API 610 OH2 Naphtha Pump – Centerline‑Mounted Overhung Pump for Light Hydrocarbon Naphtha Services

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
The API 610 OH2 naphtha pump is a horizontal, overhung, centerline‑mounted single‑stage end suction centrifugal pump built for naphtha services – straight‑run naphtha, hydrotreated naphtha, light/heavy naphtha, and cracked naphtha. Naphtha shares gasoline's high volatility, very low flash point, and high cavitation risk. Mandatory features: high NPSH margin (NPSHa ≥ NPSHr + 1.5 m), optional inducer, API 682 dual mechanical seal (Plan 53A or 54), Ex d IIB T6 explosion‑proof rating, copper‑free construction (WCB + 12Cr/316L). Back pull‑out design for easy maintenance. Contact info@hyrig.com

Conatct For Details
DetailReview(0)Additional

The API 610 OH2 (Overhung Type 2) naphtha pump is the refinery standard for handling naphtha – a light hydrocarbon fraction with volatility, flash point, and cavitation risk nearly identical to gasoline. Naphtha includes straight‑run naphtha, hydrotreated naphtha, light naphtha, heavy naphtha, and cracked naphtha (ethylene plant feed). Because of its extreme volatility and low flash point, naphtha pumps must meet the same rigorous safety and design requirements as gasoline pumps, exceeding those for kerosene, diesel, or crude oil. The centerline‑mounted casing (OH2, never foot‑mounted OH1) ensures thermal stability and pipe strain resistance for continuous refinery operation.

Structural Definition – OH2 per API 610

  • Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).

  • Centerline‑mounted – casing supported from the centreline flange.

  • Overhung impeller – mounted at the shaft end, outside the bearing housing.

  • Radially split volute casing.

  • Closed impeller (low NPSH design; optional inducer).

  • Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.

  • Heavy‑duty bearing housing with temperature and vibration monitoring.

Applicable Media – Naphtha & Related Light Hydrocarbons

Fully applicable:

  • Straight‑run naphtha, hydrotreated naphtha

  • Light naphtha (C5–C6), heavy naphtha (C7–C10)

  • Cracked naphtha (ethylene cracker feed, pyrolysis naphtha)

  • Reformer feed, isomerisation feed, blending naphtha

  • Unit feed, reflux, tank farm transfer, truck/rail loading, pipeline export

Not applicable (use other pump types):

  • High coke fines or abrasive particles

  • Heavy residues, asphalt, high‑viscosity oils

Media & Operating Characteristics – Naphtha (Gasoline‑Level Severity)

Naphtha properties closely match gasoline, making it one of the most demanding refinery products for pump design:

PropertyNaphthaGasolineKeroseneDiesel
VolatilityVery highVery highModerateLow
Flash point–40 to –20°C (extremely flammable)≤ –40°C38–70°C55–80°C
ViscosityVery low (0.4–0.8 cP)Very low (0.3–1 cP)Low (1–2 cP)Low to moderate (2–10 cP)
Cavitation riskVery highVery highModerateModerate to low
NPSH margin required≥1.0–1.5 m≥1.0–1.5 m≥1.0 m≥0.5–1.0 m
Inducer needOften required for low NPSHaOften requiredOptionalRare
Copper‑freeMandatoryMandatoryRecommendedRecommended
SealingDual seal mandatoryDual seal mandatoryDual for jet fuel; single for refinedSingle preferred
Explosion classEx d IIB T6Ex d IIB T4/T6Ex d IIB T4/T6Ex d IIB T4

Performance Boundaries (Naphtha Duty)

  • Flow: 10 – 2500 m³/h (typical 20 – 1500 m³/h)

  • Head: 20 – 300 m (single‑stage)

  • Design pressure: Up to 5.0 MPa (50 bar) – typically Class 150/300; Class 600 for high‑pressure units (e.g., reformer feed)

  • Temperature: –20°C to +160°C (ambient to warm naphtha; no heating required)

  • Speed: 1480 or 2980 rpm (2980 rpm common for compact pumps)

  • NPSH requirement (critical): NPSHa ≥ NPSHr + 1.0–1.5 m. Inducer is strongly recommended when NPSHa is limited (e.g., from atmospheric storage with high vapour pressure naphtha). Margin of 1.5 m is preferred for cracked naphtha which contains light ends.

Mandatory Design Configuration – Naphtha OH2 (Same Severity as Gasoline)

1. Hydraulic Design – High Cavitation Margin

  • Closed impeller with optimised low‑NPSH inlet geometry.

  • Inducer (axial flow stage): Highly recommended for most naphtha services, especially when pumping from buffer tanks or where NPSHa is limited below 3–4 metres. Prevents vaporisation, vibration, and loss of prime.

  • Large suction nozzle diameter to reduce inlet velocity and improve NPSHr.

  • NPSHa margin of 1.5 m is the industry best practice for naphtha.

2. Mechanical Sealing – API 682 (Mandatory Dual Seal)
Naphtha is volatile, low‑flash, and highly flammable – single seals are prohibited. Only dual mechanical seals are acceptable.

  • Mandatory: Dual mechanical seal (pressurised or unpressurised).

  • Preferred plans:

    • Plan 53A (pressurised dual seal with external reservoir) – most common for naphtha. Barrier fluid at higher pressure than process fluid ensures zero leakage to atmosphere.

    • Plan 54 (pressurised dual seal with external circulation system) – for high vapour pressure naphtha or where process pressure is very high.

    • Plan 52 (unpressurised dual seal with catch tank) – may be used for some clean naphtha, but pressurised systems are preferred.

  • Prohibited: Single mechanical seal (Plan 11/21/23/32) – unacceptable leakage risk for naphtha. Packed gland – absolutely forbidden.

3. Material Combination (Copper‑Free, Anti‑Static)

Copper‑free construction is mandatory for naphtha to prevent catalytic gum formation and static discharge (per APIRP 2003, NACE RP0178, and refiner internal specs).

  • Casing: WCB carbon steel (standard); LCC for low temperature (winter ambient or cryogenic naphtha).

  • Impeller / Wear rings: 12% chrome (CA6NM) or 316L stainless steel – corrosion resistant, non‑sparking.

  • Shaft: High‑strength alloy steel (4140/42CrMo) – large diameter, rigid, low deflection. No copper, brass, or bronze in any component (including bearing cages, fasteners, seal gland plates).

  • NACE MR0175: Required for naphtha containing H₂S (sour naphtha from coker or untreated straight‑run).

4. Explosion‑Proof & Safety – Highest Level

Naphtha's very low flash point demands the highest explosion protection (same as gasoline – T6 is recommended).

  • Motor & pump assembly: ATEX / IECEx certified for hazardous area (Zone 1 or Zone 2).

  • Gas group: IIB (naphtha hydrocarbons).

  • Temperature class: T6 (85°C auto‑ignition protection) is recommended for naphtha; T4 (135°C) is minimum but many refineries specify T6 for light ends.

  • Anti‑static features: Shaft and casing grounding, flange earthing straps, conductive gaskets.

  • Bearing housing isolation: Non‑contact labyrinth seals to prevent hydrocarbon vapour ingress.

  • Seal leak detection: Dual seal barrier fluid pressure and level monitoring (low point alarms).

5. Bearing & Lubrication

  • Heavy‑duty angular contact thrust bearings (high axial thrust from high‑speed operation of low‑density fluids).

  • Lubrication: Oil mist (preferred for light hydrocarbon units), oil ring, or forced lube for high power. Bearing temperature RTD and vibration monitoring (API 670).

  • Bearing isolators must be copper‑free.

6. Support & Construction

  • Centerline support (OH2) – even thermal expansion, essential for naphtha's wide temperature swings (ambient to 160°C).

  • Heavy‑duty bearing housing – supports high speeds (2980 rpm common).

  • Back pull‑out design – allows seal replacement without removing casing from piping – critical for naphtha service where seal integrity inspections are frequent.

Why OH2 (Not OH1 or BB) for Naphtha

Pump TypeSuitability for NaphthaReason
OH2 (centerline)MandatoryThermal stability, pipe load capacity, back pull‑out. Only compliant choice for naphtha.
OH1 (foot‑mounted)ProhibitedPoor thermal alignment, lower nozzle load rating – fails refinery specifications for light hydrocarbons.
BB2/BB3 (between‑bearing)Over‑specifiedHigher cost, larger footprint; only justified for flow >2500 m³/h or head >300 m.

Comparison – Naphtha vs. Gasoline vs. Kerosene vs. Diesel vs. Crude (OH2)

FeatureNaphtha OH2Gasoline OH2Kerosene OH2Diesel OH2Crude OH2
VolatilityVery highVery highModerateLowVery low
Flash point–40 to –20°C≤ –40°C38–70°C55–80°CVaries
Cavitation riskVery highVery highModerateModerateLow
NPSH margin required≥1.0–1.5 m≥1.0–1.5 m≥1.0 m≥0.5–1.0 m≥0.5–1.0 m
InducerOften requiredOften requiredOptionalOptionalNot required
Sealing typeDual seal mandatory (Plan 53A/54)Dual seal mandatoryDual for jet fuel; single for refinedSingle seal (Plan 11) for clean dieselDual for sour crude
Explosion classEx d IIB T6Ex d IIB T4/T6Ex d IIB T4/T6Ex d IIB T4Ex d IIB T4
Copper‑freeMandatoryMandatoryRecommendedRecommendedNot required
Heating/tracingNoNoNoNoYes for waxy crude
MaterialWCB + 12Cr/316LWCB + 12Cr/316LWCB + 12Cr/316LWCB + 12CrDuplex / NACE alloys
Typical speed2980 rpm2980 rpm2980 rpm1480 or 2980 rpm1480 rpm

Why Refineries Specify OH2 for Naphtha

  • Severity matching gasoline: Naphtha and gasoline are the two most volatile, highest‑risk hydrocarbon streams in a refinery. The OH2 naphtha pump uses identical safety principles: dual seals, high NPSH margin, T6 explosion class, copper‑free materials.

  • Prohibited shortcuts: No single seals, no OH1 mounting, no copper alloys – naphtha specifications are explicit and non‑negotiable.

  • Cavitation prevention: The high NPSH margin and optional inducer prevent vapour formation at pump suction, which would otherwise cause severe vibration, seal damage, and hazardous release.

  • Reliability for continuous operation: Centerline support and heavy bearings ensure 3+ years continuous run – meeting refinery turnaround cycles.

  • Back pull‑out maintenance: Seal replacement (mandatory dual seal) is quick and safe without breaking pipe flanges.

For complete technical datasheets, sizing assistance, or a quotation for any API 610 OH2 naphtha pump (light naphtha, heavy naphtha, hydrotreated, cracked), please contact info@hyrig.com. We respond within 24 hours.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit