range. The wafer check valve is a non-return valve that fits compressed between two pipe flanges, with no ends of its own. It is available in single-plate and dual-plate designs, Class 150 and 300, in API 594 Type A short face-to-face dimensions.
| NPS | DN | L (mm) | D (mm) | D2 (mm) | D3 (mm) | Weight (kg) |
|---|---|---|---|---|---|---|
| 2 | 50 | 60 | 103 | 51 | 56 | 2 |
| 3 | 80 | 73 | 135 | 80 | 88 | 4 |
| 4 | 100 | 73 | 173 | 102 | 108 | 6 |
| 6 | 150 | 98 | 220 | 152 | 160 | 13 |
| 8 | 200 | 127 | 277 | 203 | 210 | 25 |
| 10 | 250 | 146 | 337 | 254 | 266 | 39 |
| 12 | 300 | 181 | 407 | 305 | 310 | 54 |
Data source: Technical data table.
| Dimension | Standard |
|---|---|
| Face-to-face (Type A) | API 594 |
| Mating flange drilling | ASME B16.5 / B16.47 |
| Pressure-temperature rating | ASME B16.34 (flange assembly) |
| Testing | API 598 |
The wafer check valve has a body that fits between two flanges. Forward flow opens the plate or plates; reverse flow or spring force closes them against the seat. Because the valve has no flanged ends, the pressure rating belongs to the bolted flange assembly, not to the loose valve body.
The single-plate design uses one disc that swings or lifts off the seat. It is compact and works in any orientation with spring assistance. The dual-plate design uses two D-shaped half-plates on a central hinge pin, each with its own spring. The shorter plate travel gives faster closure and lower water hammer risk, which is why dual-plate wafer checks are common on pump discharge with frequent stops.
Replacing a flanged swing check with a wafer check requires verification of four factors:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. The gasket inside diameter must not obstruct plate movement; verify flange centering and clearance before bolting.
Q: What is the difference between API 594 Type A and Type B?
Type A is short face-to-face (wafer or lug). Type B is long face-to-face, dimensionally equivalent to a flanged swing check. They are not interchangeable.
Q: Does a wafer check valve have its own pressure rating?
No. The pressure class belongs to the bolted flange assembly. The valve body seals compressed between the mating flanges.
Q: What is the difference between single-plate and dual-plate wafer check valves?
A single plate uses one disc with a longer travel. A dual-plate design uses two spring-loaded half-plates with shorter travel, giving faster closure and lower water hammer risk.
Q: Can a wafer check valve be installed vertically?
Yes, with upward flow. Downward-flow vertical installation is not acceptable.
Q: What is the typical lead time?
Standard lead time is 4-6 weeks depending on size, class, material, and plate design.
To confirm the correct plate design, face-to-face category, and spring for your line, provide the line size, flange class, medium, flow direction, and whether water hammer or low-pressure opening is a concern. Our engineering team will verify the API 594 Type A dimensions and installation clearance.
For API 594 wafer check valve selection, contact HYRIG: info@hyrig.com