The API 610 OH2 LPG pump is a horizontal, overhung, centerline‑mounted single‑stage end suction centrifugal pump designed for liquid petroleum gas – propane, butane, and mixed LPG. LPG has extremely low boiling point (as low as –42°C for propane) and very high vapour pressure, making it the most cavitation‑prone hydrocarbon. Mandatory design features: inducer, NPSHa margin of 1.5–2.0 m, API 682 dual mechanical seal (Plan 52/53A/54), Ex d IIB T6 explosion protection, copper‑free materials (WCB casing, 12Cr/316L impeller). High‑pressure construction (Class 600/900). Back pull‑out design. Contact info@hyrig.com

Conatct For Details
DetailReview(0)Additional

The API 610 OH2 (Overhung Type 2) LPG pump is the refinery, gas processing, and terminal standard for handling liquid petroleum gas – including propane, butane, and mixed propane‑butane. LPG is one of the most challenging pumped hydrocarbons due to its extremely low boiling point (propane boils at –42°C at atmospheric pressure) and correspondingly high vapour pressure. Any pressure drop at the pump suction can cause instantaneous flashing, leading to severe cavitation, vibration, seal failure, and loss of prime. Therefore, the LPG pump design must be the most robust among all OH2 hydrocarbon pumps – exceeding even gasoline and naphtha in cavitation protection and safety requirements.

Structural Definition – OH2 per API 610

  • Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).

  • Centerline‑mounted – casing supported from the centreline flange (OH2, never foot‑mounted OH1).

  • Overhung impeller – mounted at the shaft end, outside the bearing housing.

  • Radially split volute casing.

  • Closed impeller with integral inducer (mandatory for most LPG services).

  • Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.

  • Heavy‑duty bearing housing with temperature and vibration monitoring.

Applicable Media – LPG & Related Light Hydrocarbons

Fully applicable:

  • Propane (C3), butane (C4), mixed propane‑butane (LPG)

  • Commercial LPG, auto LPG, refinery LPG

  • Saturated light hydrocarbons (C3–C4)

  • Unit feed, sphere‑to‑sphere transfer, truck/rail loading, vaporiser feed, pipeline export

Not applicable (use other pump types):

  • High solids content, heavy residues, high‑viscosity liquids

  • Strongly corrosive media (unless special alloys)

Media & Operating Characteristics – LPG (Most Severe Among OH2 Hydrocarbons)

LPG properties represent the extreme end of the hydrocarbon volatility and cavitation risk spectrum:

PropertyLPGNaphtha / GasolineKeroseneDiesel
Boiling point at atm–42°C (propane) to –0.5°C (butane)30–200°C150–250°C170–370°C
Vapour pressure at 20°C7–9 bar (propane)0.3–0.7 barVery lowVery low
Flash point–104°C (propane)–40 to –20°C38–70°C55–80°C
Cavitation riskExtreme (highest)Very highModerateLow to moderate
ViscosityVery low (0.1–0.3 cP)0.4–0.8 cP1–2 cP2–10 cP
NPSH margin required≥1.5–2.0 m≥1.0–1.5 m≥1.0 m≥0.5–1.0 m
InducerMandatoryOften requiredOptionalRare
Sealing typeDual seal mandatoryDual seal mandatoryDual for jet fuel; single for refinedSingle seal preferred
Pressure class600# / 900#300# / 600#300# / 600#150# / 300#

Performance Boundaries (LPG Duty – Highest Pressure, Highest Cavitation Margin)

  • Flow: 10 – 2000 m³/h (typical 20 – 1000 m³/h)

  • Head: 20 – 300 m (single‑stage)

  • Design pressure: 6.0 – 15.0 MPa (60–150 bar) – typically Class 600 (11 MPa) or Class 900 (15 MPa). LPG requires higher pressure ratings than gasoline due to high vapour pressure and pump differential.

  • Temperature: –50°C to +80°C (ambient to warm LPG; cryogenic LPG at –50°C requires low‑temperature carbon steel LCC or impact‑tested materials)

  • Speed: 1480 or 2980 rpm (1480 rpm preferred for low NPSH operation, but 2980 rpm may be used with large inducer)

  • NPSH requirement (critical – highest standard): NPSHa ≥ NPSHr + 1.5–2.0 m – this is mandatory. Inducer is not optional – it is a standard feature for LPG pumps to raise NPSHr to an acceptable level.

Mandatory Design Configuration – LPG OH2 (Most Stringent Among All Hydrocarbons)

1. Hydraulic Design – Inducer Mandatory, High NPSH Margin

  • Inducer (axial flow stage) is mandatory – no LPG pump shall be supplied without an inducer unless NPSHa is exceptionally high (>10 m) and approved by end user.

  • Inducer raises pump NPSHr by 1–2 metres, preventing flashing at suction.

  • Closed impeller with polished inlet surfaces to minimise cavitation erosion.

  • NPSHa margin of 2.0 metres is strongly recommended for propane‑rich LPG.

2. Mechanical Sealing – API 682 (Dual Seal Mandatory)
LPG’s extreme volatility and low flash point (propane –104°C) mean that any seal leakage will instantly flash to flammable gas. Single seals are prohibited.

  • Mandatory: Dual mechanical seal (pressurised or unpressurised).

  • Preferred plans:

    • Plan 53A (pressurised dual seal with external barrier fluid reservoir) – most common. Barrier fluid (usually clean glycol or compatible oil) is maintained at 2–3 bar above seal chamber pressure.

    • Plan 54 (circulated barrier fluid system) – for continuous LPG service with high heat generation.

    • Plan 52 (unpressurised dual seal with catch tank/vapour detector) – acceptable for some clean LPG where leakage to flare is allowed.

  • Seal face materials: Silicon carbide vs. silicon carbide or tungsten carbide – must resist dry running if momentary flashing occurs.

  • Prohibited: Single mechanical seal (any Plan 11/21/23/32). Packed gland – absolutely forbidden.

3. Material Combination (Copper‑Free, Low‑Temperature Capable)

Copper‑free construction is mandatory (per APIRP 2003). Low‑temperature impact testing is required for LPG service below –20°C.

  • Casing: WCB carbon steel for temperatures above –20°C; LCC or LC3 for cryogenic LPG down to –50°C (impact tested per ASTM A370).

  • Impeller / Wear rings: 12% chrome (CA6NM) or 316L stainless steel – both suitable down to –50°C.

  • Shaft: High‑strength alloy steel (4140/42CrMo) – large diameter, rigid. No copper, brass, or bronze.

  • NACE MR0175: Required for LPG containing H₂S (sour LPG from refinery off‑gas).

4. Explosion‑Proof & Safety – Highest Level (T6)

LPG’s auto‑ignition temperature is low, and gas group is IIB. Temperature class T6 is widely specified for LPG.

  • Motor & pump assembly: ATEX / IECEx certified for Zone 1 or Zone 2 (hazardous area).

  • Gas group: IIB (propane, butane).

  • Temperature class: T6 (85°C auto‑ignition protection) – mandatory for many LPG installations; T4 is not sufficient.

  • Anti‑static features: Shaft grounding, flange earthing straps, conductive gaskets.

  • Bearing housing isolation: Labyrinth seals with purge option (nitrogen) to prevent LPG vapour accumulation.

  • Leak detection: Seal pot level and pressure alarms; gas detector in pump enclosure.

5. Bearing & Lubrication

  • Heavy‑duty angular contact thrust bearings (high axial thrust from high pressure).

  • Lubrication: Oil mist (preferred for LPG units), oil ring with constant level oiler, or forced lube. Bearings must be copper‑free (steel cages).

  • Bearing temperature RTD and vibration monitoring (API 670) – mandatory for LPG due to high consequence of failure.

6. High‑Pressure Construction (Class 600/900)

  • Flanges: Class 600 or 900, raised face or RTJ (ring joint) for higher leak tightness.

  • Casing hydrotest pressure: 1.5 × design pressure.

  • Gaskets: Spiral wound with inner ring (for higher pressure containment).

Why OH2 (Not OH1 or BB) for LPG

Pump TypeSuitability for LPGReason
OH2 (centerline)MandatoryThermal stability, high pressure rating, back pull‑out. Only acceptable OH type for high pressure LPG.
OH1 (foot‑mounted)ProhibitedCannot withstand high nozzle loads, poor thermal alignment, lower pressure rating.
BB2/BB3 (between‑bearing)Over‑specifiedHigher cost and footprint; only justified for flow >2000 m³/h or head >300 m.

Comparison – LPG vs. Naphtha vs. Gasoline vs. Kerosene vs. Diesel vs. Crude (OH2)

FeatureLPG OH2Naphtha/Gasoline OH2Kerosene OH2Diesel OH2Crude OH2
Boiling point at atm–42 to –0.5°C30–200°C150–250°C170–370°C>100°C
Vapour pressure at 20°C7–9 bar0.3–0.7 barVery lowVery lowNegligible
Cavitation riskExtremeVery highModerateLowLow
NPSH margin required≥1.5–2.0 m≥1.0–1.5 m≥1.0 m≥0.5–1.0 m≥0.5–1.0 m
InducerMandatoryOften requiredOptionalRareNot required
Sealing typeDual seal mandatory (53A/54)Dual seal mandatoryDual for jet fuelSingle seal preferredDual for sour crude
Pressure class600# / 900#300# / 600#300# / 600#150# / 300#300# / 600#
Explosion classEx d IIB T6T4/T6T4/T6T4T4
Low temp capabilityRequired (–50°C)Not typicallyNot typicallyNot typicallyNot required
Copper‑freeMandatoryMandatoryRecommendedRecommendedNot required

Why Refineries and Terminals Specify OH2 for LPG

  • Highest cavitation protection: The mandatory inducer and large NPSH margin prevent flashing – the single most common failure mode for LPG pumps.

  • Dual seal reliability: Pressurised dual seals (Plan 53A) with barrier fluid ensure zero LPG leakage to atmosphere, even if the inner seal fails.

  • High pressure integrity: Class 600/900 construction withstands full LPG vapour pressure at ambient temperatures without leaks.

  • Stringent safety: Ex d IIB T6 motors, grounding, and leak detection meet the strictest international LPG codes (NFPA 58, EN 1473, etc.).

  • Maintainability: Back pull‑out design allows seal and inducer/impeller inspection without breaking pipework – critical for minimising downtime in high‑volume LPG loading terminals.