The API 610 OH2 condensate pump is a horizontal, overhung, centerline‑mounted single‑stage end suction centrifugal pump designed for natural gas condensate, field condensate, and light hydrocarbon liquids (natural gasoline). Condensate volatility and cavitation risk rank between LPG and naphtha – requiring stringent design. Mandatory features: high NPSH margin (≥1.5–2.0 m), inducer (recommended), API 682 dual mechanical seal (Plan 53A/54), Ex d IIB T6 explosion protection, copper‑free materials, and NACE MR0175 for sour condensate. WCB casing, 12Cr/316L impeller. Back pull‑out design. Contact info@hyrig.com

Conatct For Details
DetailReview(0)Additional

The API 610 OH2 (Overhung Type 2) condensate pump is the industry standard for handling natural gas condensate, field condensate, and associated light hydrocarbon liquids (often called natural gasoline). Condensate is an ultra‑light hydrocarbon mixture – predominantly pentanes (C5+), hexanes, and natural gasoline – that separates from raw natural gas during production. Its volatility and vapour pressure sit between those of LPG (propane/butane) and naphtha (C5–C10). This creates a very high cavitation risk, low flash point, and severe safety requirements, demanding pump design nearly as robust as LPG but without the same extreme pressure class. The centerline‑mounted casing (OH2, never OH1) ensures thermal stability and pipe load resistance for continuous oilfield, gas plant, and terminal service.

Structural Definition – OH2 per API 610

  • Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).

  • Centerline‑mounted – casing supported from the centreline flange.

  • Overhung impeller – mounted at the shaft end, outside the bearing housing.

  • Radially split volute casing.

  • Closed impeller with optional inducer.

  • Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.

  • Heavy‑duty bearing housing with temperature and vibration monitoring.

Applicable Media – Condensate & Related Light Hydrocarbons

Fully applicable:

  • Natural gas condensate (raw, stabilised, or debutanised)

  • Field condensate from gas wells, associated gas, or condensate reservoirs

  • Natural gasoline, light hydrocarbon liquids (C5+)

  • Oilfield condensate (often containing trace H₂S and salts)

  • Gas plant condensate, tank condensate, NGL (natural gas liquids) – pentanes plus

  • Truck/rail loading, pipeline transfer, sphere‑to‑sphere movement, process feed

Not applicable (use other pump types):

  • Heavy residues, high‑viscosity oils, asphaltenic crudes

  • High solids (sand, catalyst fines)

Media & Operating Characteristics – Condensate (Between LPG and Naphtha)

Condensate volatility is higher than naphtha but lower than LPG. Its cavitation risk is very high, requiring generous NPSH margins and often an inducer.

PropertyLPGCondensateNaphtha / Gasoline
Boiling point range–42 to –0.5°C25–120°C30–200°C
Vapour pressure at 20°C7–9 bar0.5–1.5 bar0.3–0.7 bar
Flash point–104°C–45 to –20°C–40 to –20°C
Cavitation riskExtremeVery highHigh
NPSH margin required≥1.5–2.0 m≥1.5–2.0 m≥1.0–1.5 m
InducerMandatoryRecommendedOften required
Typical oilfield/plant serviceRefrigeration, gas processingCondensate transfer, exportRefinery feed, blending
H₂S contentSometimes (sour LPG)Common (sour condensate)Occasional (sour naphtha)

Performance Boundaries (Condensate Duty)

  • Flow: 10 – 2500 m³/h (typical 20 – 1500 m³/h)

  • Head: 20 – 300 m (single‑stage)

  • Design pressure: Typically Class 300 or 600 (5.0–11.0 MPa / 50–110 bar). Class 300 is common for stabilized condensate; Class 600 for raw, high‑vapour‑pressure condensate.

  • Temperature: –30°C to +120°C (ambient to warm condensate; no heating/tracing required). Low‑temperature impact testing may be needed for winter conditions below –30°C.

  • Speed: 1480 or 2980 rpm (1480 rpm preferred to improve NPSH margin)

  • NPSH requirement: NPSHa ≥ NPSHr + 1.5–2.0 m – mandatory. Inducer is strongly recommended. This margin exceeds naphtha and matches LPG specifications.

Mandatory Design Configuration – Condensate OH2 (Naphtha/Gasoline‑Equivalent Severity)

1. Hydraulic Design – High NPSH Margin & Inducer Recommended

  • Inducer (axial flow stage) is recommended, often mandatory for low‑NPSHa applications (e.g., from atmospheric tanks or downstream of separators with limited submergence).

  • Inducer increases pump NPSHr by 1–2 metres, preventing flashing at suction.

  • Closed impeller with low‑NPSH inlet design. NPSHa margin of 2.0 metres preferred for raw, high‑vapour‑pressure condensate.

  • Avoid high suction velocity – use larger suction flange size.

2. Mechanical Sealing – API 682 (Dual Seal Mandatory)
Condensate is highly volatile and flammable, often containing H₂S. Single seals are not acceptable.

  • Mandatory: Dual mechanical seal (pressurised).

  • Preferred plans:

    • Plan 53A (pressurised dual seal with external reservoir) – most common. Barrier fluid pressure ≥2 bar above seal chamber pressure.

    • Plan 54 (circulated barrier fluid system) – for heavy duty or high‑temperature condensate.

    • Plan 52 (unpressurised dual seal with catch tank) – may be used for clean, non‑sour condensate where leakage to flare is allowed, but pressurised Plan 53A is strongly preferred.

  • Seal face materials: Silicon carbide vs. silicon carbide or tungsten carbide – must tolerate momentary flashing.

  • Prohibited: Single mechanical seal (any Plan 11/21/23/32). Packed gland – absolutely forbidden.

3. Material Combination (Copper‑Free, NACE MR0175 for Sour Condensate)

Condensate often contains H₂S and chlorides (from formation water), requiring NACE MR0175 compliance. Copper‑free construction is mandatory per APIRP 2003.

  • Casing: WCB carbon steel (NACE MR0175 compliant for H₂S); LCC for low temperature (–30°C and below).

  • Impeller / Wear rings: 12% chrome (CA6NM) or 316L stainless steel – both acceptable for sour service.

  • Shaft: High‑strength alloy steel (4140/42CrMo) – large diameter, low deflection. No copper, brass, or bronze in any wetted or non‑wetted parts (including bearing cages, fasteners, seal gland plates).

  • NACE MR0175 compliance: Mandatory for all pressure‑containing parts when condensate contains H₂S (common in many gas fields).

4. Explosion‑Proof & Safety – Highest Level (T6)

Condensate's very low flash point (often below –20°C) demands explosion protection equal to gasoline or naphtha. Temperature class T6 is recommended.

  • Motor & pump assembly: ATEX / IECEx certified for Zone 1 or Zone 2.

  • Gas group: IIB.

  • Temperature class: T6 (85°C auto‑ignition protection) – T4 (135°C) is minimum but T6 is widely specified for condensate.

  • Anti‑static features: Shaft grounding, flange earthing straps, conductive gaskets.

  • Bearing housing isolation: Labyrinth seals to prevent hydrocarbon vapour ingress.

  • Leak detection: Seal pot level/pressure alarms; fixed gas detection in pump enclosure for LEL monitoring.

5. Bearing & Lubrication

  • Heavy‑duty angular contact thrust bearings (moderate to high axial thrust due to low density fluid at 2980 rpm).

  • Lubrication: Oil mist (preferred for gas plants), oil ring with constant level, or forced lube. Bearings must be copper‑free (steel cages).

  • Bearing temperature RTD and vibration monitoring (API 670) – good practice for condensate due to high cavitation risk.

6. Support & Construction

  • Centerline support (OH2) – even thermal expansion for temperature swings from ambient up to 120°C.

  • Heavy‑duty bearing housing – supports high speeds (2980 rpm common).

  • Back pull‑out design – allows seal and inducer/impeller inspection without breaking pipework – critical for remote oilfield locations where maintenance access is limited.

Why OH2 (Not OH1 or BB) for Condensate

Pump TypeSuitability for CondensateReason
OH2 (centerline)MandatoryThermal stability, high pressure rating, back pull‑out. Only acceptable OH type for condensate.
OH1 (foot‑mounted)ProhibitedCannot withstand pipe strain or thermal distortion; fails oilfield and gas plant specs.
BB2/BB3 (between‑bearing)Over‑specifiedHigher cost, larger footprint; only justified for flow >2500 m³/h or head >300 m.

Comparison – Condensate vs. LPG vs. Naphtha vs. Gasoline vs. Diesel (OH2)

FeatureLPG OH2Condensate OH2Naphtha/Gasoline OH2Diesel OH2
Boiling point at atm–42 to –0.5°C25–120°C30–200°C170–370°C
Vapour pressure at 20°C7–9 bar0.5–1.5 bar0.3–0.7 barVery low
Cavitation riskExtremeVery highHighLow to moderate
NPSH margin required≥1.5–2.0 m≥1.5–2.0 m≥1.0–1.5 m≥0.5–1.0 m
InducerMandatoryRecommendedOften requiredRare
Sealing typeDual seal mandatoryDual seal mandatoryDual seal mandatorySingle seal preferred
Pressure class600# / 900#300# / 600#300# / 600#150# / 300#
Explosion classEx d IIB T6Ex d IIB T6T4/T6T4
NACE MR0175Required for sour LPGRequired for sour condensateRequired for sour naphthaOptional
Copper‑freeMandatoryMandatoryMandatoryRecommended
Heating/tracingNoNoNoNo

Why Oilfields, Gas Plants, and Terminals Specify OH2 for Condensate

  • Very high cavitation protection: The large NPSH margin, low suction losses, and recommended inducer prevent flashing – the most common cause of condensate pump failure.

  • Dual seal reliability: Pressurised dual seals (Plan 53A) with barrier fluid ensure zero emission to atmosphere, even if inner seal wear occurs from trace sand or H₂S corrosion.

  • Sour service readiness: NACE MR0175 materials and dual seals handle the H₂S and chlorides often present in field condensate.

  • Stringent safety: Ex d IIB T6 motors, grounding, and leak detection meet oilfield safety codes (e.g., API RP 505, NFPA 70).

  • Maintainability: Back pull‑out design is vital for remote gas plants where quick seal replacement without lifting heavy pipework saves days of downtime.