The API 610 OH2 (Overhung Type 2) kerosene pump is the refinery standard for handling kerosene, jet fuel (Jet A1), aviation kerosene, lamp kerosene, and kerosene middle distillates. Kerosene occupies a unique position in the hydrocarbon spectrum – more volatile than diesel, less volatile than gasoline, with a flash point typically between 38°C and 70°C. This demands a pump that balances safety, reliability, and cost‑effectiveness. The centerline‑mounted casing (OH2, not foot‑mounted OH1) provides thermal stability and resistance to pipe strain, essential for continuous refinery operation.
Structural Definition – OH2 per API 610
Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).
Centerline‑mounted – casing supported from the centreline flange.
Overhung impeller – mounted at the shaft end, outside the bearing housing.
Radially split volute casing.
Closed impeller.
Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.
Heavy‑duty bearing housing with temperature and vibration monitoring.
Applicable Media – Kerosene, Jet Fuel & Related Distillates
Fully applicable:
Aviation kerosene (Jet A1, Jet A, JP‑8)
Refined kerosene, lamp kerosene
Straight‑run kerosene, hydrotreated kerosene
Kerosene middle distillate fractions
Unit draw‑off, reflux, tank farm transfer, truck/rail loading, pipeline export
Not applicable (use other pump types):
High content of coke fines, abrasive particles, heavy residues
Strong corrosive media (strong acids, bases)
Media & Operating Characteristics – Unique to Kerosene
Kerosene properties fall between gasoline and diesel:
| Property | Gasoline | Kerosene / Jet Fuel | Diesel |
|---|---|---|---|
| Viscosity | Very low (0.3–1 cP) | Low (1–2 cP) | Low to moderate (2–10 cP) |
| Volatility / vapour pressure | Very high | Moderate | Low to moderate |
| Flash point | ≤ –40°C | 38–70°C (Jet A1 min 38°C) | 55–80°C |
| Cavitation risk | Very high | Moderate (less than gasoline) | Moderate to low |
| Material sensitivity | Copper‑free mandatory | Copper‑free strongly recommended | Copper‑free recommended |
| Typical sealing requirement | Dual seal (Plan 53/54) | Dual for jet fuel; single for refined kerosene | Single seal preferred |
Performance Boundaries (Kerosene Duty)
Flow: 20 – 2500 m³/h (typical 30 – 1500 m³/h)
Head: 20 – 250 m (single‑stage)
Design pressure: Up to 5.0 MPa (50 bar) – typically Class 150/300; Class 600 for high‑pressure services
Temperature: –20°C to +170°C (ambient to warm kerosene; no heating required)
Speed: 1480 or 2980 rpm (both common)
NPSH requirement: NPSHa ≥ NPSHr + 1.0 m – moderate requirement; more than diesel, less than gasoline. Inducer optional for low NPSHa.
Key Design Configuration – Kerosene OH2 Standard
1. Hydraulic Design & Cavitation
Closed impeller with optimised inlet geometry for moderate NPSH.
NPSHa margin of 1.0 m is recommended – kerosene is more volatile than diesel and can cavitate under marginal conditions.
Replaceable wear rings for service life when handling trace fines.
Inducer typically not required unless NPSHa is unusually low (e.g., from atmospheric storage with high vapour pressure).
2. Mechanical Sealing – API 682 (Critical for Jet Fuel)
Kerosene volatility and flammability demand careful seal selection:
Refined kerosene (low volatility, clean): Single mechanical seal with API Plan 11 (self‑flush from pump discharge) or Plan 21 (cooled flush) – acceptable for lamp kerosene or stable non‑volatile grades.
Jet fuel (aviation kerosene, Jet A1) and volatile kerosene: Dual mechanical seal (pressurised) with Plan 53A is strongly recommended. Jet fuel has lower flash point and higher safety requirements – a single seal may be considered inadequate by many refinery and airport fuel specifications.
Sour kerosene (containing H₂S): Dual seal Plan 53A plus NACE MR0175 materials.
Prohibited: Packed gland seals – unsafe for any kerosene service.
3. Material Combination (Kerosene Standard)
Copper‑free construction is strongly recommended for kerosene, especially jet fuel, to prevent gum formation and static discharge.
Casing: WCB carbon steel (standard); LCC for low‑temperature ambient applications.
Impeller / Wear rings: 12% chrome (CA6NM) or 316L stainless steel – corrosion resistant, good for trace chlorides.
Shaft: High‑strength alloy steel (4140/42CrMo) – high rigidity, low deflection.
Copper‑free requirement: Mandatory for jet fuel (per ASTM / API / DEF STAN specifications); strongly recommended for all kerosene services.
NACE MR0175: Required only for sour kerosene (e.g., untreated straight‑run or coker kerosene with H₂S).
4. Explosion‑Proof & Safety
Kerosene flash point (38–70°C) is higher than gasoline but still combustible in refinery electrical area classification.
Motor & pump assembly: ATEX / IECEx certified for hazardous area (Zone 1 or Zone 2).
Gas group: IIB (typical kerosene hydrocarbons).
Temperature class: T4 (135°C) is typical; T6 (85°C) may be specified for jet fuel facilities with stricter safety limits.
Anti‑static features: Shaft and casing grounding; flange earthing straps.
Bearing housing isolation: Labyrinth seals prevent hydrocarbon vapour ingress.
5. Bearing & Lubrication
Heavy‑duty angular contact thrust bearings (suitable for moderate axial thrust of kerosene).
Lubrication: Oil mist (preferred for continuous refinery units), oil ring with constant level oiler, or forced lube for high‑speed high‑power pumps.
Bearing temperature RTD and vibration monitoring (API 670).
6. Support & Construction
Centerline support (OH2) – even thermal expansion, handles pipe strain.
Heavy‑duty bearing housing – supports high‑speed operation (2980 rpm common for kerosene pumps).
Back pull‑out design – allows seal and bearing replacement without removing casing from piping – critical for minimising downtime in continuous service.
Why OH2 (Not OH1 or BB) for Kerosene
| Pump Type | Suitability for Kerosene | Reason |
|---|---|---|
| OH2 (centerline) | Optimal | Thermal stability, pipe load capacity, back pull‑out. Standard refinery kerosene pump. |
| OH1 (foot‑mounted) | Not allowed | Poor thermal alignment, lower nozzle load rating, not compliant with refinery specifications. |
| BB2/BB3 (between‑bearing) | Over‑specified | Higher cost, larger footprint; only justified for flow >2500 m³/h or head >250 m. |
Comparison – Gasoline OH2 vs. Kerosene OH2 vs. Diesel OH2 vs. Crude OH2
| Feature | Gasoline OH2 | Kerosene OH2 | Diesel OH2 | Crude OH2 |
|---|---|---|---|---|
| Volatility | Very high | Moderate | Low | Very low |
| Flash point | ≤ –40°C | 38–70°C | 55–80°C | Varies (often >60°C) |
| Cavitation risk | Very high | Moderate | Moderate | Low |
| NPSH margin required | ≥1.0–1.5 m | ≥1.0 m | ≥0.5–1.0 m | ≥0.5–1.0 m |
| Inducer | Often needed | Optional (rare) | Optional (rare) | Not required |
| Sealing type | Dual seal mandatory (Plan 53/54) | Dual for jet fuel (Plan 53A); single for refined | Single seal (Plan 11) for clean; dual for sour | Dual seal for sour crude |
| Explosion class | Ex d IIB T4/T6 | Ex d IIB T4/T6 | Ex d IIB T4 | Ex d IIB T4 |
| Copper‑free | Mandatory | Mandatory (jet fuel) / recommended | Recommended | Not required |
| Heating/tracing | No | No | No | Yes for waxy crude |
| Material upgrade | WCB + 12Cr/316L | WCB + 12Cr/316L | WCB + 12Cr | Duplex / NACE alloys |
| Typical speed | 2980 rpm | 2980 rpm (common) | 1480 or 2980 rpm | 1480 rpm |
Why Refineries Choose OH2 for Kerosene
Balanced design: Moderate NPSH margins and sealing requirements keep costs lower than gasoline pumps, while still meeting safety standards higher than diesel.
Jet fuel compliance: Optional dual seals and copper‑free materials meet ASTM, DEF STAN, and international jet fuel specification (including API 610 compliance).
Reliability: Centerline support and heavy bearings ensure 3+ years continuous operation – matches refinery turnaround cycles.
Maintainability: Back pull‑out design allows seal replacement without breaking pipe flanges – critical for kerosene service where seal integrity is paramount.
For complete technical datasheets, sizing assistance, or a quotation for any API 610 OH2 kerosene pump (including Jet A1, aviation kerosene, lamp kerosene), please contact info@hyrig.com. We respond within 24 hours.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.