HYRIG can supply the API lubricated plug valve range. The valve uses an inverted pressure balance design and a sealant injection system to maintain a tight seal and reduce operating torque.
Conatct For Details
DetailReview(0)Additional

API Lubricated Plug Valve

HYRIG can supply the API lubricated plug valve range. The valve uses an inverted pressure balance design and a sealant injection system to maintain a tight seal and reduce operating torque. It is suited for high-pressure gas, dry service, and applications where soft PTFE sleeves cannot be used.

Key Facts

  • Design standard: API 599, API 6D
  • Pressure class: Class 150 / Class 300
  • Size range: NPS 1/2-14 (DN 15-350)
  • Construction type: Inverted Pressure Balance
  • Sealing mechanism: Sealant injection (lubrication)
  • Operation: Wrench, handwheel, or gear operation
  • Body materials: ASTM A216 WCB, A351 CF8, CF8M
  • Testing: API 598

Key Specifications

NPSDNClass 150 L (mm)Class 150 H (mm)Class 150 Wt (kg)Class 300 L (mm)Class 300 H (mm)Class 300 Wt (kg)
1/2151081801014018012
1251271851416518516
2501782152121621524
3802032703328327036
41002293004830530061
615026736598403365130
8200292400125419400190
12300356510230502510380

Data source: Technical data table.

Dimensions

DimensionStandard
Face-to-faceASME B16.10 / API 6D
Flanged endsASME B16.5
Butt weld endsASME B16.25
Pressure-temperature ratingAPI 599

Structure and Working Principle

The lubricated plug valve features a tapered plug rotating inside a metal body. The sealing is maintained by injecting a special sealant (lubricant) into the grooves between the plug and the body. This sealant displaces the process fluid and creates a hydraulic seal.

The inverted pressure balance design means that line pressure acts on the bottom of the plug, pushing it upward against the cover. This reduces the friction between the plug and the body, significantly lowering the operating torque compared to a standard plug valve. It also prevents the plug from jamming under high pressure.

Because the sealant can be injected while the valve is in service, the lubricated plug valve is highly reliable in dry gas service or high-pressure applications where a soft PTFE sleeve would extrude or degrade.

Cross-Reference and Replacement

Replacing a lubricated plug valve requires checking:

  1. Sealant System: Confirm whether the valve has a sealant injection fitting and check the sealant type required for your medium.
  2. Face-to-Face Dimension: Verify the L dimension against the piping gap.
  3. Actuation: Lubricated plug valves have higher initial torque than sleeve type. Verify the wrench, handwheel, or gear operator sizing.
  4. Temperature Limit: The metal body and sealant allow higher operating temperatures than the soft PTFE sleeve design.

Applications

  • High-Pressure Gas: Natural gas transmission and distribution lines.
  • Dry Service: Where a soft PTFE sleeve would dry out and fail.
  • Dirty Service: The sealant injection can flush out minor debris that enters the seating area.
  • High-Temperature Service: Where the temperature exceeds the limit of PTFE sleeves.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation. The sealant injection system must be maintained per the manufacturer's schedule to ensure sealing integrity.

Frequently Asked Questions

Q: What is the difference between a sleeve type and a lubricated plug valve?

A sleeve type uses a PTFE liner for soft sealing. A lubricated type uses sealant injection to maintain the seal, making it suitable for high-pressure and dry gas service.

Q: How often does the sealant need to be injected?

The injection frequency depends on the service conditions. For clean gas, it may be once a year. For dirty or high-temperature service, it may be more frequent. Follow the maintenance schedule.

Q: Can a lubricated plug valve be used for slurries?

It is not recommended for abrasive slurries because the sealant can be washed away or contaminated. For slurries, a sleeve type or a different valve design is preferred.

Q: What is the typical lead time?

Standard lead time is 4 to 6 weeks depending on size, class, and material.

Selection Support

To confirm the correct lubricated plug valve for your line, provide the medium, operating pressure, temperature, and whether a sealant injection system is required. Our engineering team will verify the configuration.

Contact

For API lubricated plug valve selection, contact HYRIG: info@hyrig.com