The API 610 OH2 (Overhung Type 2) aromatics pump is the standard for handling benzene, toluene, xylene (BTX), mixed aromatics, and heavy aromatic fractions in refineries, petrochemical plants, and chemical terminals. Aromatics are hazardous volatile organic compounds – toxic, carcinogenic (benzene is Group 1), highly flammable with low flash point, and moderately prone to cavitation. In addition, aromatics are strong solvents that swell and degrade conventional elastomers (NBR, EPDM). The centerline‑mounted casing (OH2, never OH1) provides thermal stability and pipe load resistance for continuous chemical service.
Structural Definition – OH2 per API 610
Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).
Centerline‑mounted – casing supported from the centreline flange.
Overhung impeller – mounted at the shaft end, outside the bearing housing.
Radially split volute casing.
Closed impeller.
Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.
Heavy‑duty bearing housing with temperature and vibration monitoring.
Applicable Media – Aromatics (BTX & Related)
Fully applicable:
Benzene (C₆H₆), toluene (C₇H₈), xylene (C₈H₁₀) – ortho, meta, para
Mixed aromatics, BTX fraction, heavy aromatics (C9+)
Reformer aromatics, pyrolysis aromatics, hydrodealkylation products
Unit feed, reflux, product transfer, tank farm storage, truck/rail loading, pipeline export
Not applicable (use other pump types):
High solids, abrasive particles, heavy residues
Strong acids/bases (unless special alloys)
Media & Operating Characteristics – Aromatics (Comparable to Naphtha/Gasoline)
Aromatics have volatility and cavitation risk similar to naphtha and gasoline, with additional toxicity and solvent hazards.
| Property | Benzene | Toluene | Xylene | Naphtha/Gasoline (for reference) |
|---|---|---|---|---|
| Boiling point | 80°C | 110°C | 138–144°C | 30–200°C |
| Vapour pressure at 20°C | 0.1 bar | 0.03 bar | 0.01 bar | 0.3–0.7 bar |
| Flash point | –11°C | 4°C | 25–30°C | –40 to –20°C |
| Cavitation risk | Moderate to high | Moderate | Low to moderate | High |
| Toxicity | Carcinogenic (Group 1) | Harmful | Harmful | Low |
| Solvent effect on elastomers | Severe swelling | Severe swelling | Severe swelling | Moderate |
Performance Boundaries (Aromatics Duty)
Flow: 10 – 2500 m³/h (typical 20 – 1500 m³/h)
Head: 20 – 300 m (single‑stage)
Design pressure: Typically Class 300 or 600 (5.0–11.0 MPa / 50–110 bar)
Temperature: –20°C to +180°C (ambient to warm; no heating/tracing required)
Speed: 1480 or 2980 rpm
NPSH requirement: NPSHa ≥ NPSHr + 1.0–1.5 m – similar to naphtha/gasoline. Inducer optional, recommended for low NPSHa applications (e.g., from atmospheric storage).
Mandatory Design Configuration – Aromatics OH2 (Same Severity as Naphtha/Gasoline)
1. Hydraulic Design – Moderate to High NPSH Margin
Closed impeller with low‑NPSH inlet design.
NPSHa margin of 1.5 m preferred for benzene (most volatile aromatics).
Inducer recommended when pumping benzene or toluene from atmospheric tanks with limited submergence.
2. Mechanical Sealing – API 682 (Dual Seal Mandatory with Special Elastomers)
Aromatics are toxic, volatile, and aggressive to standard seal elastomers. Dual mechanical seals with FFKM (perfluoroelastomer) or PTFE seals are mandatory.
Mandatory: Dual mechanical seal (pressurised).
Preferred plans:
Plan 53A (pressurised dual seal with external barrier fluid reservoir) – most common. Barrier fluid (typically compatible non‑hydrocarbon fluid) at 2–3 bar above seal chamber pressure.
Plan 54 (circulated barrier fluid system) – for heavy duty or high‑temperature aromatics.
Elastomer requirement (critical): FFKM (Kalrez / Chemraz) or FEP‑encapsulated O‑rings – standard NBR, FKM (Viton), or EPDM will swell, soften, and fail rapidly in aromatics. Only perfluoroelastomers or PTFE seals are acceptable.
Seal face materials: Silicon carbide vs. silicon carbide or tungsten carbide.
Prohibited: Single mechanical seal (any Plan 11/21/23/32). Packed gland – absolutely forbidden.
3. Material Combination (Copper‑Free, Corrosion‑Resistant)
Pure aromatics are non‑corrosive to carbon steel, but trace chlorides or sulfur (in pyrolysis/coker aromatics) may require stainless steel. Copper‑free construction is mandatory per APIRP 2003.
Casing: WCB carbon steel (standard for pure BTX); 304L or 316L stainless steel for mixed/industrial aromatics containing trace chlorides or sulfur.
Impeller / Wear rings: 316L stainless steel or duplex – resists trace corrosion.
Shaft: High‑strength alloy steel (4140/42CrMo) or 316L – large diameter, low deflection. No copper, brass, or bronze.
NACE MR0175: Required only for aromatics from coker/pyrolysis units containing H₂S.
4. Explosion‑Proof & Safety – T6 Required
Aromatics have very low flash points (benzene –11°C, toluene 4°C). Explosion protection must match naphtha/gasoline – T6 is strongly recommended.
Motor & pump assembly: ATEX / IECEx certified for Zone 1 or Zone 2.
Gas group: IIB or IIC (certain aromatics mixtures may lean toward IIC).
Temperature class: T6 (85°C auto‑ignition protection) – mandated for benzene and toluene by many facilities; T4 is not sufficient.
Toxic containment: Sealless pump designs (canned motor or magnetic drive) are sometimes specified, but OH2 with dual seals and barrier fluid is more common for higher flows/pressures.
Leak detection: Seal pot pressure/level alarms; fixed gas detectors for LEL and toxic (benzene) monitoring.
Anti‑static features: Shaft grounding, flange earthing straps, conductive gaskets.
5. Bearing & Lubrication
Heavy‑duty angular contact thrust bearings.
Lubrication: Oil mist (preferred for chemical plants), oil ring, or forced lube.
Bearing temperature RTD and vibration monitoring (API 670) – good practice for safety‑critical aromatic services.
6. Support & Construction
Centerline support (OH2) – handles temperature swings (ambient to 180°C).
Heavy‑duty bearing housing – supports 2980 rpm operation.
Back pull‑out design – allows seal replacement without breaking pipework – essential for toxic service where seal leakage must be avoided.
Why OH2 (Not OH1 or BB) for Aromatics
| Pump Type | Suitability for Aromatics | Reason |
|---|---|---|
| OH2 (centerline) | Mandatory | Thermal stability, high pressure rating, back pull‑out. Only acceptable OH type. |
| OH1 (foot‑mounted) | Prohibited | Poor thermal alignment, lower nozzle load rating – fails chemical plant specs. |
| BB2/BB3 (between‑bearing) | Over‑specified | Higher cost, larger footprint; only justified for flow >2500 m³/h or head >300 m. |
Comparison – Aromatics vs. Naphtha vs. Gasoline vs. LPG vs. Diesel (OH2)
| Feature | LPG OH2 | Condensate OH2 | Aromatics OH2 | Naphtha/Gasoline OH2 | Diesel OH2 |
|---|---|---|---|---|---|
| Cavitation risk | Extreme | Very high | Moderate to high | High | Low |
| NPSH margin required | ≥1.5–2.0 m | ≥1.5–2.0 m | ≥1.0–1.5 m | ≥1.0–1.5 m | ≥0.5–1.0 m |
| Inducer | Mandatory | Recommended | Optional | Often required | Rare |
| Sealing type | Dual seal (53A) | Dual seal (53A) | Dual seal (53A/54) | Dual seal | Single seal |
| Seal elastomer | Standard FKM | Standard FKM | FFKM mandatory | Standard FKM | Standard FKM |
| Toxicity | Low | Low | High (carcinogenic) | Low to moderate | Low |
| Explosion class | T6 | T6 | T6 | T4/T6 | T4 |
| Material | WCB + 12Cr | WCB/NACE + 12Cr | WCB/316L | WCB + 12Cr | WCB + 12Cr |
| Special hazard | High pressure, flash | H₂S, flash | Toxicity, solvent swelling | Flash | None |
Why Refineries and Chemical Plants Specify OH2 for Aromatics
Toxic containment: Dual mechanical seals (Plan 53A) with barrier fluid provide zero leakage to atmosphere, protecting operators from benzene exposure – a regulatory requirement under OSHA, REACH, and local EPA rules.
Elastomer compatibility: Mandatory FFKM seals prevent the rapid swelling and seal failure seen with standard FKM or NBR in aromatic service.
Cavitation protection: The generous NPSH margin prevents vaporisation, which would otherwise release toxic vapour through the seal.
Safety integrity: Ex d IIB T6 motors and full grounding meet the highest electrical safety standards for flammable, toxic liquids.
Maintainability: Back pull‑out design allows seal and bearing inspection without breaking pipework – critical for minimising operator exposure to hazardous aromatics.
For complete technical datasheets, sizing assistance, or a quotation for any API 610 OH2 aromatics pump (benzene, toluene, xylene, mixed aromatics), please contact info@hyrig.com. We respond within 24 hours.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.