Are you searching for a China-made API 610 pump suitable for tower bottom liquid applications?
This series includes VS1, VS2, VS5, VS6 models, strictly manufactured according to the latest API 610 (centrifugal pumps for petroleum, petrochemical, and natural gas industries) standard, engineered for pumping high‑temperature, high‑viscosity, and often solids‑laden liquids from the bottom of distillation towers, fractionators, strippers, and other process columns. Typical fluids include vacuum residue, atmospheric tower bottoms, cracker tar, heavy fuel oil, and various heavy hydrocarbon streams. These liquids are often at temperatures up to 350°C, may contain catalyst fines or coke particles, and have low NPSH available due to column elevation.
With vertical immersed design (eliminating suction piping), low NPSH inducers, high temperature materials, hardened wear components, and advanced sealing systems, our pumps provide safe, reliable, long‑life (≥30 years) operation for these demanding tower bottom services.
Full API 610 Compliance – Designed and manufactured per API 610 latest edition for VS1, VS2, VS5, and VS6 constructions. Passed strict dynamic balancing, hydrostatic, and high temperature testing. Design life ≥30 years, continuous trouble‑free operation ≥3 years.
Low NPSH for Tower Drawoff – Tower bottoms typically have limited liquid level (low NPSH available). All models are vertical, fully immersed pumps. Optional inducer on the first stage reduces NPSH required to as low as 0.5‑1.5 m, ensuring stable operation without cavitation.
High Temperature & Erosion Resistance – Wetted parts in Cr‑Mo steel (WC6/WC9, up to 350°C) or 304/316L stainless steel. Impellers and wear rings are nitrided or stellite‑hardfaced to resist abrasion from suspended solids. Hardened interstage bushings for multi‑stage models.
High Pressure, High Head Capabilities – VS1 (single‑stage diffuser) for large flow (50‑4600 m³/h) at low head (10‑120 m). VS2 (single‑stage volute) for medium head (30‑300 m). VS5 (single‑casing multi‑stage, up to 5 MPa, head up to 1000 m). VS6 (double‑casing multi‑stage, up to 15 MPa, head up to 1200+ m) for very high pressure pumping of heavy residues to downstream units.
Advanced Sealing for Hot, Heavy Liquids – API 682 mechanical seals with Plan 62 (steam quench) to prevent coking and hardening of heavy bottoms at seal faces. For hazardous or high‑pressure services, dual seals Plan 53B with barrier fluid are available. High temperature packing with steam injection is also an option.
Heavy‑Duty Bearings & Thrust Management – High‑load rolling or tilting‑pad thrust bearings (VS5/VS6) with forced oil lubrication and water cooling. Vibration monitoring per API 670. Rotor thrust balancing by balance drum or opposed impellers.
Vertical Design – Pump column is immersed directly into the tower bottom sump or a small external vessel, eliminating external suction piping and heat loss. Bearing housing and motor above grade.
Easy Maintenance – VS1/VS2 allow pull‑out of rotating element without removing the casing. VS5/VS6 require lifting the column but provide higher pressure containment.
Features: Vertical single‑case, diffuser type – large flow up to 4600 m³/h, head 10‑120 m, high hydraulic efficiency. Good for low NPSH with optional inducer.
Tower bottom applications: Atmospheric tower bottoms (low head transfer to storage or heat exchangers), vacuum tower sump drawoff at low head, large volume circulation of hot oil in refinery preheat trains.
Commonly searched as: large flow tower bottom pump / VS1 atmospheric bottoms pump.
Features: Vertical single‑case, volute type – flow 20‑1200 m³/h, head 30‑300 m, excellent anti‑cavitation.
Tower bottom applications: Medium head transfer of vacuum tower bottoms to coker feed, visbreaker feed, or asphalt blowing units; residue circulation with higher head than VS1.
Searches matched: medium head hot residue pump / VS2 tower bottom transfer pump.
Features: Vertical multi‑stage (single barrel casing), head up to 1000 m, working pressure up to 5.0 MPa. Equipped with low NPSH first stage.
Tower bottom applications: High head pumping of FCC main column bottoms to slurry oil downstream units; high pressure feed of heavy tower bottoms to hydrotreaters or hydrocrackers (moderate pressure); long distance transport of heavy residue from tower to storage.
Searches matched: multi‑stage high head tower bottom pump / VS5 residue charge pump.
Features: Vertical multi‑stage with inner stage casing inside an outer pressure‑containing barrel – head up to 1200+ m, working pressure up to 15 MPa (higher on request). Double casing provides safe containment of hazardous, high‑pressure, high‑temperature heavy liquids. Inducer first stage for very low NPSH.
Tower bottom applications: Ultra‑high pressure feed of tower bottoms to residue hydrocracking (RHC) units; high pressure injection into delayed coker; pumping very heavy, high‑temperature tar from ethylene cracker towers to fuel oil or storage.
Searches matched: double casing high pressure tower bottom pump / VS6 severe residue pump.
| Model | Flow (m³/h) | Head (m) | Max Temp (°C) | Working Pressure (MPa) | Stages |
|---|---|---|---|---|---|
| VS1 | 50–4600 | 10–120 | 350 | ≤2.0 | 1 |
| VS2 | 20–1200 | 30–300 | 350 | ≤3.0 | 1 |
| VS5 | 10–800* | up to 1000 | 350 | ≤5.0 | 2‑10 |
| VS6 | 10–800* | up to 1200+ | 350 | ≤15.0 (higher possible) | 4‑14 |
*Flow range for VS5/VS6 up to 800 m³/h typically; larger sizes on request.
| Component | Standard (Sweet, low solids) | High Temp + Abrasion Option | Notes |
|---|---|---|---|
| Casing (VS1/VS2) | WCB carbon steel (≤250°C) | WC6/WC9 (Cr‑Mo) for 350°C | |
| Outer barrel (VS6) | Forged low alloy (F22) | 304L or 316L | High pressure |
| Inner stage casing (VS5/VS6) | Cr‑Mo or CF8M | Nitrided Cr‑Mo | |
| Impeller | Cr‑Mo steel | Nitrided + stellite tip | Hardened for solids |
| Wear rings / interstage bushings | 17‑4 PH | Stellite 6/12 | Replaceable |
| Shaft | AISI 4140/4340 | 17‑4 PH H1150 | Higher torque |
| Bolting | B7 | B7M / L7M | NACE optional |
| Seal | API 682 Plan 62 (steam quench) | Plan 53B dual (for hazard) | Faces: SiC vs carbon |
| Bearing | High‑load rolling / tilt‑pad | Forced oil + water cooler | |
| Gaskets | Spiral wound graphite 316L |
For sour tower bottoms (containing H₂S), NACE MR0175 compliance with hardness control.
Q: Which API 610 pump model is best for high pressure feed of vacuum tower bottoms to a hydrocracker (12 MPa, 350°C)?
A: VS6 double‑casing multi‑stage barrel pump. It handles up to 15 MPa and high temperature with Cr‑Mo internals and steam quench seals.
Q: Which model is suitable for large flow atmospheric tower bottoms (4000 m³/h, 50 m head) with low NPSH?
A: VS1 diffuser pump – large flow capacity, low NPSH, head up to 120 m. Use inducer if tower level is very low.
Q: Can VS2 handle medium head (200 m) residues containing catalyst fines?
A: Yes. Specify hardened impeller (nitrided/stellite), increased clearances, and Plan 62 seals (steam quench). Provide wear rings.
Q: What is the advantage of VS6 over VS5 for tower bottoms?
A: VS6 has an outer pressure barrel (double casing), allowing much higher working pressures (15 MPa vs 5 MPa). It is required for high‑pressure injection into residue upgrading units.
Q: How do you prevent coking of heavy tower bottoms on the seal faces?
A: API 682 Plan 62 with continuous low‑pressure steam quench sweeps the seal chamber, preventing degradation products from accumulating. For very high pressures, Plan 53B with barrier fluid plus Plan 62.
Q: Are these pumps made in China?
A: Yes, we are a Chinese manufacturer certified to API 610, with extensive references in tower bottom pumping for refineries and petrochemical plants.
Q: What is the design life and MTBF?
A: Design life ≥30 years, continuous trouble‑free operation ≥3 years for tower bottom service with proper maintenance.
Vertical immersed design – no suction piping, low NPSH.
High temperature up to 350°C – Cr‑Mo steel, centerline mounting.
Erosion resistant – hardened impellers, stellite wear rings.
Pressure range – VS1/VS2 (low‑medium head), VS5 (5 MPa), VS6 (15 MPa).
Anti‑coking sealing – steam quench Plan 62 as standard.
China competitive pricing without compromising API 610 quality.
For inquiries, model selection, or technical support, please provide: tower bottom fluid composition, temperature (°C), viscosity (cSt), solids content (wt%), flow (m³/h), head (m), required discharge pressure (MPa), available NPSH, and column liquid level. Our tower bottom specialists will recommend the optimal API 610 pump (VS1/VS2/VS5/VS6) with correct stage count, material hardening, and sealing.
Email: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.